IKA 35 828 25 Operating Instructions Manual Download Page 3

3

072010

Page

Safety instructions

3

Unpack

4

Correct use

4

Commissioning

5

Error codes

6

Accessories

6

Maintenance

6

Warranty

7

Technical data

8

To your protection

• Read the operating instructions in full before starting up

and follow the safety instructions.

Keep the operating instructions in a place where they can be
accessed by everyone.

Ensure that only trained staff work with the appliance.

Follow the safety instructions, guidelines, occupational health
and safety and accident prevention regulations.

Socket must be earthed (protective ground contact).

• Attention - Magnetism!

Effects of the magnetic field have

to be taken into account (e.g. data cardiatic, carriers pacema-
kers...).

• Risk of burns! 

The heating plate temperature can exceed

500 °C. Pay attention to the residual heat after switching off.
Please make sure that the mains cable does not contact the
heating plate

Wear your personal protective equipment in accordance with the
hazard category of the medium to be processed. Otherwise
there is a risk of:
- splashing liquids
- projectile parts

- release any toxic or combustable gases.

Set up the appliance in a spacious area on an even, stable, clean, 
non-slip, dry and fireproof surface.

The feet of the appliance must be clean and undamaged.

Position the knob at the left stop before starting up. Gradually

increase the speed.

Reduce the speed if

- the medium splashes out of the vessel because the speed is too high
- the appliance is not running smoothly
- the container moves on the set-up surface.

Never heat up any medium with fire point lower (min. 50°C)

than the adjusted temperature 

When using PTFE-coated magnetic bars, the following hase
to be noted: 

Chemical reactions of PTFE occur in contact with

molten or dissolved alkaline and alkaline - earth metals, as well
as with fine-particled powders of metals of the 2. and 3. group
of the periodical system at temperatures above  300-400°C.
Only elementary fluorine, chlorine trifluoride und alkaline metals
do attack PTFE, halogen hydrocarbons have a reversibly swelling
effect.

Check the appliance and accessories beforehand for damage

each time you use them. Do not use damaged components.

Only replace damaged parts with spare parts identical to the ori

ginal in function and quality.

Do not use the device if the ceramic set-up surface is damaged
e.g. scratches, splinters or corrosion. A damaged set-up surface 
could break if used.

Beware of the risk of

- flammable materials
- glass breakage as a result of mechanical shaking power
- incorrect container size
- too much medium
- unsafe condition of container

Only process media that will not react dangerously to the extra
energy produced through processing. This also applies to any
extra energy produced in other ways, e.g. through light irradiation.

• Do not

operate the appliance in explosive atmospheres, with

hazardous substances or under water.

Contents

Safety instructions

EN

3582825_C-MAG_072010:35 828 25  7/12/2010  4:03 PM  页 3

Summary of Contents for 35 828 25

Page 1: ...C MAG HS 4 C MAG HS 7 C MAG HS 10 C MAG MS 4 C MAG MS 7 C MAG MS 10 C MAG HP 4 C MAG HP 7 C MAG HP 10 35 828 25 072010 Operating instructions EN 3 CN 9...

Page 2: ...D E Designation Main Switch LED heating plate LED display heating plate Rotary knob heater Rotary knob motor Threaded hole for stand Mains socket Socket contact thermometer Item A B C D E F G H A B C...

Page 3: ...lashes out of the vessel because the speed is too high the appliance is not running smoothly the container moves on the set up surface Never heat up any medium with fire point lower min 50 C than the...

Page 4: ...ed on the nameplate must correspond to the mains voltage Do not cover the device even partially e g with metallic plates or film This results in overheating Protect the appliance and accessories from...

Page 5: ...nd even after the device is disconnected from the power Set the target temperature for the heating plate using operating button D for VHP E The set value is indicated on the display C If energy is bei...

Page 6: ...turbance up is indicated these with the devices to HS and HP by an error message in the display C Whenever an error message appears switch the device off to cool down Error codes Error Cause Solution...

Page 7: ...rn the appliance in its original packa ging Storage packaging is not sufficient Please also use suitable transport packaging In accordance with IKA warranty conditions the warranty period is 12 months...

Page 8: ...ating voltage VAC VAC VAC Nominal voltage VAC VAC VAC Design frequence Hz Input power max at 230 and 120 VAC W 100 VAC Power consumption in stand by mode W Perm duration of operation Perm ambient temp...

Page 9: ...9 072010 500 C 9 10 10 11 12 12 13 13 14 50 C PTFE 300 400 C PTFE PTFE CN...

Page 10: ...10 100 mm 100 mm IKA 100 mm 100 mm...

Page 11: ...11 072010 MS 4 MS 7 MS 10 HS 4 HS 7 HS 10 HP 4 HP 7 HP 10 A G C A C A D C LED B 50 C A DIN 12878 2 C...

Page 12: ...12 072010 HS HP C E1 E6 E9 G 6mm 15mm 8mm 50mm 10mm 80mm RS 1 RSE H 16 V H 16 1 H 38 H 44 ETS D5 F M10 SW17 M10...

Page 13: ...13 072010 IKA www ika net IKA...

Page 14: ...C 5 40 80 DIN 60529 IP 21 I II 2 m max 2000 W x D x H mm 150 x 260 x 105 220 x 335 x 105 300 x 415 x 105 kg 3 5 6 1 min 100 1500 100 1500 100 1500 100 1500 100 1500 100 1500 W 15 15 15 15 15 15 W 1 5...

Page 15: ......

Page 16: ...IKA Works Guangzhou 173 175 510730 Tel 86 20 8222 6771 Tel 86 400 886 0358 Fax 86 20 8208 8373 info ika cn www ika com...