© Copyright 2020, ILUMINAR Lighting
Subject to change without notice.
7
6
Photo A
Photo B
Photo C
ROLL LOCK
SOCKET
INSTALLATION
1. Slide both levers away from the lamp to the “Open” position.
(Photo A) Each socket applies up to 5mm of lateral pressure to
ensure a secure fit.
2. Ensure both wire ends/leads are straight - DO NOT BEND
THE WIRE LEADS! Ensure the wire leads are NOT FRAYED OR
LOOSE (if there are frays, twist them back into the wire leads).
Small frays of metal can cause the fixture to arc or melt.
The oils from your hands can be dangerous when burning off in
the high heat of the lamp.
CAUTION: DO NOT HANDLE THE LAMP WITH BARE HANDS
Quartz Outer Jacket
Arc Tube
Wire Lead
PROPRIETARY ROLL LOCK SOCKET (ILUMINAR FIXTURES)
ILUMINAR Lighting created the first of its kind, single-handed “Roll-Lock” socket for simple, one-
handed lamp installation. We know it can get tricky to load new lamps - it’s too easy to drop the
lamp and lose that investment. Keep your lamps safe when you install using the Roll Lock socket. The
Roll Lock Socket works with all DE Lamps - HPS, MH, and CMH, for all wattage options.
1-877-540-5588
iluminarlighting.com
3. Using soft gloves to handle the lamp, slide the lamp into the
fixture (with metal leads straight) until the lamp is fully seated.
4. Rotate the bulb, itself, to lock it into place (so that it will not move).
5. Slide both socket levers toward the lamp to the “closed” position to
add a second lock to fix the lamp into position. If the lamp is seated
correctly, both levers should easily slide inward to lock the DE lamp
into the socket. It is now ready to use.
DO NOT
force the levers closed, this can cause damage to both the
lamp and the levers. DO NOT handle the lamp with bare hands. Always
wear surgical or cloth gloves when handling the lamp to minimize
fingerprints and oils left on the lamp. If the lamp needs cleaning after
installation, use a soft, dry cotton cloth to wipe off fingerprints/skin
oils.
1. To remove or change the lamp, simply follow the steps above.
2. Slide both socket levers away from the lamp to the “Open” position.
(Photo A)
3.
USING SURGICAL OR COTTON GLOVES
, gently rotate the lamp
itself to open the Roll Lock Socket.
4. Gently lift the lamp out of the sockets.
5. Rotate the new bulb into place.
6. Slide both socket levers toward the lamp to the “closed” position.
ROLL LOCK
SOCKET
UNINSTALL
WATCH ROLL LOCK
VIDEO GUIDE
ROLL LOCK
SOCKET
INSTALLATION
(CONT.)
DO NOT FRAY
DO NOT BEND