28
The appliances are prepared for connection to the voltage shown on the data
plate.
Before connecting the appliance to the mains check that:
• the electromagnetic switch or the socket are able to support the applian-
ce’s load (see data plate);
• the power supply system must have an efficient earth.
The appliance is supplied with a cable but without a plug: the connection must
be made taking into account that the green-yellow cable is the earth conductor
and it must never be interrupted.
For direct connection to the mains, it is necessary that:
• the relief valve and domestic system can support the equipment’s load (see
data plate)
• the power supply system must have an efficient earth
• the socket or omnipolar switch, with a minimum 3 mm contact opening, must
be easily reached once the appliance has been installed a mains shut-off
must be incorporated in accordance with installation rules.
The green-yellow earth cable must never be interrupted even by the switch. The
power cable must be routed in such a way that it does not come into contact
with surfaces that have a temperature greater than 50°C above room tempera-
ture. If cable replacement is necessary contact the after-sales service.
*
HP965B, HP1265B, HP90B, HP120B
INSTALLATION
Electric connection
Power
(230V)
(240V)
Hotplate (Ø 115)
550 W
600 W
Hotplate (Ø 115)
920W
1000 W
Hotplate (Ø 115)
1380 W
1500 W
Barbeque
1900 W
2070 W
Barbeque*
2650 W
2880 W