IHP Superior WRE6842RS Assembly, Installation And Operation Instructions Download Page 17

Superiorfireplaces.US.com

127011-01B

17

DOOR ADJUSTMENT

Remove doors and slightly loosen lower pivot clips and upper spring 

clips. Replace doors and fully close them. Use 1/8" shims (any mate

-

rial) to level doors. Once proper setting is achieved, carefully open 

doors enough so that you can access spring clips with a phillips 

screwdriver. Tighten screws. See Figure 32.

Figure 31 - Installing Bi-Fold Doors

Spring 

Clip

Insert Pin 

into Spring 

Clip

Pivot 

Hole

Insert 

Bottom 

Pivot Pin 

into Hole

Fold Door 

and Slide 

Top Pins 

Into Track

Figure 32 - Adjusting Bi-Fold Doors

AIR DEFLECTOR AND GLASS DOOR INSTALLATION  

Continued

OPERATION AND MAINTENANCE GUIDELINES  

Continued

OPERATION AND MAINTENANCE GUIDELINES

GLASS DOORS

Glass doors are optional with the fireplace. When fireplace is in opera

-

tion, doors must be fully opened or fully closed position only or a fire 

hazard may be created (see Figure 33).

A fireplace equipped with glass doors operates much differently than a 

fireplace with an open front. A fireplace with glass doors has a limited 

amount of air for combustion.

Excessive heat within the fireplace can result if too large a fire is built or 

if combustion air gate is not completely open. The following tips should 

be followed to assure that both the fireplace and glass door retain their 

beauty and function properly. Both the flue damper and glass doors 

must be fully opened before starting fire. This will provide sufficient 

combustion air and maintain safe temperatures in firebox.

IMPORTANT:

 The glass must be allowed to warm slowly and evenly. 

The tempered glass will withstand a gradual temperature rise to 550° F, 

which is more than a normal fire will generate. Such materials as pitch/

wax laden logs, very dry mill end lumber and large amounts of paper 

or cardboard boxes can create an excessively hot fire and should not be 

burned in this fireplace. Always keep the fire well back from the doors 

and never allow flames to contact the glass.

Figure 33 - Bi-Fold Glass Doors

Doors Fully Closed

Fireplace Front

Doors

Fully Opened

Fireplace Front

 WARNING: Fireplaces equipped with glass doors 

should be operated only with doors fully opened or 

doors fully closed. Doors, if left partly open, may draw 

gas and flame out of the fireplace opening creating 

risks of both fire and smoke.

Cleaning Glass

Clean glass with any commercial glass cleaner or soap and water. Do 

not use any abrasive material to clean glass. Do not clean glass with any 

cool water if glass is still hot from the fire and smoke.

OUTSIDE AIR AND DAMPER HANDLE OPERATION

The damper handle, which opens and closes the damper blade, is 

located in the upper front face of the fireplace. Pushing the handle 

forward and up through the keyway slot will free damper blade to 

automatically open. Pushing the handle forward and down will lock 

damper blade closed (see Figure 34). Damper must be locked in the 

full open position before operating fireplace (see Figure 34).

Figure 34 - Operating Damper Handle

Damper 

Weight

To Close 

Damper

To Open 

Damper

Damper 

Weight

Summary of Contents for Superior WRE6842RS

Page 1: ...er approved to ANSI Z21 11 2 standard FOR CANADA The authority having jurisdiction such as the municipal building department fire department etc should be contacted before installation to determine th...

Page 2: ...iquids in the vicinity of this or any other appliance Due to high temperatures the appliance should be located out of traffic and away from furniture and draperies Do not place clothing or other flamm...

Page 3: ...insects and fungus When burned thesechemicalscanposeasignificanthazard WARNING BURNINGIMPROPERFUEL I E CHAR COAL CAN RESULT IN CARBON MONOXIDE POISON ING WHICH MAY LEAD TO DEATH Carbon Monoxide Poison...

Page 4: ...d 42 MODEL 22 3 4 30 1 2 29 4 3 8 15 3 4 5 8 17 5 8 67 61 49 7 1 30 11 58 42 51 1 8 4 1 2 3 1 2 9 1 2 10 1 2 81 2 13 17 OUTSIDE AIR ACCESS GAS LINE ACCESS 42 HEARTH 1 1 4 23 Ref 41 3 8 26 3 8 21 3 4 F...

Page 5: ...inued 50 MODEL Figure 2 50 Models WRT6850RS WRT6850IS WRT6850RH and WRT6850IH 38 1 2 28 1 2 43 8 17 5 8 19 1 4 24 49 30 11 61 67 58 7 1 59 50 4 1 2 3 1 2 9 1 2 10 1 2 8 1 2 13 17 GAS LINE ACCESS OUTSI...

Page 6: ...ation is 9 5 feet minimum of 4 feet of chimney pipe sections required for outdoor installation FRAMING 1 Frame opening for fireplace using dimensions shown in Figures 3 and 4 2 If fireplace is to be i...

Page 7: ...terial see Figure 5 WARNING Hearth extension is to be installed only as shown in Figure 5 Figure 5 Hearth Extension Seal Gap Fireplace Front Ember Protector Fireplace Front Raised Hearth Fireplace Fro...

Page 8: ...2HT Pipe Section 34 5 8 48 12DM 48 12HT Pipe Section 46 5 8 RLT 12D RLT 12HT Round Termina tion 7 3 4 STL 12D Square Chase Top with Slip Section 7 to 15 The lineal gain for the terminations is measure...

Page 9: ...ombinations of 12 18 24 36 and 48 length of double wall pipe see offset chart and Figure 9 2 Chimney weight above offset rests on return elbow Straps must be securely nailed to rafters or joists see F...

Page 10: ...uired at each point where the chimney penetrates a floor space Their purpose is to establish and maintain the required clearance between the chimney and the combustible materials When the pipe passes...

Page 11: ...DM 19 5 Min 30 Min 2 Min 2 Min 2 Min Opening A Figure 14 Roof Opening Measurements Nail Only Outer Perimeter of Flashing Storm Collar Flashing Cone Underlap Shingles at Bottom Overlap Shingles Top and...

Page 12: ...be sure to provide adequate distance between terminations to prevent smoke spillage from one termination to another We suggest that terminations be separated at least 24 center to center and stacked...

Page 13: ...Installing Hearth and Leading Brick panels Hearth Panel Side leading brick Panel 2 Install the left and right firebrick walls There is a bracket with 2 tabs on the bottom of each firebrick wall Angle...

Page 14: ...et add equal parts cement and sand Add enough water and mix together well using a power drill with mixing wand attachment to a yogurt like consistency Not adding enough water can lead to grout falling...

Page 15: ...ated WARNING Whenusingadecorativeventedgaslog the damper must be removed or permanently locked in the fully open position and the glass doors must be in the fully open position Gas line hook up should...

Page 16: ...zardous condition INSTALLING GLASS DOORS Spring clips have been installed but some adjustments may be needed Install the doors using the following steps 1 With bifold doors completely folded insert bo...

Page 17: ...will provide sufficient combustion air and maintain safe temperatures in firebox IMPORTANT The glass must be allowed to warm slowly and evenly The tempered glass will withstand a gradual temperature...

Page 18: ...t provides secondary combustion for the wood burning process MAINTENANCE The PureFire System is a maintenance free technology Do not attempt to remove or clean the combustor The direct flame from the...

Page 19: ...r consequential damages arising out of the improper use of this product or the continued use of this product beyond the required replacement period TECHNICAL SERVICE You may have further questions abo...

Page 20: ...S MODELS 42 AND 50 1 21 20 5 6 7 10 9 11 12 13 16 17 15 14 8 24 23 3 25 18 2 22 19 4 26 27 28 29 30 MODEL CATALOG NO WRE6842RS F0421 WRE6842IS F0422 WRE6842RH F0423 WRE6842IH F0424 WRE6850RS F0425 WRE...

Page 21: ...PACER CLEARANCE 36 42 50 6 13 J5329 BRACKET F P HANDLE 4 14 J6900 PLATE OUTSDE AIR COVER 36E44 6 2 15 J6934 COVER GAS CONDUIT PLATE 36E 4 16 J4368 GAS CONDUIT ONE 2 17 J4369 GAS CONDUIT TWO 2 18 HEAT...

Page 22: ...fireplaces US com 127011 01B 22 1 6 4 8 7 3 2 5 7 7 7 8 9 PARTS MODEL CATALOG NO WRE6842RS F0421 WRE6842IS F0422 WRE6842RH F0423 WRE6842IH F0424 WRE6850RS F0425 WRE6850IS F0426 WRE6850RH F0427 WRE6850...

Page 23: ...L CUT FSB42I 1 J6477 ASSY RT PANEL CUT FRB50I 1 J6469 ASSY RT PANEL CUT FHB42I 1 J6485 ASSY RT PANEL CUT FHB50I 1 6 J6464 ASSY LT PANEL CUT FSB42R 1 J6478 ASSY LT PANEL CUT FRB50R 1 J6470 ASSY LT PANE...

Page 24: ...ction double wall pipe snap lock F0953 12 12HT 12 Section hi temp double wall pipe snap lock F0954 18 12HT 18 Section hi temp double wall pipe snap lock F0955 24 12HT 24 Section hi temp double wall pi...

Page 25: ...ation with louvered screen F0960 RLT 12HT Hi temp round top termination with louvered screen FIRESTOP THIMBLE F0944 FST10 Firestop thimble LABEL UL127 50PK WARNING HOT Fire Risk Insulation and combust...

Page 26: ...Chimney Support F0960 RLT 12HT Round Top w Louvers F0961 AP 12HT Anchor Plate Collar Assembly Masonry Fireplaces F0951 CAK 12 Cold Air Collar Kit When ordered alone this part cannot ship via parcel d...

Page 27: ...e subject to normal use with approved fuels listed in the Operation Manual provided with the product This includes burning such fireplace fuels as wood and natural or propane gas Fuel products with ab...

Page 28: ...lso to discontinue colors styles and products Consult your local distributor for fireplace code information Printed in U S A 2014 IHP LLC P N 127011 01 Rev B 10 2015 P127011 01 1508 Elm Hill Pike Suit...

Reviews: