background image

to change the SET TEMP (45-90 deg. F, 

7-32 deg. C); the new set temperature 

will  automatically  be  accepted  after  2 

seconds. The factory default SET TEMP 
is 68 deg. F.

• 

SWING Temperature: This model does 

not allow for SWING temperature adjust

-

ment. This  model  utilizes  thermostatic 

flame  modulation  that  will  modulation 

the main flame based on the difference 

between room temperature and set tem

-

perature (see example below).

• 

Important - factory SWING TEMPERA-
TURE setting is 2 degrees. The thermo-

static flame modulation feature will not 

allow this SWING to be changed.

EXAMPLE:

Set Temperature     Room Temp.     Flame Level

                                        74F                   OFF

                                        73F                   Level 1

Set Temperature (72)

 

  72F                   Level 2

                                        71F (or less)     Level 3

• 

Pilot Method: Continuous/Standing Pilot 
only (Intermittent Pilot Ignition (IPI)/

Spark-to-Pilot not allowed).

• 

Pilot flame will remain ON when Main 

Flame Cycles ON and OFF.

• 

Manual  Flame  Adjustment  while  in 

THERMOSTAT mode: If Flame-A is 

manually  adjusted  while  in  thermostat 

mode,  it  will  override  the  automatic 

flame setting until the flame cycles off, 

then  back  ON  thermostatically;  when 

the  flame  cycles  ON  again,  automatic 

flame adjustment will resume. Automatic 

flame adjustment will also resume if the 

operational mode is cycled out of, then 

back into THERMOSTAT mode or if the 
SET temperature is changed.

• 

THERMOSTAT OFF LCD Displays:

• 

MODE Zone: THERMO and OFF is 
displayed

• 

ROOM TEMP Zone: Measured tempera-
ture is displayed

• 

SET TEMP Zone: SET TEMP is dis-
played

• 

TIME/PROG Zone: Current day indicator 
and current time is displayed

• 

FLAME Zone: Blank

• 

THERMOSTAT ON LCD Displays:

• 

MODE Zone: THERMO and ON are 
displayed

• 

ROOM TEMP Zone: Measured tempera-
ture is displayed

• 

SET TEMP Zone: SET TEMP is dis-
played

• 

TIME/PROG Zone: Current day indicator 
and current time is displayed

• FLAME Zone: A Flame Icon and flame 

setting level number is displayed

Thermostat Disable Feature

• 

The Thermostat Mode (descr bed above) 

may be disabled for applications where a 

thermostat is not allowed or undesirable. 

When Thermostat Mode is Disabled:

• The  Modes  of  operation  will  cycle  be

-

tween MANUAL ON and MANUAL OFF 

(omitting THERMO).

• Program Operation (described below) is 

also disabled.

• The SET TEMP zone will be blank.
• The room temperature will still be mea

-

sured & displayed in the ROOM TEMP 

Zone.

• The TIME/PROG zone will continue to 

display the Clock and Day of week, but 

none of the icons associated with Pro

-

gram Mode will be displayed.

• 

To disable or re-enable the Thermostat, 

the transmitter must be in MANUAL 

OFF  Mode,  then  touch  and  hold  the 

SET TEMP Zone and the DOWN Button 
simultaneously for 10- seconds. The 

LCD screen will go blank except either 

THERMO and OFF or THERMO and 

ON will flash 3-times (0.5-seconds OFF, 

0.5-seconds ON) to indicate the change 
has been made.

DAY AND TIME DISPLAY

• 

The  current  day  of  week  and  time  of 

day will be continuously displayed in the 

TIME/PROG Zone (except during Setup 
operations).

• 

The  day  of  week  will  be  displayed  as 

one of the following: S, M, T, W, T, F, S

• 

The time of day will be in 12-hour AM, 

12-hour  PM  format.  Midnight  will  be 

displayed as 12:00am.

• 

Day/Time Setup:

1. Press and hold the MODE Zone for 5 

seconds to enter Day/Time Setup.

Summary of Contents for SKYTECH J7675

Page 1: ...luminate the backlight will not respond to associated zone function To activate any command the backlight for the screen must be on and the command must be touched before the backlight goes off Powered via four AAA sized batteries 6V nominal with LOW BATIERY INDICATOR 5 OV Touch Screen LCD and Button Layout Not to scale SET TEMP Zone FLAME Zone CHANNEL UNLOCK Zone MODE Zone I CHANNEL PROG Zone 1 _...

Page 2: ...OF OPERATION OPERATION MODES MANUAL OFF MANUAL ON THERMOSTAT with optional PRO GRAM Mode The modes may be cycled in the order above by touching the MODE Zone or pressing the MODE SET Button MANUAL OFF MODE Transmits flame OFF command Pilot Method Intermittent Pilot Ignition IPI Spark to Pilot only continuous standing pilot not allowed Pilot flame will be turned OFF LCD Displays MODE Zone OFF is di...

Page 3: ...t day indicator and current time is displayed FLAME Zone Blank THERMOSTAT ON LCD Displays MODE Zone THERMO and ON are displayed ROOM TEMP Zone Measured tempera ture is displayed SET TEMP Zone SET TEMP is dis played TIME PROG Zone Current day indicator and current time is displayed FLAME Zone A Flame Icon and flame setting level number is displayed Thermostat Disable Feature The Thermostat Mode des...

Page 4: ...de Continuous Standing Pilot only Intermittent Pilot Ignition IPI Spark to Pilot not allowed Pilot flame will remain ON when Main Flame Cycles ON and OFF To enter Program Setup touch and hold the TIME PROG Zone for 5 seconds Program OFF LCD Displays MODE Zone OFF ROOM TEMP Zone Measured tempera ture is displayed SET TEMP Zone Blank TIME PROG Zone Current day indica tor current time and Program sta...

Page 5: ...ON THERMOSTAT ON mode and PROGRAM ON modes If the room tem perature reaches 95 deg F or greater the transmitterwill automatically change to MANUAL OFF mode and send a MANUAL OFF command to the control module If the user turns the control back ON and the room temperature is still 95F or greater the transmitter will switch to back manual OFF and send another OFF command the next time the transmitter...

Reviews: