8
DA-S/SR/H/HR6802
+
DL Installation and Operation Manual
Copyright © 2009, Harris Corporation
Chapter 2: Installation and Operation
Preliminary—Contents are proprietary and confidential. Do not photocopy or distribute.
Operation
Operating Notes
When you change a control parameter on a DA-S/SR/H/HR6802
+
DL module,
the effect is immediate. However, the module requires up to 20 seconds to save
the latest change. After 20 seconds, the new settings are saved and will be
restored if the module loses power and must be restarted.
Understanding Parameter Types
Most module parameters are adjustable, and can be set via a CCS software
application (see
“Setting Remotely Controlled Parameters” on page 10
and
“Recalling Default Parameter Settings” on page 10
). However, there are some
parameters that are considered “read-only” and cannot be changed. Indicated by
the abbreviation “
[RO]
,” these parameters provide status and feedback
information only.
Harris recommends that you use the available 6800
+
software control options
(serial/local or Ethernet/remote) to aid in viewing, setting, and confirming
parameter values.
Adjustable Parameters
Two types of adjustable parameters can be changed.
Numerical
parameters
require you to select a value within a numerical range.
Selectable
parameters
require you to select a specific option. Both numerical and selectable parameter
changes are immediate. Use the available 6800
+
software controls (serial
/
local
or Ethernet
/
remote network) to view and monitor parameter selections.
Read-Only Parameters
These parameters provide status and feedback information only. They are
represented by LEDs on the front of the module’s card edge. See
Figure 2-2 on
page 11
and
Figure 2-3 on page 12
for the location of these LEDs.
Summary of Contents for DA-H6802+DL