Configuration
2016-02-29
53
5.5.2 Parameters for CON Units
You can write the following parameters into the configuration file of a CON
Unit.
Output Settings
Parameter
Function
1080p50Hz
Always display 50 Hz when using 1920x1080
DISEXTOSD
Deactivate extender OSD
ENAFRAME
Show orange colored frame when losing
extender connection
ENAHOLDPIC
Show last transmitted picture highlighted by an
orange colored frame when losing connection
ENALOSTMR
Activate LOS timer
ENADDCTX
Activate DDC transmission by unplugging and
connecting the monitor back to the CON Unit
CENTERMODE
Simulate the native resolution of Dual-Link
monitors by an additional black frame in order to
enable Instant Switching (482 series only).
PARAM=V
Simultaneous output of DVI-D and VGA signal
(R474-BVHx and R474-BVHxR only)
ENAAUDIO
Enable RS232 or RS422 and analog audio
during video only connetions