ERROR CODE
ERROR DESCRIPTION
GUIDE
E03 +
Continuous
sound, or
O Er03
Continuous activation of the sensors
for more than 10 seconds, caused by
the presence of objects or liquids on
the glass in the control area.
Remove objects and/or l clean the glass.
If the problem persists get in touch with the authorized
service center quoting the error code.
E21
The control switches off due to
overtemperature to prevent damage
to the electronics.
Get in touch with the authorized service
center quoting the error code.
tecnica
E22 o Er22
Error of the command sensors.
The command switches off after 3.5-
7.5 seconds. In one or more sensors
the detection threshold is incorrect.
Get in touch with the authorized service
center quoting the error code.
tecnica
E20 o Er20
Microcontroller memory anomaly.
Get in touch with the authorized service
center quoting the error code.
tecnica
E36 o Er36
Short circuit in the command
temperature sensor.
Get in touch with the authorized service
center quoting the error code.
tecnica
E31 o Er31
Anomaly in the configuration of the
cooking zones.
Get in touch with the authorized service
center quoting the error code.
tecnica
E47 o Er47
Abnormal communication between
the control and one or more cooking
zones.
Get in touch with the authorized service center
quoting the error code.