MKC-307 0710 VOL1(U)(E)
20
DTL Set
DTL ON
DTL Gain
0
Skin DTL Color
Skin
Skin DTL Gain
0
Slim DTL
OFF
[Manual Shutter]
This product is normally used with this function set to
OFF. It is changed using the [<] and [>] buttons when
the user wishes to use it with a specific electronic
shutter speed.
[AE Level Set]
The brightness can be fine-adjusted when the Manual
Shutter is set to OFF and either or both of the Shutter
Button
ԥ
and the Gain Button
Ԧ
on the CCU front
panel are set to ON. This operation is the same as using
the brightness Adjustment Control Knob
Ԛ
.
[AE Speed]
The response speed for the electronic shutter and
automatic sensitivity can be selected as either Middle,
Fast or Slow.
[Peak Ratio Set]
The method of setting up the optical measurement for
the electronic shutter and automatic sensitivity operation
is switched. The optical measurement with maximum
value can be set by using the + direction and the
average value by using the – direction.
[Area Select]
The optical measurement area can be selected as either
Middle, Wide, Full, SP Narrow and Narrow.
[AGC Max Gain]
The maximum sensitivity during automatic sensitivity
operation is selected as either X2 (+6dB) or X4 (+12dB).
[Slow
Shutter
Limit]
The maximum shutter speed during slow shutter
operation is selected as either 1/4, 1/8, 1/15 or 1/30.
DTL Set
Sets up outline enhancement.