10
DA-S/SR/H/HR6802
+
DL Installation and Operation Manual
Copyright © 2009, Harris Corporation
Chapter 2: Installation and Operation
Preliminary—Contents are proprietary and confidential. Do not photocopy or distribute.
Setting Remotely Controlled Parameters
Table 2-3
describes parameters that are accessible remotely. Select remote
control mode by setting the J1 jumper to “Remote.” See your CCS control
software application manual or online help for more information on setting and
monitoring these parameters remotely.
Legend
Bold
option=Indicates that this is the default setting for the parameter.
[RO]=Indicates that parameters are read-only/feedback, and cannot be used to
select controls.
All parameters clip unless otherwise noted.
Recalling Default Parameter Settings
You cannot recall default parameter settings for DA-S/SR/H/HR6802
+
DL
modules.
Table 2-3.
DA-S/SR/H/HR6802
+
DL Remotely Controlled Parameters
Name
Range
Description
Signal Present [RO]
• No
• Yes
Indicates if input is present or not
Slew Rate
• Auto
• SD
• HD
Sets the output slew rate control
Serial Number
String
Displays the module's unique
identifier
License Key
String
Activates options
Locked Data Rate
[RO]
• Unknown
• 270 Mb/s
• Bypass Mode
• 1.485 Gb/s HD
• 2.97 Gb/s HD
Displays the data rate to which the
module is locked
Reclocking Mode
• Auto
• 270 Mb/s
• Bypass Mode
• 1.485 Gb/s HD
• 2.97 Gb/s HD
Displays the data rate to which the
module is forced to lock
Loss of Input Alarm
•
Disable
• Enable
Enables/disables Loss of Input alarm
Loss of Lock Alarm
•
Disable
• Enable
Enables/disables Loss of Lock alarm