6
PERFORMANCE CHECKLIST
All burners are tested before leaving the factory. There are no adjustments for the burners
if connected according to the information on the rating plate. Check each burner for proper
operations. Flames should be blue in all settings. If service is required, contact your dealer for
the name of their authorized service agency. Gas conversions and initial installation are not
responsibility of the manufacturer.
The installer should carry out the following performance checks. Refer to instructions below.
1. Check surface burner ignition.
2. Check air shutter adjustment sharp blue fl ame, no yellow tipping, shooting or fl ame lifting.
3. Check low fl ame adjustment
4. Check for gas leaks (odors) at all gas connections.
R E Q U I R E M E N T S
R o o m v e n t i l a t i o n – L o c a t i o n a n d v e n t i n g .
AT T E N T I O N : A e x h a u s t f a n m a y b e u s e d w i t h t h e a p p l i a n c e ; i n e a c h c a s e i t s h a l l b e i n s t a l l e d i n c o n f o r m i t y w i t h t h e
n a t i o n a l s t a n d a r d s i n f o r c e .
AT T E N T I O N : E x h a u s t h o o d o p e r a t i o n m a y a f f e c t o t h e r v e n t e d a p p l i a n c e s ; i n e a c h c a s e i t s h a l l b e i n s t a l l e d i n c o n f o r m i t y
w i t h t h e n a t i o n a l s t a n d a r d s i n f o r c e .
C O N V E R S I O N T O D I F F E R E N T T Y P E S O F G A S
A n y c o n v e r s i o n r e q u i r e d m u s t b e p e r f o r m e d b y y o u r d e a l e r o r a q u a l i f i e d l i c e n s e d p l u m b e r o r g a s s e r v i c e c o m p a n y.
P l e a s e p r o v i d e t h e s e r v i c e p e r s o n w i t h t h i s m a n u a l b e f o r e w o r k i s s t a r t e d o n t h e r a n g e . ( G a s c o n v e r s i o n s a r e t h e
r e s p o n s i b i l i t y o f t h e d e a l e r o r e n d u s e r. )
WA R N I N G
T h i s c o nve r s i o n k i t s h a l l b e i n s t a l l e d by a q u a l i f i e d s e r v i c e a g e n c y i n a c c o r d a n c e w i t h t h e
m a nu fa c t u r e r ’s i n s t r u c t i o n s a n d a l l a p p l i c a bl e c o d e s a n d r e q u i r e m e n t s o f t h e a u t h o r i t y h av i n g
j u r i s d i c t i o n . I f t h e i n fo r m a t i o n i n t h e s e i n s t r u c t i o n s i s n o t fo l l owe d ex a c t l y, a f i r e, ex p l o s i o n o r
p r o d u c t i o n o f c a r b o n m o n ox i d e m ay r e s u l t c a u s i n g p r o p e r t y d a m a g e, p e r s o n a l i n j u r y o r l o s s o f l i fe.
T h e q u a l i f i e d s e r v i c e a g e n c y i s r e s p o n s i bl e fo r t h e p r o p e r i n s t a l l a t i o n o f t h i s k i t . T h e i n s t a l l a t i o n
i s n o t p r o p e r a n d c o m p l e t e u n t i l t h e o p e ra t i o n o f t h e c o nve r t e d a p p l i a n c e i s c h e cke d a s s p e c i f i e d
i n t h e m a nu fa c t u r e r ’s i n s t r u c t i o n s s u p p l i e d w i t h t h e k i t .
C AU T I O N
B e fo r e p r o c e e d i n g w i t h t h e c o nve r s i o n , s h u t o f f t h e g a s s u p p l y t o t h e a p p l i a n c e p r i o r t o d i s c o n n e c t i n g
t h e e l e c t r i c a l p owe r.
T h e a p p l i a n c e i s s u p p l i e d f o r u s e w i t h a c e r t a i n t y p e o f g a s ; i f t h i s h a s t o b e v a r i e d , y o u m u s t c h a n g e t h e b u r n e r
i n j e c t o r s , a d j u s t t h e a i r f l o w r a t e a n d t h e m i n i m u m g a s f l o w.
B e f o r e c a r r y i n g o u t t h e s e o p e r a t i o n s y o u m u s t d i s c o n n e c t t h e e l e c t r i c p o w e r s u p p l y o f t h e g a s c o o k t o p t o a v o i d
a c c i d e n t a l c o n t a c t s .
B e f o r e c a r r y i n g o u t a n y m a i n t e n a n c e w o r k , d i s c o n n e c t t h e a p p l i a n c e f r o m t h e g a s a n d e l e c t r i c s u p p l y.
3. Flexible Connections:
1. If the unit is to be installed with fl exible couplings and/or quick disconnect fi ttings, the installer must use an heavy
duty, AGA design-certifi ed commercial fl exible connector of at least ½”(1.3cm)ID NPT(with suitable strain relieves)
in compliance with ANSI Z21.41 and Z21.69 standards.
2. In Massachusetts: The unit must be installed with a 36” (3-foot) long fl exible gas connector.
3. In Canada: CAN 1-6.10-88 metal connectors for gas appliances and CAN 1-6.9M79 quick disconnect device for
use with gas fuel.
CAUTION: Leak testing of the appliance shall be conducted according to the manufacturer’s instructions. Before placing the
gas cooktop into operation, always check for leaks with a soapy water solution of other acceptable method. DO NOT USE AN
OPEN FLAME TO CHECK FOR LEAKS!
Summary of Contents for DUHP765N
Page 17: ...17...
Page 20: ...20...
Page 21: ...21...
Page 24: ...24 ELECTRICAL AND GAS POWER TABLE...
Page 25: ...25 NOTES...
Page 26: ...26 NOTES...
Page 27: ...27 NOTES...