- 59 -
a) Characters: ASCII
(alphanumeric);
Max. of 8 characters in 7
colors
b) Display position: Top or bottom
(7) USB memory function
a) Content of the memory
MENU setting
User marker
PRESET data
Full capture image
b) Stored image
No. of stored images: Max. 32 images
Resolution: 280
720
File format:
Binary file for exclusive
use of the monitor
Data capacity: 3~4 MB
7-5
㧚
Remote Control
(1) Parallel remote control
Input connector: HD D-SUB 15-pin
CH A/B switching
SDI ON/OFF
COLOR/MONO switching
4:3/16:9 switching
MARKER ON/OFF
SHADOW ON/OFF
R TALLY ON/OFF
G TALLY ON/OFF
SHADOW0 ON/OFF (
ڎ
)
SHADOW20 ON/OFF (
ڎ
)
SHADOW40 ON/OFF (
ڎ
)
SHADOW60 ON/OFF (
ڎ
)
* For the pin function, refer to ""Data 3 Par-
allel Remote Pin Function".
* In addition to default setting, user setting is
possible.
The “
ڎ
” marked settings are used in the
USER mode.
(2) Serial remote control
(The controller SRC-301A/Z is discontinuation.)
Input/output terminal:
BNC 1 lines (Loop through)
Input level
1.9Vp-p, Negative polarity
Input impedance
High impedance bridge connection or 75
termination
* For the control items, refer to ""Data 2 Con-
trol with Remote Controller".
(3) RS-485 remote control (customized)
Connector: RJ-45 (loop-through)
Maximum number of connections: 32 units
Additional lines will allow up to 126 monitors for
each ID setting and monitor control.
8. Applicable Standards
8-1
㧚
Safety standards
UL1419
EN60950-1
8-2
㧚
Electromagnetic interference
FCC
Class-A
EN55103-1
E4
EN55103-2
E4
8-3
㧚
Environmental regulations
Compliant with RoHS Directive