Draco (Cross) Repeater
30
2014-04-15
7.4
Power Supply
AC Power Supply
Model
Max. Current
Max. Voltage
Frequency
474-BODY2N
700 mA max.
100-240 V
50/60 Hz
474-BODY6R
1,400 mA max.
100-240 V
47-63 Hz
474-BODY6BP
800 mA max.
100-240 V
50/60 Hz
474-BODY6BPF
800 mA max.
100-240 V
50/60 Hz
474-BODY21/4U
4,000 mA max.
2x 100-240 V
50/60 Hz
DC Power Supply
Model
Max. Current
Max. Voltage
474-BODY2/2R
3,000 mA
5 VDC
474-BODY2N
5,000 mA
5 VDC
474-BODY4/4R
5,000 mA
5 VDC
474-BODY6R
8,000 mA
5 VDC
Power Requirement
Power Requirement
(per Unit)
(Cross) Repeater
:
Max. 300 mA
Pos: 48 /806-IHSE/Technische Daten/Einsatzbedingungen/ATB_Einsatzbedingungen @ 5\mod_1278578980026_6.doc @ 42480 @ 2 @ 1
7.5
Environmental Conditions
Operating Temperature
41 to 113°F (5 to 45°C)
Storage Temperature
–13 to 140°F (–25 to 60°C)
Relative Humidity
Max. 80% non-condensing
Pos: 49 /806-IHSE/Technische Daten/Abmessungen/474-xx @ 6\mod_1304586358176_6.doc @ 51345 @ 2 @ 1