background image

Installation

 

 

Ilumipod Inground IP Series User Manual (Rev. 02) 

 

 

Make sure to 
connect the 
Ilumipod Inground 

IP product to a power line 
with the proper voltage 
and frequency, as per the 
specifications in this 
manual or on the 
product’s sticker. 
 
 
 
 

The listed 
current rating 
indicates the 
maximum 

current draw during 
normal operation. 
 
 
 

Always connect 
the Ilumipod 
Inground IP 

products to protected 
circuits (CB or fuse) with 
an appropriate electrical 
ground to avoid the risk of 
electrocution or fire. 

 
 
 
 

Never connect an 
Ilumipod Inground 
IP product to a 

rheostat (variable resistor) 
or dimmer circuit, even if 
the rheostat or dimmer 
channel serves only as a 
0 to 100% switch. 
 

 
 
 
 
 
 
 
 
 
 

Make sure to use 
power and signal 
cables with the 

indicated outer diameters 
to ensure that the 
corresponding gland nut 
makes full contact with 
the cable’s external 
insulation. This is required 
to keep the product’s IP67 
rating when fully adjusted. 
 
 

AC Power 

Input Voltage and Frequency 

The products in the Ilumipod Inground IP Series have an auto-ranging power supply with an 
input voltage range of 100~240 VAC, 50/60 Hz. 

Power Consumption 

To determine the power requirements for any of the Ilumipod Inground IP products see the 
label affixed to the side of the product. Alternatively, you may refer to the corresponding 
specifications chart in the 

Technical Information

 chapter of this manual.  

Junction Box Wiring 

The Ilumipod Inground IP products have an IP67 rated junction box where the power and signal 
cables come into the unit. The cables access the junction box through individual (signal and 
power) IP67 rated stainless steel gland nuts. 

Make sure that the junction seal is clean before placing the cover back on. In addition, tighten 
the gland nuts and the junction cover to prevent water from entering the junction box and 
causing a short. 

The figure below shows the connections in the junction box. 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Power Wiring 

To provide AC power for any of the Ilumipod Inground 
IP products, you must run a single SJTW rated 3-
conductor cable (AWG18/3, 6~8 mm external diameter) 
from the power distribution box into the installation 
sleeve and the product’s junction box. 

Strip the end of the AC power cable that will connect to 
the junction box as indicated in the figure on the right. 

 

 

Connection 

Wire (US) 

Wire (Europe) 

Live Black 

Brown 

Neutral White  Blue 

Ground Green/Yellow Green/Yellow 

AC Power Input Wiring 

  

 

 

Summary of Contents for Ilumipod Inground IP Series

Page 1: ...I Il lu um mi ip po od d I In ng gr ro ou un nd d I IP P S Se er ri ie es s User Manual...

Page 2: ...en consent Document Printing For better results print this document in color on letter size paper 8 5 x 11 inches double sided If using A4 paper 210 x 297 mm configure your printer to scale the conten...

Page 3: ...5 Installation Sleeve Orientation 5 Installation Sleeve Setup 5 Beam Angle Adjustment 6 AC Power 7 Input Voltage and Frequency 7 Power Consumption 7 Junction Box Wiring 7 Power Wiring 7 Signal Wiring...

Page 4: ...lumipod Inground 36 IP 15 VW 20 Ilumipod Inground 36 IP 30 VW 21 Ilumipod Inground 36 IP 15 RGB 22 Ilumipod Inground 36 IP 30 RGB 23 Ilumipod Inground Tri 12 IP 16 24 LED Disclaimer 25 LED Life 25 LED...

Page 5: ...GB 36 IP VW or Tri 12 IP Warranty Card Quick Reference Guide Unpacking Instructions Immediately upon receiving a product from ILUMINARC carefully unpack the carton Check the contents of the box to ens...

Page 6: ...ect eye exposure to the light source while the product is on Always disconnect the Ilumipod Inground IP product from its power source before servicing Always connect the Ilumipod Inground IP product t...

Page 7: ...ompatible ILUMICON compatible Ilumipod Inground 36 IP VW Features Operating modes 1 channel Dimmer 2 channel Warm white cool white 3 channel Warm white cool white dimmer High power 1 W 750 mA Warm Whi...

Page 8: ...Product Description 4 Ilumipod Inground IP Series User Manual Rev 02 Product Dimensions All Ilumipod Inground IP Series models...

Page 9: ...er units because it may compromise the IP rating of the junction box Instead use individual cables from the product to the corresponding distribution boxes Installation Sleeve Orientation Orient the i...

Page 10: ...g untouched any two adjacent nuts 4 Wait a few seconds for the seal to expand which lowers the possibility of damaging the seal 5 Complete the removal of the two remaining nuts 6 Remove the stainless...

Page 11: ...z Power Consumption To determine the power requirements for any of the Ilumipod Inground IP products see the label affixed to the side of the product Alternatively you may refer to the corresponding s...

Page 12: ...you must run a single IP67 rated DMX signal cable shielded 2 conductor AWG24 2 6 5 mm external diameter from the signal distribution box into the installation sleeve and the product s junction box Ext...

Page 13: ...tions to operate these products with each of the above controllers are in the Operation chapter of this manual DMX Controller The Ilumipod Inground IP products can work with a standard DMX controller...

Page 14: ...ILUMINARC suggests that you connect no more than 20 products in this mode and keep the total distance to less than 60 m 197 ft Otherwise you might need to use an optically isolated signal amplifier I...

Page 15: ...mipod Inground IP Series have distinct menu maps based on the colors they produce whether RGB or White The Ilumicode controller presents the functions for both types of products White Functions Menu M...

Page 16: ...f them that do not correspond with this menu map Skip them as they do not work with the RGB only output products If you scroll after STRB you will see the AMBE COOL and WARM colors Just skip them as t...

Page 17: ...backwards respectively within the Menu Map options Press ENTER to accept the selected value for an option This will send that value to the product s DMX Personality All Ilumipod Inground IP products...

Page 18: ...OL or WARM 3 Select a color value 000 255 Color Calibration Only for 36 IP RGB and Tri 12 IP 1 Go to CALIB 2 Select a white color WHITE 1 11 or RGBTOW 3 Select an RGB color RED GREN or BLUE 4 Select a...

Page 19: ...170 171 200 201 205 206 210 211 215 216 220 221 225 226 230 231 235 236 240 241 245 246 250 251 255 No Function Red 100 Green Up Blue 0 Red Down Green 100 Blue 0 Red 0 Green 100 Blue Up Red 0 Green D...

Page 20: ...0 255 0 100 4 Module 2 Red 000 255 0 100 5 Module 2 Green 000 255 0 100 6 Module 2 Blue 000 255 0 100 VW Channel Function Value Percent Setting 1 Warm White 000 255 0 100 2 Cool White 000 255 0 100 VW...

Page 21: ...making sure that you are not pulling the signal or AC power cables 5 Use a wet vacuum cleaner to remove any liquid inside the installation sleeve and around the product s housing 6 Inspect the cables...

Page 22: ...up when using DMX Wrong personality Change the personality Wrong DMX address Change the DMX address Circuit breaker fuse keeps tripping blowing Excessive circuit load Check total load on electrical ci...

Page 23: ...User Manual Rev 02 19 Exploded View Reference Description 1 Stainless steel cover 2 15 mm tempered glass 3 Diaphragm 4 LED lens panels 5 LED boards 6 Heat sink 7 Power supply 8 Control board 9 Inner...

Page 24: ...ut 1 lamp s rated Lumens lamp 1380 Max Candela 8 753 5 at Horizontal 180 Vertical 3 Input Wattage 43 1 Luminous Opening Point Test 2009 ALL Test Lab Iluminarc R D Optics Laboratory Photometry Type B C...

Page 25: ...lamp s rated Lumens lamp 3000 Max Candela 3 534 3 at Horizontal 0 Vertical 0 Input Wattage 46 5 Luminous Opening Point Test 2009 ALL Test Lab Iluminarc R D Optics Laboratory Photometry Type B CIE Clas...

Page 26: ...amp s rated Lumens lamp 1380 Max Candela 8 753 5 at Horizontal 180 Vertical 3 Input Wattage 43 1 Luminous Opening Point Test 2009 ALL Test Lab Iluminarc R D Optics Laboratory Photometry Type B CIE Cla...

Page 27: ...lamp s rated Lumens lamp 1380 Max Candela 2 520 5 at Horizontal 0 Vertical 3 Input Wattage 43 3 Luminous Opening Point Test 2009 ALL Test Lab Iluminarc R D Optics Laboratory Photometry Type B CIE Clas...

Page 28: ...p s rated Lumens lamp 1380 Max Candela 5 633 6 at Horizontal 0 Vertical 0 Input Wattage 17 6 Luminous Opening Point Test 2009 ALL Test Lab Iluminarc R D Optics Laboratory Photometry Type B CIE Class D...

Page 29: ...limitations and inconsistencies related to CRI Results may vary depending on the environmental factors involved For this reason the US Department of Energy DOE states that CRI should be considered as...

Page 30: ...Your name Your address Your phone number The RMA A brief description of the problem Be sure to pack the product properly Any shipping damage resulting from inadequate packaging will be the customer s...

Page 31: ...te Construction Housing Cast aluminum body and stainless steel outer ring Color Black body and silver outer ring Lens cover Impact resistant drive over rated Ingress protection IP rating IP67 Photomet...

Page 32: ...ousing Cast aluminum body and stainless steel outer ring Color Black body and silver outer ring Lens cover Impact resistant drive over rated Ingress protection IP rating IP67 Photometrics Installed op...

Page 33: ...LEDs Construction Housing Cast aluminum body and stainless steel outer ring Color Black body and silver outer ring Lens cover Impact resistant drive over rated Ingress protection IP rating IP67 Photo...

Page 34: ...ILUMINARC 5200 NW 108 th Avenue Sunrise FL 33351 U S A Tel 954 929 1115 FAX 954 929 5560 www iluminarc com Ilumipod Inground IP Series User Manual Rev 02 August 2011...

Reviews: