16
INSTALLATION
BY A QUALIFIED INSTALLER
Instructions for installation
The dimensions of the recessed compartment are 565 mm (width) x 485 mm (depth) for
model KHVI364, and 865 mm x 485 mm for model KHVI395. The gasket supplied with
the hob is sufficient to cover the perimeter of the recessed compartment. Its adhesive
withstands a temperature of 100 °C. The induction hob belongs to Class Y. For ideal in-
stallation of the hob, it is recommended to leave the adjacent parts free. However, only
one side wall and one rear wall may be present. Walls should be kept at a minimum
distance of 50 mm. The flush-mounted induction hob, if subject to possible water infil-
tration, should be protected especially at the edge of the recessed compartment with
the strips of putty supplied. Make sure there is a gap of 20 mm for model KHVI364 and
30 mm for model KHVI395 under the bottom of the hob to ensure regular ventilation.
Make sure that there is a gap of at least 5 mm for model KHVI364 and 7 mm for model
KHVI395 between the work surface and the top edge of any drawer or oven to ensure
air escape. Do not introduce any flammable objects inside the drawer located under
the induction hob. The distance between the hob and the extractor hood must comply
with the specifications provided by the hood manufacturer. If such instructions are not
available, observe the minimum distance of 760 mm. The connecting cable must not
be subjected to tensile stress after installation. Installation of the induction hob on mobile
environments (e.g., boats) should be performed by trained personnel.
MIN. 50 mm
M
IN
. 20 mm
M
IN
. 5 mm
MIN. 50 mm
*
MIN. 70 mm
M
IN
. 20 mm
*
M
IN
. 30 mm
M
IN
. 5 mm
*
M
IN
. 7 mm
*
M
IN
. 7 mm
*
M
IN
. 30 mm
*
solo per modello KHV395