background image

22

PART LIST—Model No. 831.105150

R0400A

Note: “#” indicates a non-illustrated part. Specifications are subject to change without notice.

Key No. Qty.

Description

1

8

Buckle Screw

2

4

Buckle

3

2

Bracket Screw

4

4

Mounting Bolt

5

4

Mounting Nut

6

1

Blue Lens

7

1

Heater Switch

8

4

Small Star Washer

9

1

Heat Sensor

10

2

Filter Cartridge

11

1

Hose Cap

12

1

Not used

13

1

Pump Motor

14

1

Control Unit

15

1

Spa Unit

16

1

Console

17

1

Air Control Knob

18

1

Spa Cover

19

4

Control Unit Screw

20

2

Small Index Nut

21

1

Adjustment Bracket

22

1

Hose Washer

23

2

Small Bracket Screw

24

1

Sensor Fitting

25

6

Multidirectional Jet

26

1

Red Lens

Key No. Qty.

Description

27

1

1/2” O-ring

28

1

Console Wire Harness

29

2

Wing Nut

30

1

Console Bracket

31

2

Cover Screw

32

2

Suction Cover

33

1

Drain Plug

34

6

Rubber Washer

35

1

Rubber Gasket

36

1

1 1/2” Elbow Pipe

37

1

2” O-ring

38

1

Filter Diverter Valve

39

10

#8 x 1 1/2” Screw

40

1

Basket

41

1

Filter Diverter

42

1

Weir Door

43

1

Foam, Weir

44

1

Trim Plate

#

4

Access Cover Screw

#

1

Access Cover

#

2

Key

#

1

Starter Chemical Pack

#

1

Light Bulb

#

1

Userʼs Manual

42

43

44

38

10

40

41

39

EXPLODED DRAWING—Model No. 831.105150

R0400A

Summary of Contents for 831.105150

Page 1: ...The trained technicians on our customer hot line will provide immediate assistance free of charge to you CUSTOMER HOT LINE 1 877 897 7493 Mon Fri 6 a m 6 p m MST Model No 831 105150 Serial No Write th...

Page 2: ...ishandling damage resulting from improper winterization damage to the spa shell resulting from improper chemical treatment damage to the spa shell resulting from exposure to extreme temperatures or da...

Page 3: ...of minutes if exposed to the sun while it is empty These high temperatures can cause significant damage such as blis tering of the shell surface and warping of the spa shell Any damage caused by sun...

Page 4: ...r below Lower temperatures are also recommended for chil dren Children should not be allowed to swim under the surface of the water in the spa 26 WARNING To reduce the risk of injury Always use an acc...

Page 5: ...erminalmarked G GR Ground Grounding or with the symbol is located inside the supply terminal box or compartment To reduce the risk of electric shock this terminal must be connected to the grounding me...

Page 6: ...ughout the body The RENEW 515 gives you the specialized treatment you need to feel your best For your safety and benefit read this manual care fully before using the RENEW 515 If you have addi tional...

Page 7: ...ble with a deck system that is built flush with the top of the spa provided you leave access to the motor for servic ing 8 Make sure to note any other considerations such as aesthetics or privacy conc...

Page 8: ...information on the previous two pages Remove the four cover screws from the access cover Remove the access cover from the Spa Unit 15 by sliding the access cover down and pulling the bottom of the acc...

Page 9: ...rawing Remove the latch from the Buckle 2 Attach the Buckle to the wood panel with two Buckle Screws 1 Note It may be helpful to use a drill with a 1 16 bit to make starter holes in the wood panel It...

Page 10: ...ce where it will be visible to all users of the RENEW 515 Whenever the spa is moved the sign must also be moved and reposted near the spa If the sign becomes lost or illegible call our toll free Custo...

Page 11: ...you refill the spa Once you have verified that the spa is functioning properly and the water has cir culated for a while remove the spa cover and add 1 3 of the Bromine Base bottle and 1 3 of the Non...

Page 12: ...spa is ozone ready An optional ozone generator can be installed to utilize the ozone jet C Ozone provides a way to help sanitize your spa with minimal chemical treatment The suction vents D near the...

Page 13: ...e The thera jets will operate at full speed To turn the pump on low press the button again The thera jets will operate at low speed After you press the button a third time the thera jets will shut off...

Page 14: ...ngth of the cycle press the light and up buttons at the same time The length of the cycle will appear in the temperature display Press the up and down buttons to select the desired cycle length Note T...

Page 15: ...the wood panel exterior twice a year with an additional coat of weather sealant Contact your local spa and pool supplier for advice on which sealants work best in your climate CLEANING THE SPA SHELL...

Page 16: ...d 7 8 If the level is too low add a pH increaser usually soda ash If the level is too high add a pH reducer usually sodium bisulfate Test the water again after five minutes See the instructions with y...

Page 17: ...s Push the handles into the closed position and turn the handles until they lock into place If you are planning to work on the pump or motor you will also need to drain the pump see this page To open...

Page 18: ...e filter door Removing and Cleaning the Filter Cartridges 1 Follow steps 1 through 4 at the left to remove the basket 2 Reach into the housing and locate the plastic diverter on top of the filter cart...

Page 19: ...TENANCE NOTES Maintenance is an important part of keeping your spa in top operating condition Use the space below to make any notes you may want to remember for future reference or to keep a maintenan...

Page 20: ...the spa cover The spa cover must be tight for the water to heat Set the air control to low Set the temperature to the desired setting The water will heat at 2 F 1 C per hour If you are using the spa...

Page 21: ...PA CONTINUES TO RUN AFTER IT HAS BEEN SHUT OFF a To turn the spa jets on high press the Pump button once To turn the spa jets on low press the control twice To turn the spa jets off press the control...

Page 22: ...Screw 20 2 Small Index Nut 21 1 Adjustment Bracket 22 1 Hose Washer 23 2 Small Bracket Screw 24 1 Sensor Fitting 25 6 Multidirectional Jet 26 1 Red Lens Key No Qty Description 27 1 1 2 O ring 28 1 Con...

Page 23: ...1 2 2 6 9 14 15 16 17 18 32 31 29 30 25 26 8 19 19 8 8 7 24 19 4 5 13 11 27 33 37 36 35 25 34 21 3 23 23 20 28 22 EXPLODED DRAWING Model No 831 105150 R0400A 23...

Page 24: ...excluding holidays To help us assist you please be prepared to give the following information when calling The MODEL NUMBER of the product 831 105150 The NAME of the product IMAGE RENEW 515 hydrothera...

Reviews: