Operation

Configuration (Static Mode)

To set the Ilumiline SL to operate in a static or strobing color without DMX:

1. Go to the 

STATIC 

main level.

2. Select the parameter to configure, from

RED

,

GREEN

,

BLUE

,

COOL

 (lime),

SOLID

 (no function), or

STROBE

3. Set the selected parameter to the desired level, from 

000–255

.

4. Repeat until the static mode is set as desired.

Configuration (Settings)

Dimmer Speed

To set the dimmer speed:

1. Go to the 

DIMMER 

main level.

2. Select the dimmer speed from 

OFF

 (linear dimmer), 

DIM1

 (fastest), 

DIM2

DIM3

or 

DIM4

 (slowest).

Color Calibration

There are 4 color calibration options for the Ilumiline SL: 

OFF

 (maximum output/unbalanced white), 

RGBTOW

 (quad-color calibration), 

UC

 (“universal”, tri-color calibration to match legacy products), and the 

color macro 

WHITE 1–11

 settings.

To select the color calibration mode:

1. Go to the 

SETTINGS

 main level.

2. Select the 

COLOR

 option.

3. Select the calibration mode, from 

OFF

RGBTOW

, or 

UC

.

Color Macro White Balance

To adjust the color macro white balances:

1. Go to the 

CALIB

 main level.

2. Select the macro to adjust, from 

WHITE 1–11

.

3. Select the color level to adjust, from 

RED

GREEN

BLUE

, or 

COOL

 (lime).

4. Set the level of the selected color, from 

000–255

.

5. Repeat until the white balances are set as desired.

RGBTOW Mode

To adjust the color calibration in 

RGBTOW

 mode:

1. Go to the 

CALIB

 main level.

2. Select the 

RGBTOW

 option.

3. Select the color level to adjust, from 

RED

GREEN

BLUE

, or 

COOL

 (lime).

4. Set the level of the selected color, from 

000–255

.

5. Repeat until the calibration is set as desired.

Universal Calibration

To adjust the color calibration in 

UC

 mode:

1. Go to the 

UC-CALIB

 main level.

2. Select the color level to adjust, from 

RED

GREEN

, or 

BLUE

.

3. Set the level of the selected color, from 

000–255

.

4. Repeat until the calibration is set as desired.

Factory Reset

To reset the product to factory default settings:

1. Go to the 

SETTINGS

 main level.

2. Select the 

RESET

 option.

3. Select from 

NO

 (cancel) or 

YES

 (reset).

Summary of Contents for Ilumiline SL

Page 1: ...User Manual Model ID ILUMILINESL...

Page 2: ...purpose without written consent from Chauvet Document Printing For best results print this document in color on letter size paper 8 5 x 11 in double sided If using A4 paper 210 x 297 mm configure the...

Page 3: ...king 5 DMX Linking 6 Remote Device Management RDM 6 Beam Shaping Filters 6 Mounting 7 Orientation 7 Rigging 7 Procedure 7 4 Operation 8 Ilumicode RDM2go Control 8 Menu Map 8 Configuration DMX 9 Contro...

Page 4: ...se harmful interference and 2 This device must accept any interference received including interference that may cause undesired operation Any changes or modifications not expressly approved by the par...

Page 5: ...er and Wiring Make sure the power cord is not crimped or damaged Always make sure you are connecting this product to the proper voltage in accordance with the specifications in this manual or on the p...

Page 6: ...t for fitting into available space while interchangeable easy to install beam spread filters to help the fixture adapt to various applications and throw distances Additionally the lime emitter allows...

Page 7: ...Ilumiline SL User Manual Rev 1 Introduction Product Dimensions 0 81 in 20 5 mm 2 59 in 65 9 mm 12 in 305 mm 1 18 in 30 mm 1 91 in 48 6 mm 2 68 in 68 2 mm 3 42 in 87 mm 3 04 in 77 1 mm 0 33 in 8 5 mm 0...

Page 8: ...ou can power link up to 46 products at 100 V up to 52 products at 120 V up to 75 products at 208 V up to 88 products at 230 V up to 88 products at 240 V or up to 92 products at 277 V Proprietary 2 in...

Page 9: ...anagement or RDM is a standard for allowing DMX enabled devices to communicate bi directionally along existing DMX cabling Check the DMX controller s User Manual or with the manufacturer as not all DM...

Page 10: ...oses Make sure that the structure onto which you are mounting the product can support the product s weight See the Technical Specifications for weight information When mounting the product overhead al...

Page 11: ...ear mode from fastest DIM1 to slowest DIM4 CALIB WHITE 1 11 RED 000 255 Determines the white balance for the color macros GREEN RGBTOW BLUE Determines the white balance when RGBTOW is active COOL PERS...

Page 12: ...annel Assignments and Values ARC1 3 Channels ARC1 D 4 Channels ARC2 4 Channels See the Starting Address section for the highest starting address you can select for each personality Make sure that the...

Page 13: ...000 255 0 100 5 Preset color 000 010 No function 011 020 Light Salmon 021 025 Scarlet 026 030 Flame Red 031 045 Dark Salmon 046 050 Sunset Red 051 060 CID To Tungsten 061 065 Soft Golden Amber 066 070...

Page 14: ...5 5000K 116 129 5001 5599K 130 5600K 131 144 5601 5999K 145 6000K 146 159 6001 6499K 160 6500K 161 174 6501 6999K 175 7000K 176 189 7001 7999K 190 8000K 191 204 8001 9999K 205 255 10000K 7 Strobe 000...

Page 15: ...21 025 Scarlet 026 030 Flame Red 031 045 Dark Salmon 046 050 Sunset Red 051 060 CID To Tungsten 061 065 Soft Golden Amber 066 070 Urban Sodium 071 080 LEE Yellow 081 085 Ice And A Slice 086 110 Dark Y...

Page 16: ...4500K 101 114 4501 4999K 115 5000K 116 129 5001 5599K 130 5600K 131 144 5601 5999K 145 6000K 146 159 6001 6499K 160 6500K 161 174 6501 6999K 175 7000K 176 189 7001 7999K 190 8000K 191 204 8001 9999K 2...

Page 17: ...Select the COLOR option 3 Select the calibration mode from OFF RGBTOW or UC Color Macro White Balance To adjust the color macro white balances 1 Go to the CALIB main level 2 Select the macro to adjus...

Page 18: ...uency To clean the product follow the instructions below 1 Unplug the product from power 2 Wait until the product is at room temperature 3 Use a vacuum or dry compressed air and a soft brush to remove...

Page 19: ...tary 2 in 1 Proprietary 2 in 1 Power Connection Recommended Cable Total Max Cable Length Connector Max Diameter 3 7 ft 1 13 m hardwire to proprietary waterproof cable Power and data interface 14 AWG 2...

Page 20: ...uest Clearly label the package with an RMA number Iluminarc will refuse any product returned without an RMA number Before sending the product clearly write the following information on a piece of pape...

Page 21: ...uvetlighting eu Brookhill Road Industrial Estate Pinxton Nottingham UK Website www iluminarc com NG16 6NT Voice 44 0 1773 511115 Fax 44 0 1773 511110 Benelux Address Stokstraat 18 Email BNLtech chauve...

Reviews: