Chapter 2: Installation
Operating Notes
When setting the control parameters on the HDX6800
+
B2/C2 and
HDX6800
+
B4/C4, observe the following:
•
If you make changes to certain parameters, other related parameters
may also be affected. See the section
B4/C4 Control Parameters” on page 32
for more
information.
•
When you change a parameter, the effect is immediate. However,
the module requires up to 20 seconds to save the latest change.
After 20 seconds, the new settings are saved and will be restored if
the module loses power and must be restarted.
•
When you set the
Factory Recall
parameter to
Yes
, the module
takes several seconds to reset all of the parameters to their default
settings.
•
The manufacturer recommends that you terminate any unused
coaxial output connectors with a 75
Ω
terminator.
See the following topics for more operational information:
•
“Audio Output Channel Status” on page 25
•
“Input Channel V-Bit Feedback (InxxVbitFb)” on page 25
•
“Demux Group Control (Grp1-4 Ctrl)” on page 26
•
“Output Audio Rate” on page 26
•