SECTION 3  Specifications 

 

Discharge Time*: 

1,000 – 100V < 3 seconds at 12 inches (30.5 cm) 

 

 

 

1,000 – 5V < 5 seconds at 12 inches (30.5 cm) 

Offset Voltage*:

 

±

 3V from set point, set point adjustable to 0V. 

 

OPERATION SPECIFICATIONS 

Max. Current Draw: 

0.6 A 

Line Voltage: 

100-240 VAC, 50/60Hz

 

AC Adapter: 

Universal input 24VDC output with IEC 320 input with grounded 
secondary. 

Coverage Area:

 

1’ x 4’ Area Coverage  

Ambient Temp: 

32

°

 F (0

°

 C) to 122

°

 F (50

°

 C) 

Air Flow Volume: 

Low Fan Speed 50 CFM (23 l/s); High Fan Speed 90 CFM (42 l/s)

 

Audible Noise:

 

Low Fan Speed 48 dB(A); High Fan Speed 58 dB(A) measured 2ft.  
(61 cm) from unit.

 

OFF/ON: 

Rear panel ON/OFF switch 

Fan Speed: 

Adjusted using a potentiometer adjustment tool. Adjustment located on 
the rear panel of the unit.  

Offset Balance: 

Adjustable to zero, using a potentiometer adjustment tool. Adjustment 
access is located (recessed) on the rear panel of the unit.  

Indicators: 

A green light indicates power on.  

Fault light is normally off. A red light indicates an error condition. 
(Optional: audible signal) 

Reset: 

Automatic 

Maintenance:

 

Rotate emitter cleaner knob clockwise one revolution and release. 

 

MECHANICAL SPECIFICATIONS 

 

Emitters: 

Machined tungsten 

Enclosure:

 Aluminum 

Finish:

 

 

Gloss white polyester 

Dimensions:  

9 1/2 x 8 x 3 3/8 inches (24 x 20 x 9cm)

 

Total Weight: 

4.25 lbs.  (1.9 kg.) 

Mount:

 

Stainless steel stand

 

Approvals Pending:

  UL, CUL and CE 

 

* Tested in accordance with ESD-STM3.1-2000, IONIZATION. Tested at 12 inches (30.5cm) on centerline

 

Summary of Contents for SIMCO CENTURION

Page 1: ...single fan DC ionizer offers superior balance performance with its novel emitter array design and high gain dual feedback circuitry The Centurion eliminates static charges cleanly quickly and reliably...

Page 2: ...made to the output of the emitter array are seen promptly as ion output changes in the air The resulting balanced stream of ionized air is delivered to the work area to provide static neutralization...

Page 3: ...an Speed Adjusted using a potentiometer adjustment tool Adjustment located on the rear panel of the unit Offset Balance Adjustable to zero using a potentiometer adjustment tool Adjustment access is lo...

Page 4: ...e unit in flammable volatile or explosive atmosphere 6 Do not insert objects through the unit s intake or outlet grilles Damage to the ionizer and or personal injury may result SECTION 5 Installation...

Page 5: ...ize static is dependent on the fan speed setting For fastest charge neutralizing performance the unit should be adjusted for the highest fan speed The Ion Balance adjustment located on the rear of the...

Page 6: ...removal from its pivot pins The emitters are installed in sockets for easy insertion and removal Using a long nose pliers pull the emitters out along the radial direction gripping the shaft only takin...

Page 7: ...n no event shall SIMCO be liable for incidental or consequential damages except where state laws override This warranty extends to the original purchaser and is not transferable No person agent distri...

Reviews:

Related manuals for SIMCO CENTURION