INSTALLER
17
INSTALLATION
BY A QUALIFIED INSTALLER
Electrical connection
Connecting cable to hob
• Installation of the induction hob should be performed by specialized personnel
and carried out in compliance with current regulations. Make sure that the parts
in tension underneath the hob are protected. The outline for the electrical con-
nection is indicated on the label near the terminal board. In case of direct con-
nection to the network it will be necessary to interpose an omnipolar switch with a
minimum opening between the contacts of 3 mm. Connection to the electrical
network must be separated by the appropriate interruption: switch, fuse.
• Always connect the earthing cable.
• Comply with the connection instructions.
• The terminal board is located under the hob at the back.
• Use a screwdriver to open the cover of the terminal board.
• The yellow-green earth conductor must never be interrupted even by the switch.
The power supply cable must be positioned so that it does not come into contact
with surfaces that have a temperature higher than 50 ° C above the environment.
If it is necessary to replace the power supply cable, contact the assistance service
With respect to the various types of connection, you should utilize the appropriate jum-
pers placed inside the jumper board.
KVI364
SINGLE-PHASE:
Connect the supplied jumper between terminals 1-2 and between
4-5. The phase wire should be connected to terminal 1 or 2. The neutral wire should
be connected to terminal 4 or 5.
TWO-PHASE + N:
Connect the supplied jumper between terminals 4-5. The neutral
wire should be connected to terminal 4 or 5, one phase to terminal 1 and the other
phase to terminal 2.
EARTHING:
The earthing wire should be connected to the dedicated terminal .
KVI394
THREE-PHASE + N:
Connect the supplied jumper to terminals 4-5. The neutral wire
should be connected to terminal 4 or 5; the three phases should be connected to
terminals 1, 2, 3.
EARTHING:
The earthing wire should be connected to the dedicated terminal.