IHP Superior WRE6842RS Assembly, Installation And Operation Instructions Download Page 6

Superiorfireplaces.US.com

127011-01B

6

FIREPLACE INSTALLATION

SELECTING LOCATION

To determine the safest and most efficient location for the fireplace, 

you must take into consideration the following guidelines:

1.  The location must allow for proper clearances (see Figures 3 and 

4).

2.  Consider a location where fireplace will not be affected by drafts, 

air conditioning ducts, windows or doors.

3.  A location that avoids cutting of joists or roof rafters will make 

installation easier.

4.  An  outside air  kit  is  available  with  this  fireplace  (see  Optional 

Outside Air Kit on page 8).

MINIMUM CLEARANCE TO COMBUSTIBLES

Back and sides of fireplace                                                1 

1

/

2

" min.*

Ceiling                                                                                 42" min.

Front of fireplace                                                                 48" min.
Floor**                                                                                   0" min. 
Perpendicular wall to opening                                                18" min.

Top spacers                                                                            0" min.
Mantel clearances                                                see Mantels, page 7

Chimney outer pipe surface                                                  2" min.

* Not required at nailing flanges

** See step 2 of 

Framing

 WARNING: Do not pack required air spaces with 

insulation or other materials.

Minimum/Maximum Chimney Height for Residential Installation

Minimum height of chimney, measured from base of fireplace to flue 

gas outlet of termination, is 16 feet for straight flue or a flue with one 

elbow set. Maximum distance between elbows is 6 feet. For systems 

with two elbow sets, minimum height is 22 feet. Maximum height of 

any system is 50 feet. This measurement includes fireplace, chimney 

sections and height of termination assembly at level of the flue gas 

outlet (see Figure 14, page 11).

Minimum/Maximum Chimney Height for Outdoor Installation

Minimum height of chimney, measured from base of fireplace to flue 

gas outlet of termination, is 9.5 feet (minimum of 4 feet of chimney 

pipe sections required for outdoor installation).

FRAMING

1.  Frame opening for fireplace using dimensions shown in Figures 

3 and 4.

2.  If  fireplace  is  to  be  installed  directly  on  carpeting,  tile  or  any 

combustible material other than wood flooring, fireplace must 

be installed upon a metal or wood panel extending full width and 

depth of fireplace.

3.  Set fireplace directly in front of this opening and slide unit back 

until nailing flanges touch side framing.

4.  Check level of the fireplace and shim with sheet metal if necessary.

Figure 3 - Framing Dimensions

Figure 4 - Corner Installation

59 

1

/

8

" (50'' Models)

58 

1

/

8

"

30 

1

/

8

"

67 

1

/

8

"

51 

1

/

4

" (42'' Models)

45 

1

/

4

" (36'' Models)

28 

1

/

4

" (36'' Models)

71" (50" Models)

100" (50" Models)

65" (42" Models)

92" (42" Models)

86 

1

/

2

" (36" Models)

61" (36" Models)

Maintain 1 

1

/

2

"

Clearance 

at Sides and 

Back of Fireplace

1

/

2

" Clearance

Not Required at 

Nailing Flanges 

5.  Before securing fireplace to prepared framing, ember protector 

(provided) must be placed between hearth extension (not sup

-

plied) and under bottom front edge of fireplace to protect against 

glowing embers falling through. If fireplace is to be installed on a 

raised platform, a Z-type ember protector (not supplied) must be 

fabricated to fit your required platform height. Ember protector 

should extend under fireplace a minimum of 1 

1

/

2

". Ember protector 

should be made of galvanized sheet metal (28 gauge minimum 

to prevent corrosion.

6.  Using screws or nails, secure fireplace to framing through flanges 

located on sides of fireplace

Note:

 For outdoor installations, fireplace enclosure must allow for 

adequate drainage and fresh air ventilation. It is recommended that 

a sealed, corrosion resistant catch pan with provision for drainage 

be installed under fireplace within fireplace enclosure.

Summary of Contents for Superior WRE6842RS

Page 1: ...er approved to ANSI Z21 11 2 standard FOR CANADA The authority having jurisdiction such as the municipal building department fire department etc should be contacted before installation to determine th...

Page 2: ...iquids in the vicinity of this or any other appliance Due to high temperatures the appliance should be located out of traffic and away from furniture and draperies Do not place clothing or other flamm...

Page 3: ...insects and fungus When burned thesechemicalscanposeasignificanthazard WARNING BURNINGIMPROPERFUEL I E CHAR COAL CAN RESULT IN CARBON MONOXIDE POISON ING WHICH MAY LEAD TO DEATH Carbon Monoxide Poison...

Page 4: ...d 42 MODEL 22 3 4 30 1 2 29 4 3 8 15 3 4 5 8 17 5 8 67 61 49 7 1 30 11 58 42 51 1 8 4 1 2 3 1 2 9 1 2 10 1 2 81 2 13 17 OUTSIDE AIR ACCESS GAS LINE ACCESS 42 HEARTH 1 1 4 23 Ref 41 3 8 26 3 8 21 3 4 F...

Page 5: ...inued 50 MODEL Figure 2 50 Models WRT6850RS WRT6850IS WRT6850RH and WRT6850IH 38 1 2 28 1 2 43 8 17 5 8 19 1 4 24 49 30 11 61 67 58 7 1 59 50 4 1 2 3 1 2 9 1 2 10 1 2 8 1 2 13 17 GAS LINE ACCESS OUTSI...

Page 6: ...ation is 9 5 feet minimum of 4 feet of chimney pipe sections required for outdoor installation FRAMING 1 Frame opening for fireplace using dimensions shown in Figures 3 and 4 2 If fireplace is to be i...

Page 7: ...terial see Figure 5 WARNING Hearth extension is to be installed only as shown in Figure 5 Figure 5 Hearth Extension Seal Gap Fireplace Front Ember Protector Fireplace Front Raised Hearth Fireplace Fro...

Page 8: ...2HT Pipe Section 34 5 8 48 12DM 48 12HT Pipe Section 46 5 8 RLT 12D RLT 12HT Round Termina tion 7 3 4 STL 12D Square Chase Top with Slip Section 7 to 15 The lineal gain for the terminations is measure...

Page 9: ...ombinations of 12 18 24 36 and 48 length of double wall pipe see offset chart and Figure 9 2 Chimney weight above offset rests on return elbow Straps must be securely nailed to rafters or joists see F...

Page 10: ...uired at each point where the chimney penetrates a floor space Their purpose is to establish and maintain the required clearance between the chimney and the combustible materials When the pipe passes...

Page 11: ...DM 19 5 Min 30 Min 2 Min 2 Min 2 Min Opening A Figure 14 Roof Opening Measurements Nail Only Outer Perimeter of Flashing Storm Collar Flashing Cone Underlap Shingles at Bottom Overlap Shingles Top and...

Page 12: ...be sure to provide adequate distance between terminations to prevent smoke spillage from one termination to another We suggest that terminations be separated at least 24 center to center and stacked...

Page 13: ...Installing Hearth and Leading Brick panels Hearth Panel Side leading brick Panel 2 Install the left and right firebrick walls There is a bracket with 2 tabs on the bottom of each firebrick wall Angle...

Page 14: ...et add equal parts cement and sand Add enough water and mix together well using a power drill with mixing wand attachment to a yogurt like consistency Not adding enough water can lead to grout falling...

Page 15: ...ated WARNING Whenusingadecorativeventedgaslog the damper must be removed or permanently locked in the fully open position and the glass doors must be in the fully open position Gas line hook up should...

Page 16: ...zardous condition INSTALLING GLASS DOORS Spring clips have been installed but some adjustments may be needed Install the doors using the following steps 1 With bifold doors completely folded insert bo...

Page 17: ...will provide sufficient combustion air and maintain safe temperatures in firebox IMPORTANT The glass must be allowed to warm slowly and evenly The tempered glass will withstand a gradual temperature...

Page 18: ...t provides secondary combustion for the wood burning process MAINTENANCE The PureFire System is a maintenance free technology Do not attempt to remove or clean the combustor The direct flame from the...

Page 19: ...r consequential damages arising out of the improper use of this product or the continued use of this product beyond the required replacement period TECHNICAL SERVICE You may have further questions abo...

Page 20: ...S MODELS 42 AND 50 1 21 20 5 6 7 10 9 11 12 13 16 17 15 14 8 24 23 3 25 18 2 22 19 4 26 27 28 29 30 MODEL CATALOG NO WRE6842RS F0421 WRE6842IS F0422 WRE6842RH F0423 WRE6842IH F0424 WRE6850RS F0425 WRE...

Page 21: ...PACER CLEARANCE 36 42 50 6 13 J5329 BRACKET F P HANDLE 4 14 J6900 PLATE OUTSDE AIR COVER 36E44 6 2 15 J6934 COVER GAS CONDUIT PLATE 36E 4 16 J4368 GAS CONDUIT ONE 2 17 J4369 GAS CONDUIT TWO 2 18 HEAT...

Page 22: ...fireplaces US com 127011 01B 22 1 6 4 8 7 3 2 5 7 7 7 8 9 PARTS MODEL CATALOG NO WRE6842RS F0421 WRE6842IS F0422 WRE6842RH F0423 WRE6842IH F0424 WRE6850RS F0425 WRE6850IS F0426 WRE6850RH F0427 WRE6850...

Page 23: ...L CUT FSB42I 1 J6477 ASSY RT PANEL CUT FRB50I 1 J6469 ASSY RT PANEL CUT FHB42I 1 J6485 ASSY RT PANEL CUT FHB50I 1 6 J6464 ASSY LT PANEL CUT FSB42R 1 J6478 ASSY LT PANEL CUT FRB50R 1 J6470 ASSY LT PANE...

Page 24: ...ction double wall pipe snap lock F0953 12 12HT 12 Section hi temp double wall pipe snap lock F0954 18 12HT 18 Section hi temp double wall pipe snap lock F0955 24 12HT 24 Section hi temp double wall pi...

Page 25: ...ation with louvered screen F0960 RLT 12HT Hi temp round top termination with louvered screen FIRESTOP THIMBLE F0944 FST10 Firestop thimble LABEL UL127 50PK WARNING HOT Fire Risk Insulation and combust...

Page 26: ...Chimney Support F0960 RLT 12HT Round Top w Louvers F0961 AP 12HT Anchor Plate Collar Assembly Masonry Fireplaces F0951 CAK 12 Cold Air Collar Kit When ordered alone this part cannot ship via parcel d...

Page 27: ...e subject to normal use with approved fuels listed in the Operation Manual provided with the product This includes burning such fireplace fuels as wood and natural or propane gas Fuel products with ab...

Page 28: ...lso to discontinue colors styles and products Consult your local distributor for fireplace code information Printed in U S A 2014 IHP LLC P N 127011 01 Rev B 10 2015 P127011 01 1508 Elm Hill Pike Suit...