I N S TA L L AT I O N   I N S T R U C T I O N S

This appliance shall only be installed by an authorized person. This appliance shall be installed in 
accordance with the manufactures installation instructions, 

IMPORTANT:

 this appliance must be installed in 

accordance with the norms in force of the country concerned.

The installation of this appliance must conform to local codes and ordinances. In the absence of local codes. 
Installations must conforms to American National Standards, National Fuel Gas Code ANSI Z223.1-54

If local codes permit, a fl exible metal appliance connection with the new AGA or CGA certifi ed design, 
max. 5 feet (1,5m) long, ½” I.D. recommended for connecting this cooktop to the gas supply line. Do not 
bend or damage the fl exible connector when moving the cooktop. The pressure regulator has ½” female 
pipe thread. You will need to determine the fi tting required, depending on the size of your gas supply line, 
the fl exible metal connector and the shutoff valve.

The appliance , when installed, must be electrically grounded in accordance with local codes or, in absence 
of local codes, with the National Electrical Code, ANSI/NFPA 70.

The correct voltage, frequency and amperage must be supplied to the appliance from a dedicated, 
grounded circuit which is protected by a properly sized circuit breaker or time delay fuse.The proper 
voltage, frequency and amperage ratings are listed on the product rating plate.

The appliance and its individual shut off valve must be disconnected from the gas supply piping system 
any pressure testing of that system at test pressure in excess of ½psi (3,5kPa).

The appliance must be isolated from the gas supply piping system by closing its individual manual shutoff 
valve during any pressure testing of the gas supply piping system at test pressure equal to or less than 
½psi (3,5kPa).

For use with a pressure regulator. The regulator supplied must be used with this appliance; it shall be 
properly installed in order to be accessible when appliance is installed in defi nitive position.

The gas appliance pressure regulator must be set for the gas with which the appliance is used.

This appliance can be used with Natural gas and LP Gas. It is shipped from the factory adjusted for use 
with Natural gas: CONVERSION FIXED ORIFICES ARE LOCATED IN THE LITERATURE PACK SUPPLIED 
WITH THE UNIT.

Injectors kit for the change of type of gas are contained inside the package jointly with the hob installation 
kit and Instruction booklet. The maximum inlet gas supply pressure incoming to the gas appliance pressure 
regulator is 20” water column (5kPa). The minimum gas supply pressure for checking the regulator setting 
shall be at least 1”w.c.(249Pa) above the inlet specifi ed manifold pressure to the appliance (this operating 
pressure is 5”w.c. for Natural Gas and 10”w.c. for LP Gas). All opening and holes in the wall and fl oor, back 
and under the appliance shall be sealed before installation of the appliance.

ATTENTION: A manual valve shall be installed in an accessible location in the gas line external to the appliance for the 
purpose of turning on or shutting off gas to the appliance.

WARNING: Do not use aerosol sprays in the vicinity of this appliance while it is in operation.

The appliances should not be installed with a ventilation system that blows air downward toward the range.

A ventilation hood is recommended(but not required) for use with the gas cooktop.

Summary of Contents for DUHP765N

Page 1: ...HP1265 FD FDN UHP765 UHP765N UHP765 D DN WARNING If the information in this manual is not followed exactly a fine or explosion may result causing property damage personal injury or death Do not store...

Page 2: ...turer will not be responsible for any damage to property or to persons caused by incorrect installation or improper use of the appliance The manufactured reserves the right to make changes to its prod...

Page 3: ...onents may be hot enough to cause burns Never leave this appliance unattended when in use Boilovers and greasy spills may smoke or ignite Do not heat unopened food containers such as baby food jars an...

Page 4: ...Pa The appliance must be isolated from the gas supply piping system by closing its individual manual shutoff valve during any pressure testing of the gas supply piping system at test pressure equal to...

Page 5: ...T handle type manual gas valve must be installed in the gas supply line to this appliance Refer to the illustration 2 Pressure Regulator 1 All heavy duty commercial type cooking equipment must have a...

Page 6: ...iction If the information in these instructions is not followed exactly a fire explosion or production of carbon monoxide may result causing property damage personal injury or loss of life The qualifi...

Page 7: ...fice must be fully screwed in To convert the regulator Fig 1 and Fig 2 for use with the other gas different from which one it is pre arranged it is enough perform the following operations 1 Unscrew by...

Page 8: ...TURAL A 10500 145 2700 Open Adj TC NATURAL A 15500 180 4000 Open Adj Dual NATURAL A 15500 165 68 6300 15 external Open inner ring Adj Dual aux only NATURAL A 2300 68 800 Open Adj Griddle NATURAL A 105...

Page 9: ...t is small and thin Move sleeve R forward B Flame with lack of air it is irregular with yellow streaks Move sleeve R backward C Normal flame its colour is light blue Figure 3 Figure 4 Figure 6 DUAL Fi...

Page 10: ...ust not be used for heating purposes IMPORTANT correct positioning of the brass flame distributor d Fig 7 is very important For this purpose ensure that the flame distributor tooth e Fig 7 coincides w...

Page 11: ...to reignite the burner turn the knob in a clockwise direction past the limit stop until you reach the required level SURFACE BURNERS Before lighting place the burner head and cap on each burner base...

Page 12: ...l cooking is available as an optional accessory Some models are supplied with the spatula shown in Figure 9 which is useful both for cooking and for cleaning the plate CLEANING AND CARING FOR THE FRY...

Page 13: ...pending on the quantity and temperature of the food the type of gas and of course your own personal taste COOKING TABLE purely indicative values after 10 preheating with the burner at maximum power Kn...

Page 14: ...illustration below Reinsert the cooktop into the countertop opening Lift the entire cooktop to make adjustments Attach the brackets to the bottom of the unit Insert the clamping screws into the bracke...

Page 15: ...natural and LP gas If a flexible metal connector is used be sure the tubing is not kinked Open the shut off valve in the gas supply line Wait a few minutes for the gas to move through the line GAS LE...

Page 16: ...to combustible vertical surfaces above 36 91 4 cm the maximum wall cabinet depth must be 13 33 0 cm and wall cabinets within this 8 20 3 cm side clearance must be 18 45 7 cm above the 36 91 4 cm high...

Page 17: ...17...

Page 18: ...P765 UH965 UHP1265 A hole of 1 31 32 5 cm x 5 cm must be done on the top for power cable and gas conduit as shown in picture The supplied feet h 0 5 16 0 8 cm must be fitted in the special holes under...

Page 19: ...13 33 0 cm and wall cabinets within this 8 20 3 cm side clearance must be 18 45 7 cm above the 36 91 4 cm high countertop Within the 16 40 64 cm side clearance to combustible vertical surfaces above...

Page 20: ...20...

Page 21: ...21...

Page 22: ...HP65 C CN D DN UHP75 C CN D DN UHP95 PC PCN PD PDN FC FCN FD FDN C CN D DN UHP1230 D DN UHP125 PC PCN PD PDN FC FCN FD FDN UHF40 UHF40N UHF40 F FN D DN UHP665 UHP665D UHP965 UHP965 F FD PD 6 6D UHP126...

Page 23: ...3 UXLP90F UXLP90FD LEGEND M Terminal board MA Electrical ignition microswitch EL Valve DS1 Electronic controller 00 Black 22 Red 33 White 45 Green 66 Blue K1 Earth wire terminal board N Neutral L Phas...

Page 24: ...24 ELECTRICAL AND GAS POWER TABLE...

Page 25: ...25 NOTES...

Page 26: ...26 NOTES...

Page 27: ...27 NOTES...

Page 28: ...COOKERS OVENS HOB COOKERS INDUSTRIA LAVORAZIONE VENETA ELETTRODOMESTICI S p A Via Antoniana 100 35011 Campodarsego PD Italy Tel 39 049 9200990 Fax 39 049 9201010 mail ilve com www ilve com...

Reviews: