Connect wires to supply/grounding wires using connectors as shown below.
Attach th
e safety cable
with (H3) 3/16 * 1-1/2 inch wood screw +Ф5.5xФ25xT1.5 lock washer to the ceiling .
Conductor of a fan identified as grounded conductor to be connected to a grounded conductor of
power supply, conductor of fan identified for equipment grounding to be connected to an
equipment-grounding conductor.
After making the wire connections, the wire should be spread apart with the grounded conductor
(neutral Wire) and the equipment-grounding conductor (Ground Wire) on one side of the outlet box and
the ungrounded conductor (Live Wire) on the other side of the outlet box.
The splices after being made should be turned upward and pushed carefully up into the oulet box.
Warning
1. This appliance must be grounded.
2. This product must be installed by a certified electrician in accordance with local codes.
3. Check to see that all connections are tight, including ground, and that no bare wire is
visible at the wire connectors. Do not operate fan until the blades are in place. Noise and
motor damage could result.
For cUL only