ELECTRICAL CONNECTION

The gas cooktop requires a 120 VAC, 60Hz electrica lsupply to operate the 
electronic ignition system. The service should have its own 15 amp circuit 
breaker. A ground fault circuit interrupter (GFCI)is not recommended and 
may cause interruption of operation. 
The cooktop is equipped with a powercord witha 3 prong grounding plug. 
To minimize shock hazard, the power cord must be plugged into a mating 
3 prong grounded outlet, grounded to conform with the National Elec-
trical Code, ANSI/NFPA 70 latest edition ,or Canadian Electrical Code 
(CSA) and all local codes and ordinances. Refer to the illustration below. 
IMPORTANTNOTE:Do not ground to a gas pipe.

GAS CONNECTION

All gas connections must be made according to national and local codes. 
This gas supply (service) line must be the same size or grater than the 
inlet line of the appliance. This range uses a ½”NPT inlet. Sealant on all 
pipe joints must be resistive to LP gas.

1. 

Manual Shut-off Valve: This installer-supplied valve must be installed in the gas service 
line ahead of the appliance in the gas stream and in a position where it can be reached 
quickly in the event of an emergency. The manual shut-off valve shall be installed 
properly in order to be accessible when appliance is installed in defi nitive position. In 
Massachusetts: A ‘T’ handle type manual gas valve must be installed in the gas supply 
line to this appliance. Refer to the illustration.

2. Pressure Regulator 
1.  All heavy duty, commercial type cooking equipment must have a pressure regulator on the incoming service line 

for safe and effi cient operation, since service pressure may fl uctuate with local demand. The pressure regulator is 
supplied separately with the appliance; regulator has two female threads ½” NPT; it shall be installed properly in 
order to be accessible when appliance is installed in defi nitive position.

2.  This range can be used with Natural or LP/Propane gas. It is shipped from the factory adjusted for use with natural 

gas. The orifi ce hoods must be screwed snug when LP/Propane gas is used(see LP/Propane conversion).

3.  The appliance, its individual shut-off valve, and pressure regulator must be disconnected from the gas supply 

piping system during any pressure testing of that system at pressure is in excess of 1/2psig(3.45kPa).

4.  The appliance must be isolated from the gas supply piping system by closing its individual manual shut-off valve 

during any pressure testing of gas supply piping system at test pressures equal to or less than 1/2psig(3.45kPa).

3. Flexible Connections:
1.  If the unit is to be installed with fl exible couplings and/or quick disconnect fi ttings, the installer must use an heavy 

duty, AGA design-certifi ed commercial fl exible connector of at least ½”(1.3cm)ID NPT(with suitable strain relieves) 
in compliance with ANSI Z21.41 and Z21.69 standards.

2.  In Massachusetts: The unit must be installed with a 36” (3-foot) long fl exible gas connector.
3.  In Canada: CAN 1-6.10-88 metal connectors for gas appliances and CAN 1-6.9M79 quick disconnect device for 

use with gas fuel.

CAUTION: Leak testing of the appliance shall be conducted according to the manufacturer’s instructions. Before placing the 
gas cooktop into operation, always check for leaks with a soapy water solution of other acceptable method. DO NOT USE AN 
OPEN FLAME TO CHECK FOR LEAKS!

Summary of Contents for UHF40

Page 1: ...04 2014 User Instructions Installation maintenance for C O O K T O P S C O O K T O P S cod I 301 xx ...

Page 2: ...cturer will not be responsible for any damage to property or to persons caused by incorrect installation or improper use of the appliance The manufactured reserves the right to make changes to its products when considered necessary and useful without affecting the essential safety and operating characteristics This appliance has been designed for non professional domestic use only This appliance m...

Page 3: ...mponents may be hot enough to cause burns Never leave this appliance unattended when in use Boilovers and greasy spills may smoke or ignite Do not heat unopened food containers such as baby food jars and cans Pressure build up may cause the container to burst and cause injury Before performing service shut off gas supply by closing the gas shut off valve and shut off elec tricity to this appliance...

Page 4: ...kPa The appliance must be isolated from the gas supply piping system by closing its individual manual shutoff valve during any pressure testing of the gas supply piping system at test pressure equal to or less than psi 3 5kPa For use with a pressure regulator The regulator supplied must be used with this appliance it shall be properly installed in order to be accessible when appliance is installed...

Page 5: ...ne for safe and efficient operation since service pressure may fluctuate with local demand The pressure regulator is supplied separately with the appliance regulator has two female threads NPT it shall be installed properly in order to be accessible when appliance is installed in definitive position 2 This range can be used with Natural or LP Propane gas It is shipped from the factory adjusted for...

Page 6: ...lified licensed plumber or gas service company Please provide the service person with this manual before work is started on the range Gas conversions are the responsibility of the dealer or end user WARNING This conversion kit shall be installed by a qualified service agency in accordance with the manufacturer s instructions and all applicable codes and requirements of the authorityhaving jurisdic...

Page 7: ...ifice must be fully screwed in To convert the regulator Fig 1 and Fig 2 for use with the other gas different from which one it is pre arranged it is enough perform the following operations 1 Unscrew by hand the upper metal stopper of the regulator 2 Unscrew by hand the white plastic piece screwed under the above mentioned metal stopper afterward screw it again in opposite way under the metal stopp...

Page 8: ...TURAL A 10500 145 3600 Open Adj TC NATURAL A 15500 180 5600 Open Adj Dual NATURAL A 15500 165 68 8000 15 external Open inner ring Adj Dual aux only NATURAL A 2300 68 1100 Open Adj Griddle NATURAL A 10500 145 3600 Open Adj SR LP E 7000 78 2100 Open 45 R LP E 10500 95 3200 Open 55 Fish Kettle LP E 10500 95 3600 Open 60 TC LP E 15500 117 5600 Open 75 Griddle LP E 10500 95 3600 Open 60 Dual LP E 15500...

Page 9: ...e R forward B Flame with lack of air it is irregular with yellow streaks Move sleeve R backward C Normal flame its colour is light blue Figure 3 Figure 4 Figure 6 DUAL Figure 5 ADJUSTING THE MINIMUM GAS FLOW When installing the gas cooktop you must check that the minimum gas flow of the burners is correctly regulated If the type of gas is changed it is indispensable to adjust the minimum flow The ...

Page 10: ...must not be used for heating purposes IMPORTANT correct positioning of the brass flame distributor d Fig 7 is very important For this purpose ensure that the flame distributor tooth e Fig 7 coincides with the notch b Fig 7 on the aluminium base a Fig 7 To keep the flame distributor covers c new you are advised to remove them before lighting the flame Figure 7 ...

Page 11: ...w to reignite the burner turn the knob in a clockwise direction past the limit stop until you reach the required level SURFACE BURNERS Before lighting place the burner head and cap on each burner base and position the burner grates To check ope ration of the surface burners push in and turn each control knob to the HIGH position The flame should light within 10 seconds If the burners do not light ...

Page 12: ...al cooking is available as an optional accessory Some models are supplied with the spatula shown in Figure 9 which is useful both for cooking and for cleaning the plate CLEANING AND CARING FOR THE FRY TOP It is recommended to clean the plate accurately at the end of each cooking session With the plate hot and the flame at minimum remove the cooking residue using the scraper provided Pour a little ...

Page 13: ...epending on the quantity and temperature of the food the type of gas and of course your own personal taste COOKING TABLE purely indicative values after 10 preheating with the burner at maximum power Knob position fig 13 Type of cooking B sliced aubergines 3 16 thick from 3 to 5 min B sliced potatoes from 5 to 7 minutes B sliced courgettes from 4 to 6 minutes A fish gilthead of about 0 44 lb in 10 ...

Page 14: ... illustration below Reinsert the cooktop into the countertop opening Lift the entire cooktop to make adjustments Attach the brackets to the bottom of the unit Insert the clamping screws into the brackets Use a screw driver to tighten the clamping screws against the underside of the countertop Refer to the illustration below Do not overtighten screws IMPORTANT NOTE Do not seal the cooktop to the co...

Page 15: ...h natural and LP gas If a flexible metal connector is used be sure the tubing is not kinked Open the shut off valve in the gas supply line Wait a few minutes for the gas to move through the line GAS LEAK TESTING Use a brush and liquid detergent to test all gas connections for leaks Bubbles around connections will indicate a leak If a leak appears shut off the gas supply and adjust connections Then...

Page 16: ... to combustible vertical surfaces above 36 91 4 cm the maximum wall cabinet depth must be 13 33 0 cm and wall cabinets within this 8 20 3 cm side clearance must be 18 45 7 cm above the 36 91 4 cm high countertop Wall cabinet above the cooktop must be a minimum of 36 91 4 cm above the countertop This minimum height requirement does not apply if a rangehood is installed over the cooking surface Mini...

Page 17: ...17 ...

Page 18: ...HP765 UH965 UHP1265 A hole of 1 31 32 5 cm x 5 cm must be done on the top for power cable and gas conduit as shown in picture The supplied feet h 0 5 16 0 8 cm must be fitted in the special holes under the hob as shown in picture ...

Page 19: ...e 13 33 0 cm and wall cabinets within this 8 20 3 cm side clearance must be 18 45 7 cm above the 36 91 4 cm high countertop Within the 16 40 64 cm side clearance to combustible vertical surfaces above 36 91 4 cm for UHP665 and UHP765 models the maximum wall cabinet depth must be 13 33 0 cm and wall cabinets within this 8 20 3 cm side clearance must be 18 45 7 cm above the 36 91 4 cm high counterto...

Page 20: ...20 ...

Page 21: ...21 ...

Page 22: ...UHP65 C CN D DN UHP75 C CN D DN UHP95 PC PCN PD PDN FC FCN FD FDN C CN D DN UHP1230 D DN UHP125 PC PCN PD PDN FC FCN FD FDN UHF40 UHF40N UHF40 F FN D DN UHP665 UHP665D UHP965 UHP965 F FD PD 6 6D UHP1265 7 TD F FD UHP765 UHP765D ...

Page 23: ...23 UXLP90F UXLP90FD LEGEND M Terminal board MA Electrical ignition microswitch EL Valve DS1 Electronic controller 00 Black 22 Red 33 White 45 Green 66 Blue K1 Earth wire terminal board N Neutral L Phase ...

Page 24: ...24 ...

Page 25: ...25 NOTES ...

Page 26: ...26 NOTES ...

Page 27: ...27 NOTES ...

Page 28: ...MESTICI S p A Via Antoniana 100 35011 Campodarsego PD Italy Tel 39 049 9200990 Fax 39 049 9201010 mail ilve com www ilve com CANADA A G I SERVICE Phone 450 963 1303 1 888 651 2534 Fax 450 963 8985 email info aginternational ca EuroChef USA 866 844 6566 631 243 0111 ...

Reviews: