SECTION 4  Safety 

 

CAUTION!

  

 

 

1.  Read the complete Operation Manual before operating. Failure to follow instructions 

may result in damage to the ionizer and/or personal injury. 

 
2.  This unit is supplied with a 3-prong grounding plug, which must be inserted in an 

appropriate, properly wired, and grounded receptacle. The 24VDC AC adapter used 
with the unit provides a ground connection at its output. Do not defeat the electrical 
ground, grounding and proper wiring are required for proper operation. 

 
3.  Do not ground or make electrical connections of any kind to the unit’s metal fan 

guards located on the intake and output. 
 

4.  A factory-qualified service technician must perform component service and repairs. 

Please contact SIMCO Customer Service for information. 

 

WARNING!

  

 

 
5.  Keep the unit dry. Do not operate the unit in flammable, volatile or explosive atmosphere. 
 
6.  Do not insert objects through the unit’s intake or outlet grilles. Damage to the ionizer 

and/or personal injury may result. 

 

 
SECTION 5  Installation

 

 
5.1   Unpacking 
Carefully remove the equipment from the carton and inspect contents. Note that the unit 
has been bagged and vacuum sealed in a Class 100 cleanroom. To prevent 
contamination and eliminate the need for additional wipe downs, the unit should be un-
bagged in a cleanroom environment.   
 
5.2   Installing  
The Centurion single fan ionizer is designed for portable or permanent operation. 
Typically, the unit should be positioned such that there is good airflow provided to the 
critical area. Generally this requires that the unit be within 36” inches of the intended 
target. The stand provided with the unit can be used in a permanent operation by bolting 
it to a sturdy flat surface such as a wall or shelf. The unit can be mounted horizontally if 
required. The stand may be removed if required.  

 

Summary of Contents for SIMCO CENTURION

Page 1: ...single fan DC ionizer offers superior balance performance with its novel emitter array design and high gain dual feedback circuitry The Centurion eliminates static charges cleanly quickly and reliably...

Page 2: ...made to the output of the emitter array are seen promptly as ion output changes in the air The resulting balanced stream of ionized air is delivered to the work area to provide static neutralization...

Page 3: ...an Speed Adjusted using a potentiometer adjustment tool Adjustment located on the rear panel of the unit Offset Balance Adjustable to zero using a potentiometer adjustment tool Adjustment access is lo...

Page 4: ...e unit in flammable volatile or explosive atmosphere 6 Do not insert objects through the unit s intake or outlet grilles Damage to the ionizer and or personal injury may result SECTION 5 Installation...

Page 5: ...ize static is dependent on the fan speed setting For fastest charge neutralizing performance the unit should be adjusted for the highest fan speed The Ion Balance adjustment located on the rear of the...

Page 6: ...removal from its pivot pins The emitters are installed in sockets for easy insertion and removal Using a long nose pliers pull the emitters out along the radial direction gripping the shaft only takin...

Page 7: ...n no event shall SIMCO be liable for incidental or consequential damages except where state laws override This warranty extends to the original purchaser and is not transferable No person agent distri...

Reviews:

Related manuals for SIMCO CENTURION