background image

P a g e

 | 

www.ikikiuas.fi 

Read through these instructions carefully before installation and use.  
 

This instruction manual is intended for the owner of the sauna, or the person responsible 

for the sauna’s maintenance and upkeep. The manual must be handed over to the owner 

after installation has been completed. 

 

Save these instructions for later use. 

 

 

 

When choosing the place for the stove, carefully calculate the appropriate safety distances 
to combustible materials. 

 

Ensure the floor’s load bearing capacity and check the requirements for the flue connection 
pipe (angled or straight), or the installation route of a new metal chimney pipe. 

 

Read through the instructions carefully before installation and use.  

 

 

ATTN! Use protective gloves and a long-sleeved shirt when handling the 

stove’s mesh frame and when placing the stones into the stove as there 

may be rough edges in the frame

.  

 

 

 

 

 

Contact information 

 

 

 

 

 

 

 

Technical support 

(Mon-Fri 9-16) 
+ 358 (0)600 550 133  
(1,49 €/min + lnc) 
[email protected] 

IKI Kiuas Plc 

Hakaniemenkatu 11 
00530 Helsinki, Finland 
[email protected] 

Production , Pieksämäki 

Niilontie 10 
76150 Pieksämäki, Finland 
[email protected] 

Helsinki Warehouse 

Pälkäneentie 5 
00510 Helsinki, Finland 
[email protected] 

Summary of Contents for KIVI-IKI SL

Page 1: ...Instructions for installation and use KIVI IKI SL fireplace sauna stove Instructions for installation and use 4 2021 ...

Page 2: ...and check the requirements for the flue connection pipe angled or straight or the installation route of a new metal chimney pipe Read through the instructions carefully before installation and use ATTN Use protective gloves and a long sleeved shirt when handling the stove s mesh frame and when placing the stones into the stove as there may be rough edges in the frame Contact information Technical ...

Page 3: ...istances to flammable structures 7 3 4 Through the wall installation 7 3 5 Measurements and height for a 90 degree angled stove pipe 8 4 VENTILATION AND COMPENSATION AIR 9 5 INSTALLATION OF THE STOVE 10 5 1 Installation 10 5 2 Affixing the glass hatch 12 6 INSTRUCTIONS FOR USE 13 6 1 Lighting the fire 13 6 2 Care and upkeep 14 6 3 Trouble shooting 14 6 4 Instruction for sweeping 15 6 5 Protective ...

Page 4: ...ces and the stones during and after use as they may be extremely hot If you are required to touch them use thermal protection gloves Pay special attention to safety when children are bathing in the sauna When installing the stove and replacing stones watch out for any sharp edges in the frame wear protective gloves and a long sleeved shirt In addition to this manual the installation and use of the...

Page 5: ...placed with new ones at least once a year Proof must be presented at request such as a receipt for the purchase of the product a receipt for the construction site or a similar statement The use of ceramic heater stones other than those form KERKES is prohibited If such stones have been used the manufacturer ceases to honour the warranty 4 The warranty does not cover dismantlement or reinstallation...

Page 6: ...ng should be placed around the product IKI Kiuas Plc recommends using the original packaging which has been designed for safe transport 10 IKI Kiuas Plc is not responsible for any damage caused during transportation if the products have been packaged carelessly The costs caused by an error or negligence on the part of the customer will be charged from the customer If returns are made without reaso...

Page 7: ...fed and the floor s load bearing capacity Note that IKI stoves hold a lot of stones which weight a lot IKI wood burning stoves should ideally be installed into either a brick chimney a ceramic chimney or an air cooled chimney The outer diameter of the stove outlet pipe is 115 mm 3 2 Preheating and commissioning the stove Before laying the stones or bathing for the first time preheat the stove outs...

Page 8: ... the glass hatch to the front 500 mm The required distance for safety can be cut down by 50 when using fire protection boards for example 1 mm metal fibre board with a 30 mm air gap 3 4 Through the wall installation The thickness of the wall can be max 150 mm The front of the furnace has to be at least 40 mm away from the wall in order for the hatch to open up properly The safety distance to a fla...

Page 9: ... measures 670 mm x 448 mm B A stove with an IKI stove baseplate Wall protecting heat shield measures 740 mm x 448 mm The height of the stove base is 70 mm Wall protecting heat shields are available in black and stainless steel NOTE When ordering the heat shield you need to know whether you intend to use a stove base as this determines the size of the shield If the stove will be connected to the IK...

Page 10: ...sure the air inlets do not get obstructed Exhaust air is led out of the sauna preferably through a hole equipped with a disc valve and an adjustable grid placed between the lower and upper benches The exhaust air should flow through a metal channel inside the wall and to exit just below the roof on the outer wall The exhaust vent can also be in the ceiling or near the ceiling on the wall opposite ...

Page 11: ...he stove pipe on top of the stove check that chimney connection pipe is in place and make sure the stove is horizontally level PIC 5 8 Install the heat shield around the hole on the other side of the wall PIC 6 The shield can be affixed with heat resistant glue or screws 9 Insert the ash pan in place and affix the hatch making sure that the hatch has room to open PIC 7 Reposition the stove as need...

Page 12: ...P a g e 11 www ikikiuas fi ...

Page 13: ...hatch to the front of the furnace There are appropriate holes in place for the hinge bolts PIC 2 Screw in the bolt nuts and tighten them from the inner side of the hatch Note The bushings should be installed between the neck and the hinge outer side of the neck PIC 1 PIC 2 ...

Page 14: ...e steady level Note The handle on the hatch might get hot as the stove heats up Use the protective gloves included in the delivery to open the hatch as needed In the beginning as you build the fire the ash pan can be slightly ajar to provide a draft for the fire During bathing and when the sauna room has warmed up the ash pan can be closed or the gap narrowed down in order to control the fire and ...

Page 15: ...below and attempt to solve them THE PROBLEM HOW TO SOLVE IT No draft in the stove 1 Check the chimney for blockages e g bird s nest and make sure the damper is open 2 Has the chimney been swept accordingly 3 Is there a low pressure air front Burn some paper in the furnace first keeping the hatch open 4 Check firewood is dry The draft is too strong 1 Adjust the draft 2 If the chimney pipe is high u...

Page 16: ...of the pipe and cause early corrosion 4 The pipe can alternatively be cleaned using an industrial vacuum cleaner 5 Finally spray or pour some water and or use the brush to clean up the detachable smoke pipe Features of the water Effect Recommendation Humus content Colour taste precipitation 12 mg l Iron in the water Colour smell taste precipitation 0 2 mg l Hardness The main ingredients manganese ...

Page 17: ...lacing the stones into the stove as there may be rough edges in the frame Prolonged stay in a hot sauna raises the body temperature which can be dangerous Be careful with the hot stove The stones and metal parts heat up to burning hot Do not throw water on to the stove if anyone is close to the stove The hot steam can cause severe burns Prevent children from going near the stove Do not leave child...

Page 18: ..._________________________ ____________________________________________________________ ____________________________________________________________ ____________________________________________________________ ____________________________________________________________ ____________________________________________________________ ____________________________________________________________ ________...

Page 19: ...P a g e 18 www ikikiuas fi ...

Page 20: ...P a g e 19 www ikikiuas fi Copyright IKI Kiuas Plc We reserve the right to make changes ...

Reviews: