15
GAS SUPPLY CONNECTION
Assemble the fl exible metal connector from the gas supply pipe to the gas pressure regulator. You will need to
determine the fi ttings required, depending on the size of your gas supply line, fl exible metal connector and shut-off
valve. Refer to the illustration below. Use a pipe joint compound made for use with natural and LP gas. If a fl exible
metal connector is used, be sure the tubing is not kinked.
Open the shut-off valve in the gas supply line. Wait a few minutes for the gas to move through the line.
GAS LEAK TESTING
Use a brush and liquid detergent to test all gas connections for leaks. Bubbles around connections will indicate a
leak. If a leak appears, shut off the gas supply and adjust connections. Then check connections again. Clean the
detergent solution from the cooktop.
WARNING
Never test for a gas leak with a match or other fl ame
Summary of Contents for UHF40