DSXi KVM Extender
24
2011-02-23
5.2
DDC Settings
By default, the device sends the factory preset DDC information to the
CPU. This information is sufficient in most cases.
CPU Unit and CON Unit offer the following DIP switch settings to control
the administration of the DDC information:
CPU Unit
DIP
Function
Switch
Position
Switch down
Switch up
Not used
Send stored DDC information to CPU (default: factory preset
DDC information).
Allow reading of DDC information from the attached monitor.
Reset and only ever send the factory default
DDC information
CON Unit
DIP
Function
Switch
Position
Switch down
Switch up
Not used
Prevent reading of DDC information from the attached
monitor
Allow reading of DDC information from the attached monitor
Reading of DDC information is performed during operation (see
Chapter 6.2, Page 27).
If DIP switch
3
on the CPU Unit is in upper position the CPU will only ever
be sent the factory preset DDC information.