background image

 

  8

 

 

 
5.

 

Record 

 

Click 

  in Tool Bar then go to Record page. In Record page please configure all parameters to fulfill your requirements. Enter advanced page to get more option. 

Record quality level definition “Best 768Kbps” / “Better 640Kbps” / “High 512Kbps” / “Low 384Kbps”. “User-defined” ranges from 32kbps to 2048kbps. 
Record frame rate levels define as “Full / 12 / 6 / 3 / 1 / User-defined” for PAL or “Full / 15 / 7 / 3 / 1 / User-defined” for NTSC. Default is “Full” means 25 fps for PAL or 30 fps for 
NTSC. 
Record Resource “Video” means record video only. “Video & Audio” means record video and audio. 

Sub-stream 

can be enabled or disabled. After enabled, press <ok> to set sub-stream frame rate and bit rate. Sub stream frame rate rages from 1 to 15 frames, bit rate ranges from 

32K to 512K. 

Select VIDEO CH then click button 

  to enter Record Schedule setup interface. Record types include 4 kinds of schedule record “common record” / “Motion record” / “Alarm 

record” / “Motion and Alarm record”. 
 

Common record 

Common record means continuous record. DVR will always record when it is power on. 

 
Motion record 

If you has setup Motion Record, please continuously go to Video page to setup motion detect sensitivity and area for each camera. 

 
Alarm record 

If you setup Alarm record, you have to integrate alarm-in and relay out device such as Infra red sensor, otherwise it wouldn’t work properly. Please set alarm camera, alarm type 
and trigger event in Alarm page. Trigger event includes record, PTZ preset, alarm out, buzzer and Email. 
Alarm type includes N.O., N.C. 

N.O.: Normally open. Circuit connected when alarm single triggered. 
N.C.: Normally connected. Open when alarm single triggered. 

Notes: In order to execute the Alarm Trigger Record, please set the record schedule firstly. If you need execute Alarm trigger PTZ, please don’t forget to save PTZ preset besides 
herein settings. Currently only preset #1 could be linked to alarm trigger. 

 

 
Motion and Alarm record 

DVR will record only when both Motion detect and Alarm-in are triggered in same time. It wouldn’t record if either one happen. 

Summary of Contents for IL6004HB

Page 1: ...Quick Reference Guide For IL6000HB Series NetDVR...

Page 2: ...l of Product 3 3 Software Main Interface 4 3 1 Log in 5 3 2 Camera Status Icon 5 3 3 System status bar 5 3 4 System Tool Bar 6 4 System Menu Structure 7 5 Record 8 6 Playback 8 7 Record Backup 9 8 PTZ...

Page 3: ...l Support many kinds of PTZ protocol Support preset sequence and tour Alarm Local alarm includes exception and motion detection Alarm pops up full screen image Alarm linkage triggered record linkage a...

Page 4: ...upport remote voice talk 16 Audio input interface RCA Linear Electrical Level Resistance 600 Audio output 1 channel RCA Linear Electrical Level Resistance 600 support remote voice talk Audio compressi...

Page 5: ...Press and hold on 3 seconds to force shut down 3 LED Indicator PW Power indicator Turn red when plug in power cable 5 Hard Disk Drive Please use dashpot gasket to fix the HDD HDD Hard disk indicator B...

Page 6: ...IN 8 channel video input BNC 1Vp p 75 5 TV OUT BNC 1Vp p 75 6 VGA resolution 800 600 60Hz 1024 768 60Hz 1280 1024 60Hz 1440 900 60Hz 1600 1200 60Hz 1680 1050 60Hz 1920 1080 60Hz 7 AUDIO OUT 1 channel...

Page 7: ...ates alarm trigger recording Turquoise indicates manual recording The external alarm input and alarm output status icon shown on system Tool Bar The details are as following The upper row of icons ind...

Page 8: ...ht click mouse will exit or cancel current operation Enter system menu Begin Stop manual record Enter playback Enter PTZ operation panel Cancel alarm alert Click this button will pop up a message to s...

Page 9: ...7 4 System Menu Structure...

Page 10: ...d Motion and Alarm record Common record Common record means continuous record DVR will always record when it is power on Motion record If you has setup Motion Record please continuously go to Video pa...

Page 11: ...Stop Adjust forward playing speed 1X 8x 16x 1 2X and 1 4X are available Frame play button Click to move to next frame Switch split view mode 7 Record Backup In above Search interface click Backup but...

Page 12: ...t number move PTZ to aim position and adjust zoom focus iris click to save this preset Up to 16 presets are supported Call preset steps Choose preset number click button to call it Delete preset steps...

Page 13: ...r System Menu Return 5 Direction Key Select and confirm Move PTZ direction in PTZ mode 6 Function Key 1 screen and 4 screen switch Set Tour Call Preset Tour 7 PTZ Function Key PTZ Menu Set Preset Auto...

Page 14: ...up down Start stop audio spy Start stop local record Grab image save to default folder Webclient2 Stop preview For your attention web client local record only supports manual record Device Parameters...

Page 15: ...upports all kinds of video devices include NetDVR PC DVR IP Camera Megapixel Camera IP Video Server and IP speed dome There is no limitation of transmission distance no limitation of monitors and came...

Page 16: ...fill in this form in order to get prompt technical service in case of emergency Item Description NetDVR Model Name NetDVR serial number Firmware Version Purchasing date Dealer s Contact info Company n...