background image

2. 

Touch the UP or DOWN Buttons to adjust 

the day of week (press the MODE/SET 

Button or wait for 15 seconds for adjust

-

ment to be accepted, then enter hour of 

day adjustment).

3. Press the UP or DOWN Buttons to 

adjust the hour of the day. The time will 

advance in 1-hour increments; AM and 

PM will change when the hour advances 

to 12:00 midnight and 12:00 noon re-
spectively (press the MODE/SET Button 

or wait for 15 seconds for adjustment to 

be accepted, then enter minute of hour 

adjustment).

4. Press the UP or DOWN Buttons to ad-

just the minute of the hour. The time will 

advance in 1-minute increments (press 

the  MODE/SET  Button  or  wait  for  15 

seconds  and  the  transmitter  will  exit 

Day/Time Setup and return to normal 
operation).

5. 

LCD  Displays  –  when  in  Day/Time 

Setup:

• 

MODE Zone: Blank

• 

ROOM TEMP Zone: Blank

• 

SET TEMP Zone: Bank

•  TIME/PROG Zone: Day of Week, or 

Time of Day will Flash

• 

FLAME Zone: Blank

• 

Program Operation

• 

Touch the TIME/PROG Zone to activate 
or deactivate Program Operation. Touch-
ing the MODE Zone or pressing the 

MODE/SET Button will also deactivate 

Program Operation. When Program Op-

eration is deactivated, the transmitter will 

return to MANUAL OFF Mode.

• 

Program  Operation  will  cycle  fireplace 

ignition ON and OFF based on time set-

tings (2 weekend periods and 2 weekday 

periods) and thermostat settings. Press 

the  MODE/SET  Button  or  wait  for  15 

seconds to advance to each subsequent 

program setting.

• 

Pilot Method (same as Thermostat 
Mode): Continuous/Standing Pilot 
only (Intermittent Pilot Ignition (IPI)/
Spark-to-Pilot not allowed).

• Pilot flame will remain ON when Main 

Flame Cycles ON and OFF.

• 

To enter Program Setup, touch and hold 

the TIME/PROG Zone for 5 seconds.

• 

Program OFF LCD Displays:

• 

MODE Zone: OFF

• 

ROOM TEMP Zone: Measured tempera-
ture is displayed

• 

SET TEMP Zone: Blank

• 

TIME/PROG Zone: Current day indica-

tor,  current  time,  and  Program  status 

(P1- OFF or P2-OFF) is displayed

• 

FLAME Zone: Blank

• 

Program ON LCD Displays:

• 

MODE Zone: THERMO and either ON 
or OFF is displayed

• 

ROOM TEMP Zone: Measured tempera-
ture is displayed

• 

SET TEMP Zone: SET TEMP is dis-
played

• 

TIME/PROG Zone: Current day indica-

tor,  current  time,  and  Program  status 

(P1- ON or P2-ON) is displayed

• 

FLAME Zone:

 If Thermostat is ON, A Flame Icon and 

flame setting level number is displayed.
 If Thermostat is OFF, display is blank.

Program Disable Feature

• 

The Program Mode (described above) 

may be disabled for applications where 

a  program  operation  is  not  allowed  or 

undesirable. When Program Mode is 
Disabled:

• The  user  will  not  be  able  to  activate 

Program Mode

• The  user  will  not  be  able  to  enter 

Program Setup or edit Program Mode 
settings.

• The TIME/PROG zone will continue to 

display the Clock and Day of week, but 

none of the icons associated with Pro

-

gram Mode will be displayed.

• 

To disable or re-enable the Program 

Mode, the transmitter must be in MAN

-

UAL  OFF  Mode,  then  touch  and  hold 

the TIME/PROG Zone and the DOWN 
Button simultaneously for 10-seconds. 

The  LCD  screen  will  go  blank  except 

either PROGRAM and OFF (OFF display 
in MODE Zone) or PROGRAM and ON 

(ON  display  in  MODE  Zone)  will  flash 

3-times (0.5-seconds OFF, 0.5-seconds 

Summary of Contents for SKYTECH J7675

Page 1: ...luminate the backlight will not respond to associated zone function To activate any command the backlight for the screen must be on and the command must be touched before the backlight goes off Powered via four AAA sized batteries 6V nominal with LOW BATIERY INDICATOR 5 OV Touch Screen LCD and Button Layout Not to scale SET TEMP Zone FLAME Zone CHANNEL UNLOCK Zone MODE Zone I CHANNEL PROG Zone 1 _...

Page 2: ...OF OPERATION OPERATION MODES MANUAL OFF MANUAL ON THERMOSTAT with optional PRO GRAM Mode The modes may be cycled in the order above by touching the MODE Zone or pressing the MODE SET Button MANUAL OFF MODE Transmits flame OFF command Pilot Method Intermittent Pilot Ignition IPI Spark to Pilot only continuous standing pilot not allowed Pilot flame will be turned OFF LCD Displays MODE Zone OFF is di...

Page 3: ...t day indicator and current time is displayed FLAME Zone Blank THERMOSTAT ON LCD Displays MODE Zone THERMO and ON are displayed ROOM TEMP Zone Measured tempera ture is displayed SET TEMP Zone SET TEMP is dis played TIME PROG Zone Current day indicator and current time is displayed FLAME Zone A Flame Icon and flame setting level number is displayed Thermostat Disable Feature The Thermostat Mode des...

Page 4: ...de Continuous Standing Pilot only Intermittent Pilot Ignition IPI Spark to Pilot not allowed Pilot flame will remain ON when Main Flame Cycles ON and OFF To enter Program Setup touch and hold the TIME PROG Zone for 5 seconds Program OFF LCD Displays MODE Zone OFF ROOM TEMP Zone Measured tempera ture is displayed SET TEMP Zone Blank TIME PROG Zone Current day indica tor current time and Program sta...

Page 5: ...ON THERMOSTAT ON mode and PROGRAM ON modes If the room tem perature reaches 95 deg F or greater the transmitterwill automatically change to MANUAL OFF mode and send a MANUAL OFF command to the control module If the user turns the control back ON and the room temperature is still 95F or greater the transmitter will switch to back manual OFF and send another OFF command the next time the transmitter...