5. Sufficient air is needed for proper combustion and exhausting of 

gases through the flue (chimney) of fuel burning equipment to 

prevent excessive low pressure and to prevent back drafting. Follow 

the heating equipment to guidelines and safety standards such as 

those published by the National Fire Protection Association (NFPA), 

and the American Society for Heating, Refrigeration and Air 

Conditioning Engineers (ASHRAE), and the local code authorities. 

 

6. When cutting or drilling into wall or ceiling, do not damage 

electrical wiring and other hidden utilities. 

 

7. The wiring must be permanent. DO NOT USE EXTENSION CORD! 

Although the Powered Gable Ventilator may be wired directly to 

power, we advise that some type of shut off switch be installed on 
the line. Please see the section on electrical wiring for suggested 

wiring diagrams and instructions.

 

8. For general ventilating use only. Do not use this fan to exhaust 

hazardous or explosive materials or vapors.

 

9. To avoid motor bearing damage and noisy and/or unbalanced 

impellers, keep drywall spray, construction dust, etc. off power unit.

 

10. Ensure that the power source conforms to the electrical 

requirements of the fan.

 

11. Always disconnect power before inspection or cleaning, as motor 

may restart unexpectedly.

 

12. In cases in which property damage may result from malfunction of 

the fan, a suitable alarm (air switch, temperature sensor, etc.) 

should be used.

 

 
 

 

Summary of Contents for ILG001TH

Page 1: ...1 Humidity Thermostat control box for Attic Gable Ventilator MODEL ILG001TH MODEL ILG002T 120VAC 60Hz Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS...

Page 2: ...2 TABLE OF CONTENTS Important Instructions 3 Installing Instructions 6 Operating Instructions 8 Maintenance and Cleaning 8 Troubleshooting 9...

Page 3: ...s to the electrical requirements of the fan All wiring must be in accordance with National Electrical Code ANSI NFPA 70 1999 2 Use this unit only in the manner intended by the manufacturer If you have...

Page 4: ...EXTENSION CORD Although the Powered Gable Ventilator may be wired directly to power we advise that some type of shut off switch be installed on the line Please see the section on electrical wiring for...

Page 5: ...nstalling or servicing the fan Failure to do so may result in fatal electrical shock WARNING Do not insert fingers or foreign objects into the fan Do not block or tamper with the fan in any manner whi...

Page 6: ...itch must be turned off before servicing since the built in thermal protection may turn on the circulator automatically 1 Mount the control box on the adjacent rafter 2 Connect the Black and White wir...

Page 7: ...7 Wiring Diagram for ILG001TH...

Page 8: ...8 Wiring Diagram for ILG002T...

Page 9: ...move fan while it is in operation Product Specifications MAINTENANCE AND CLEANING WARNING Parts replacement and troubleshooting to be performed only by qualified personnel WARNING Do not depend on any...

Page 10: ...r circulator TROUBLESHOOTING If your fan fails to operate please follow these Instructions 1 Make sure the fan is well connected and the electrical line in is working properly 2 Check for any obstruct...

Page 11: ...u to visit our service related website www ilivingusa com for troubleshooting tips and service instructions if needed Register your product at our website Or visit iLivingUSA com register product Feed...

Page 12: ...12 iLIVING USA 9293 Beatty Dr Sacramento CA 95826 Tel 1 800 317 1688 Email service ilivingusa com...