Imagine ADC-A12C31 Installation And Operation Manual Download Page 36

 

 

 

 

ADC-A12C31 Operator’s Handbook Rev. A   

 

 

P. 35 

 

 

 

Displayed time [local] is off a small amount. 

 
Possible reasons/solutions: 
1.

 

Perception/recognition response time. The average human ability to visually perceive and 
recognize time synchronization and/or instantaneous change between two visually separated 
systems is limited due to the movement of the eyes and the delayed response to process the 
data.  To reduce this effect:  

 

Place a digital display adjacent to the clock you are trying to verify the time on.   

 

View the clocks from a position that will avoid eye movements.   

 

Ensure that both clocks are locked to an accurate time code reference.  

 

Ensure that both units have the same offset settings for time zone and/or DST.   

2.

 

ADC-Set configuration utility’s screen display is a GUI (Graphical User Interface) that is not being 
run at the highest priority level for the system. There will likely be a delay in processing the data 
and updating the screen, therefore it should not be considered an accurate reference.   

3.

 

Ensure that you are not using Drop-Frame SMPTE time code. Drop-Frame time code is not 
supported. Accurate time cannot be guaranteed with drop-frame time code. 

4.

 

The clock hands have been incorrectly calibrated with either the calibration buttons or ADC-Set 
configuration utility. See the calibration procedure for details on how to recalibrate the hands. 

 

DST is not properly negotiated. 

The date shown in the status window of ADC-Set configuration utility is always 01/01/2000. 
 
Possible reasons/solutions: 
1.

 

Your time code reference is not providing date/year information. The DST adjustment will not 
work unless valid date information is provided. Verify that your time code reference has either 
date encoding to the SMPTE standard for SMPTE time code or year/date encoding to the IEEE 
1344 specification for IRIG-B/B1 time code. 

2.

 

The TC control DIP switches S2-1 and S2-2 have both been set to off and/or the time code date 
encoding has been disabled in the ADC-Set configuration utility. 

3.

 

Your time code reference already provides the DST adjustment. The DST adjustment in the ADC-
A12C31 should be disabled. 

4.

 

You have disabled the DST setting or the incorrect DST setting was enabled. The ADC-A12C31 has 
DIP switches for enabling various modes of DST or disabling the DST option. In addition to the DIP 
switches, the ADC-Set configuration utility may be used to set the DST settings as well as all 
configuration settings of the clock. If the ADC-Set configuration utility is used, it will over-ride the 
DIP switch settings. 

 
The clock hands are not moving and the red status LED is off. 

 
Possible Reasons/solutions: 
1.

 

The clock does not have power applied. 

2.

 

The Run/Set switch is in the SET position or the ADC-Set configuration utility is being used. 

3.

 

The internal power supply or the motor/motor drive has failed. 
 

 

There are no user serviceable parts inside the ADC-A12C31 analog clock. 
Please contact Imagine Communications Corporation if you require servicing or repair. 

 

 

Summary of Contents for ADC-A12C31

Page 1: ...Delivering the Moment ADC A12C31 Master Clock Revision A P061 0024 Installation and Operation Manual...

Page 2: ...time or an unknown time in the future This publication does not in any way warrant description accuracy or guarantee the use for the product to which it refers Imagine Communications reserves the righ...

Page 3: ...Environment 14 Status LED 14 Correction Behavior 14 Hand Position 15 Time Zone Offsets 15 Daylight Saving Time 15 Pre 2007 Standard U S A and Canada 16 Post 2006 Standard U S A and Canada 16 EU Standa...

Page 4: ...tery Circuit 33 Maintenance Free Rechargeable Battery 33 Operating Storage Temperature Humidity 33 Size and Weight 33 Troubleshooting 34 The time is incorrect 34 Not displaying the correct local time...

Page 5: ...ADC A12C31 Operator s Handbook Rev A P 4 This page intentionally left blank...

Page 6: ...1 U S A All rights reserved This publication supersedes all previous releases No part of this documentation may be reproduced in any form or by any means or used to make any derivative work without pe...

Page 7: ...00 3 2 2000 Harmonic Current Emission EN61000 3 3 1995 A1 2001 Voltage Fluctuations Flicker Low voltage directive 2006 95 EC Tested and Conforms to the following Safety standards EN60950 1 2001 Safety...

Page 8: ...r the WEEE directive except that Category 8 Medical Devices and Category 9 Monitoring and Control Instruments which are under WEEE are excluded from the RoHS directive The time display product ADC A12...

Page 9: ...oding using the USB port and ADC Set Clock Time Code Display USB Configuration Utility i e Windows software application The time code reference must provide date encoding in the control bits fields to...

Page 10: ...mmunications Corporation warranty may be void as a result of the failure to respect the precautions stated above Only qualified persons are authorized to carry out maintenance on this device Read this...

Page 11: ...poses Refer to your sales order for actual items shipped ADC A12C31 analog clock Mounting bracket with retaining screw CD ROM ADC Set USB Configuration Utility and Operator s Handbook Power cord ADC A...

Page 12: ...Operator s Handbook Rev A P 11 Connect the 50 ohm RG59 coaxial cable not supplied to the BNC connector located on the back panel Insert the AC power cord into the IEC power connector located on the b...

Page 13: ...clock Do not route power or signal cables between the case and the wall along the exterior of the wall which may pinch the power or signal cable and create a hazardous condition A mounting bracket is...

Page 14: ...ADC A12C31 Operator s Handbook Rev A P 13 This page intentionally left blank...

Page 15: ...Status LED The red LED on the ADC A12C31 clock face located at the 6 00 indicates LED STATE STATUS INDICATION Off The clock acquired valid time code and has synchronized its internal RTC to the time...

Page 16: ...the configuration mode to the use of the DIP switches the unit must be reset to factory default As shown on page 22 Time Zone Offsets All time code analog clocks maintain time as UTC A time zone offse...

Page 17: ...ay of October Please carefully consult the section entitled Device Settings for details on setting daylight time To ensure proper hands free year around operation DST adjustments must be configured us...

Page 18: ...ADC A12C31 Operator s Handbook Rev A P 17 This page intentionally left blank...

Page 19: ...itch software configuration offset options set to off in order to display UTC time This is the factory default configuration is defined as SETTING CONFIGURATION SELECTION Disabled Time Zone Offset Dis...

Page 20: ...offset OFF OFF ON OFF 5 hour offset ON OFF ON OFF 6 hour offset OFF ON ON OFF 7 hour offset ON ON ON OFF 8 hour offset OFF OFF OFF ON 9 hour offset ON OFF OFF ON 10 hour offset OFF ON OFF ON 11 hour o...

Page 21: ...8 DST adjustment disabled OFF OFF default US Canada DST enabled ON OFF US standard through Fall 2006 US DST enabled OFF ON new US standard Spring 2007 EU DST enabled ON ON European Union The incoming...

Page 22: ...OFF 70 OFF ON 100 ON ON S2 5 This switch is currently undefined and reserved for future use Function S2 5 Reserved OFF default Reserved ON S2 6 Set the second hand motion mode Function S2 6 Sweep cont...

Page 23: ...hen doing comparisons To adjust the hands 1 Select Set using switch S2 8 ON 2 Select either the 12 00 00 OFF or 6 00 00 ON position using switch S2 7 3 Depress and release either button B1 or B2 to mo...

Page 24: ...switches in the off position This default configuration results in the time displayed as Time Zone Offset Daylight Saving Time Time Code Date Encoding None Disabled Disabled Reset Factory Default Con...

Page 25: ...ed with the time code clock Installation To install the software program on your server workstation PC complete the following steps 1 Insert the CD Time Code Product that shipped with your clock 2 Run...

Page 26: ...e a USB cable not supplied and connect to the PC The Windows Plug and Play manager will detect a new USB device and request device drivers If Windows is unable to install the USB device drivers the sy...

Page 27: ...his display update is not precise but is meant to give you a view of the clock display time for basic troubleshooting and maintenance purposes Also included is a Time Code Status which displays the ty...

Page 28: ...e and click OK to close the window Changes are applied when you click OK Daylight Saving Time Configure and or enable the daylight saving function by clicking the Daylight Saving Time button North Ame...

Page 29: ...ic detection and gain control circuit for the incoming SMPTE 30 25 24 fps longitudinal linear time code or for IRIG B 0 pulse width modulated or IRIG B 1 amplitude modulated time code To support commo...

Page 30: ...be set to the time of the PC or a manual time and date can be entered Practical use of this feature requires the clock to be removed from the time code reference When the clock has access to a valid t...

Page 31: ...to set clock 3 Enter the correct hour minute and second currently displayed on the face of the clock If the second is not currently aligned on a second mark you can nudge the second hand forward incr...

Page 32: ...ADC A12C31 Operator s Handbook Rev A P 31 This page intentionally left blank...

Page 33: ...drop frame IRIG B 1 1kHz amplitude modulated 3 1 modulation ratio IRIG B 0 dc offset level shifted un modulated pulse width modulated TTL level Nominal Level 1 5 Vpp 0dB 600 Level Range 0 175 12 Vpp...

Page 34: ...holdover without applied external power Clock hand alignment settings are maintained in non volatile flash and are not affected by either loss of power or internal battery voltage Operating Storage T...

Page 35: ...es 5 The time code reference to the ADC A12C31 is not a recognized format Verify that your time code reference is providing one of the time code formats that the ADC A12C31 can decode Not displaying t...

Page 36: ...The date shown in the status window of ADC Set configuration utility is always 01 01 2000 Possible reasons solutions 1 Your time code reference is not providing date year information The DST adjustmen...

Page 37: ...If your clock has a stainless steel case a cleaner and polish designed for use on stainless steel is recommended Use a recommended product to maintain and protect the stainless steel finish while resi...

Page 38: ...he lens Don t use abrasive or highly alkaline cleaners Don t use paper towels paper products rayon or polyester cloths to clean or dry the lens Don t scrape the lens with squeegees razor blades or oth...

Page 39: ...tach a tag to the unit with the following information Your company name address and telephone number The name of the contact person at your company The RA number The unit serial number An explanation...

Reviews: