SETTING PROCESSING TEMPERATURES

Press CLEAR, then 2 TEMP SET and follow the
instructions for setting the solution and dryer
temperatures, use the numbers on the keypad to
input data. Press ENTER, then CONFIRM then
CLEAR. The dryer minimum temperature is 45°C
(113°F).
The processing temperatures for ILFORD chemistry
can be checked on the control panel. Press 9 TEMP
DISPLAY to show the set and actual temperatures.

PROGRAMMING OPERATING TIMES

The date and time can be set using the control
panel, press CLEAR , then press 6 TIMER SET and
follow the instructions.
The processor can be programmed to automatically
re-start at a pre-set time so that the solutions reach
operating temperatures for the start of a day’s work.
Press CLEAR, then press 6 TIMER SET and follow the
instructions. To set the days you want the timer to
operate, press 0 for off, 1 for on.

DRAINING

Remove lower panel, withdraw bottle. Remove top
cap assembly. Remove drain cap and fit nozzle,
pour out the effluent. Refit caps, replace bottle and
refit panel. Each working tank can be drained by
opening the appropriate drain valve. Place a bottle
under the drain pipe (Dev or  Fix) when draining
dev tank or fix tank. Water from the other tanks
goes to the main drain via the drain tray.

ADDING SOLUTIONS

Ensure the drain valves are closed. Unscrew and
withdraw the filter element assembly. Pour solution
into the temperature control tank as shown until
solution in the working tank overflows to the drain.
Refit the filter assembly.

Developer working tank capacity 

- 10 litres

Fix working tank capacity 

- 13 litres

Rinse solution working tank capacity  - 4 litres

Each replenishment bottle holds 10 litres of solution,
top up as required.

Summary of Contents for ILFOLAB FP40

Page 1: ...une 1998 ILFORD Imaging UK Limited Mobberley Cheshire AIR PUMP ADJUSTMENTS The air pump controls air flow through the water in tank WS1 Remove rack 3 to see the amount of agitation With DRIVE on rotate the air pump adjusting knob clockwise to decrease the flow of air counter clockwise to increase the flow EMERGENCY PROCEDURES If the drive stops with a film in the processor fit the handle and turn ...

Page 2: ...ILFOLAB FP40 processor CONTROL PANEL Forward through sequence Back through sequence ENTER Record the new input data CONFIRM Verify the input data to memory CLEAR Clears the display shows the present state of the processor Press CLEAR at the start and end of each programming sequence POWER Switches the processor systems on DRIVE Switches on drive motor air pump and dryer TIMER Select for automatic ...

Page 3: ...M will power the pump through one complete cycle Power the pump through 5 cycles Take an average reading of the total volume to find the actual rate adjust the rate if required and check again Replenishment pump flow rates and operating times Rep volume Approximate rep time seconds ml 36 exp Fixer Developer and rinse solution 10 2 4 3 3 20 4 8 6 6 30 7 2 9 9 40 9 6 13 2 50 12 0 16 5 60 14 4 20 8 7...

Page 4: ... 6 TIMER SET and follow the instructions To set the days you want the timer to operate press 0 for off 1 for on DRAINING Remove lower panel withdraw bottle Remove top cap assembly Remove drain cap and fit nozzle pour out the effluent Refit caps replace bottle and refit panel Each working tank can be drained by opening the appropriate drain valve Place a bottle under the drain pipe Dev or Fix when ...

Reviews: