IHP Superior WRE6842RS Assembly, Installation And Operation Instructions Download Page 8

Superiorfireplaces.US.com

127011-01B

8

VENTING INSTALLATION

OPTIONAL OUTSIDE AIR KIT (MODEL AK4/AK4F)

The installation of an outside air kit should be performed during 

the rough framing of the fireplace due to the nature of it's location. 

Outside combustion air is accessed through a vented crawl space 

(AK4F) or through a sidewall (AK4).

 CAUTION: Combustion air inlet ducts shall not 

terminate in attic space.

The maximum height for the air vent can not exceed 

3 feet below the flue gas outlet of the termination.

Figure 7- Outside Air Kit

CHIMNEY PIPE

 WARNING: Label part number 900599-01 must be 

applied by the installer to all chimney pipe sections 

but is not required on sections that will be visible after 

the installation is complete. Label must wrap around 

the circumference of the pipe. See accessories, page 

25 for Kit F2659.

The IHP chimney system consists of 12", 18", 24", 36" and 48" snap-

lock, double-wall pipe segments, planned for maximum adaptability 

to individual site requirements. Actual lengths gained after fitting 

overlaps  must  be  taken  into  consideration  (lineal  gain)  and  are 

given in the lineal gain chart (see Figure 8). Lineal Gain is the actual 

measurable length of a part after two or more parts are connected. 

For Canada, use chimney parts designated "HT".

 WARNING: The opening in the collar around the 

chimney at the top of the fireplace must not be ob-

structed. Never use blown insulation to fill the chimney 

enclosure.

Figure 8- Lineal Gain

LINEAL GAIN

PART NO.

DESCRIPTION

GAIN

Signature

Fireplace

66 

1

/

2

"

12-12DM

12-12HT

Pipe Section

10 

5

/

8

"

18-12DM

18-12HT

Pipe Section

16 

5

/

8

"

24-12DM

24-12HT

Pipe Section

23 

5

/

8

"

36-12DM

36-12HT

Pipe Section

34 

5

/

8

"

48-12DM

48-12HT

Pipe Section

46 

5

/

8

"

RLT-12D

RLT-12HT

Round Termina

-

tion

3

/

4

"*

STL-12D

Square Chase-

Top with Slip 

Section

7" to 15"*

* The lineal gain for the terminations is measured to 

the flue gas outlet height.

Hemmed 

End

12 

3

/

8

Stainless 

Inner Pipe

15" Galvanized 

Outer Pipe

ASSEMBLY AND INSTALLATION OF DOUBLE WALL CHIMNEY 

SYSTEM

Each double wall chimney section consists of a galvanized outer pipe, 

a stainless steel inner flue pipe and a wire spacer. The pipe sections 

must be assembled independently as the chimney is installed. When 

connecting chimney directly to the fireplace, the inner flue pipe section 

must be installed first with the lanced side up. The outer pipe section 

can then be installed over 5 the flue pipe section with the hemmed 

end up. Press down on each pipe section until the lances securely 

engage the hem on the fireplace starter. The wire will assure the proper 

spacing between the inner and outer pipe sections.

Continue to assemble chimney sections as outlined above, making 

sure that both the inner and outer pipe sections are locked together. 

When installing double wall snap-lock chimney together, it is impor-

tant to assure the joint between the chimney sections is locked. Check 

by pulling chimney upward after locking. The chimney will not come 

apart if properly locked. It is not necessary to add screws to keep the 

chimney together (exception, see Figure 9, page 9).

The height of a vertical chimney pipe supported 

ONLY

 by the fire-

place, must not exceed 20 feet. Chimney heights above 20 feet must 

be supported.

Secure to Collars with Metal Tape, Screws 

or Straps (Min. of 1/4" x 20" in size)

Air Inlet 

Location 

Must Allow 

For Bushes 

or Snow

Vent Hood 

Required 

for Wall 

Installation

Air Inlet 

Eyebrow

Vented 

Crawl Space 

(Check Local 

Codes Before 

Installing in a 

Vented Crawl 

Space)

Summary of Contents for Superior WRE6842RS

Page 1: ...er approved to ANSI Z21 11 2 standard FOR CANADA The authority having jurisdiction such as the municipal building department fire department etc should be contacted before installation to determine th...

Page 2: ...iquids in the vicinity of this or any other appliance Due to high temperatures the appliance should be located out of traffic and away from furniture and draperies Do not place clothing or other flamm...

Page 3: ...insects and fungus When burned thesechemicalscanposeasignificanthazard WARNING BURNINGIMPROPERFUEL I E CHAR COAL CAN RESULT IN CARBON MONOXIDE POISON ING WHICH MAY LEAD TO DEATH Carbon Monoxide Poison...

Page 4: ...d 42 MODEL 22 3 4 30 1 2 29 4 3 8 15 3 4 5 8 17 5 8 67 61 49 7 1 30 11 58 42 51 1 8 4 1 2 3 1 2 9 1 2 10 1 2 81 2 13 17 OUTSIDE AIR ACCESS GAS LINE ACCESS 42 HEARTH 1 1 4 23 Ref 41 3 8 26 3 8 21 3 4 F...

Page 5: ...inued 50 MODEL Figure 2 50 Models WRT6850RS WRT6850IS WRT6850RH and WRT6850IH 38 1 2 28 1 2 43 8 17 5 8 19 1 4 24 49 30 11 61 67 58 7 1 59 50 4 1 2 3 1 2 9 1 2 10 1 2 8 1 2 13 17 GAS LINE ACCESS OUTSI...

Page 6: ...ation is 9 5 feet minimum of 4 feet of chimney pipe sections required for outdoor installation FRAMING 1 Frame opening for fireplace using dimensions shown in Figures 3 and 4 2 If fireplace is to be i...

Page 7: ...terial see Figure 5 WARNING Hearth extension is to be installed only as shown in Figure 5 Figure 5 Hearth Extension Seal Gap Fireplace Front Ember Protector Fireplace Front Raised Hearth Fireplace Fro...

Page 8: ...2HT Pipe Section 34 5 8 48 12DM 48 12HT Pipe Section 46 5 8 RLT 12D RLT 12HT Round Termina tion 7 3 4 STL 12D Square Chase Top with Slip Section 7 to 15 The lineal gain for the terminations is measure...

Page 9: ...ombinations of 12 18 24 36 and 48 length of double wall pipe see offset chart and Figure 9 2 Chimney weight above offset rests on return elbow Straps must be securely nailed to rafters or joists see F...

Page 10: ...uired at each point where the chimney penetrates a floor space Their purpose is to establish and maintain the required clearance between the chimney and the combustible materials When the pipe passes...

Page 11: ...DM 19 5 Min 30 Min 2 Min 2 Min 2 Min Opening A Figure 14 Roof Opening Measurements Nail Only Outer Perimeter of Flashing Storm Collar Flashing Cone Underlap Shingles at Bottom Overlap Shingles Top and...

Page 12: ...be sure to provide adequate distance between terminations to prevent smoke spillage from one termination to another We suggest that terminations be separated at least 24 center to center and stacked...

Page 13: ...Installing Hearth and Leading Brick panels Hearth Panel Side leading brick Panel 2 Install the left and right firebrick walls There is a bracket with 2 tabs on the bottom of each firebrick wall Angle...

Page 14: ...et add equal parts cement and sand Add enough water and mix together well using a power drill with mixing wand attachment to a yogurt like consistency Not adding enough water can lead to grout falling...

Page 15: ...ated WARNING Whenusingadecorativeventedgaslog the damper must be removed or permanently locked in the fully open position and the glass doors must be in the fully open position Gas line hook up should...

Page 16: ...zardous condition INSTALLING GLASS DOORS Spring clips have been installed but some adjustments may be needed Install the doors using the following steps 1 With bifold doors completely folded insert bo...

Page 17: ...will provide sufficient combustion air and maintain safe temperatures in firebox IMPORTANT The glass must be allowed to warm slowly and evenly The tempered glass will withstand a gradual temperature...

Page 18: ...t provides secondary combustion for the wood burning process MAINTENANCE The PureFire System is a maintenance free technology Do not attempt to remove or clean the combustor The direct flame from the...

Page 19: ...r consequential damages arising out of the improper use of this product or the continued use of this product beyond the required replacement period TECHNICAL SERVICE You may have further questions abo...

Page 20: ...S MODELS 42 AND 50 1 21 20 5 6 7 10 9 11 12 13 16 17 15 14 8 24 23 3 25 18 2 22 19 4 26 27 28 29 30 MODEL CATALOG NO WRE6842RS F0421 WRE6842IS F0422 WRE6842RH F0423 WRE6842IH F0424 WRE6850RS F0425 WRE...

Page 21: ...PACER CLEARANCE 36 42 50 6 13 J5329 BRACKET F P HANDLE 4 14 J6900 PLATE OUTSDE AIR COVER 36E44 6 2 15 J6934 COVER GAS CONDUIT PLATE 36E 4 16 J4368 GAS CONDUIT ONE 2 17 J4369 GAS CONDUIT TWO 2 18 HEAT...

Page 22: ...fireplaces US com 127011 01B 22 1 6 4 8 7 3 2 5 7 7 7 8 9 PARTS MODEL CATALOG NO WRE6842RS F0421 WRE6842IS F0422 WRE6842RH F0423 WRE6842IH F0424 WRE6850RS F0425 WRE6850IS F0426 WRE6850RH F0427 WRE6850...

Page 23: ...L CUT FSB42I 1 J6477 ASSY RT PANEL CUT FRB50I 1 J6469 ASSY RT PANEL CUT FHB42I 1 J6485 ASSY RT PANEL CUT FHB50I 1 6 J6464 ASSY LT PANEL CUT FSB42R 1 J6478 ASSY LT PANEL CUT FRB50R 1 J6470 ASSY LT PANE...

Page 24: ...ction double wall pipe snap lock F0953 12 12HT 12 Section hi temp double wall pipe snap lock F0954 18 12HT 18 Section hi temp double wall pipe snap lock F0955 24 12HT 24 Section hi temp double wall pi...

Page 25: ...ation with louvered screen F0960 RLT 12HT Hi temp round top termination with louvered screen FIRESTOP THIMBLE F0944 FST10 Firestop thimble LABEL UL127 50PK WARNING HOT Fire Risk Insulation and combust...

Page 26: ...Chimney Support F0960 RLT 12HT Round Top w Louvers F0961 AP 12HT Anchor Plate Collar Assembly Masonry Fireplaces F0951 CAK 12 Cold Air Collar Kit When ordered alone this part cannot ship via parcel d...

Page 27: ...e subject to normal use with approved fuels listed in the Operation Manual provided with the product This includes burning such fireplace fuels as wood and natural or propane gas Fuel products with ab...

Page 28: ...lso to discontinue colors styles and products Consult your local distributor for fireplace code information Printed in U S A 2014 IHP LLC P N 127011 01 Rev B 10 2015 P127011 01 1508 Elm Hill Pike Suit...

Reviews: