5. Advance Use
External Synchronization
To use this machine in external synchronization mode, input SYNC to the
GENLOCK terminal on the CCU back. When SYNC is input to the GENLOCK
terminal, the camera will enter external synchronization mode from internal
synchronization mode automatically.
SYNC input conditions: 3-value SYNC: 0.6 Vp-p / 75
ƺ
5.1.1 Wiring Example
Prepare two sets of the CCU and camera for MKC-750UHD. Connect the
SYNC connector on the CCU (master) and the GENLOCK connector on the CCU
(slave) with each other, using a coaxial cable.
㻯㻯㼁㻔䝬䝇䝍䞊䠅
㻯㻯㼁㻔䝇䝺䞊䝤䠅
䜹䝯䝷㻔䝇䝺䞊䝤䠅
䜹䝯䝷㻔䝬䝇䝍䞊䠅
㻿㼅㻺㻯㻌䝁䝛䜽䝍
㻳㻱㻺㻸㻻㻯㻷㻌䝁䝛䜽䝍
CCU (master)
Camera (master)
Camera (slave)
CCU (slave)
SYNC connector
GENLOCK connector