background image

127195-01C

3

IHP.us.com

Figure 4 - Removing/Replacing Main Burner Orifi ce

CONVERSION INSTRUCTIONS

Burner Orifi ce Conversion

1.  Using a #10 short phillips screwdriver, remove top mounting screw 

holding pilot burner shield in place 

(see 

Figure 4

)

.

2. With 

orifi ce mount exposed, use a 7/8” open-end back-up wrench 

on 3/8” fl are adaptor and remove 3/8” fl are fi tting at the end of 3/8” 
fl are adaptor. This will prevent spinning and damage to the fl exible 
tube 

(see 

Figure 4

)

.

3.  Using the 7/8” wrench, remove the remaining orifi ce assembly from 

the burner tube.

4.  Separate the 3/8” male fl are adaptor from the existing natural gas 

orifi ce fi tting and save for later reassembly.

5.  Thread the propane/LP gas orifi ce into the propane/LP gas air-mixer 

fi tting using a 3/8” deep socket driver. 

NOTE

: LP gas airmixer fi tting 

has six (6) holes. The natural gas fi tting has no holes.

6.  Apply a light amount of propane/LP resistant sealant to both threaded 

ends of LP air-mixer fi tting.

7.  Thread large threaded end of propane/LP air-mixer fi tting into burner 

tube and tighten with 7/8” wrench until fl ange is fully-seated into 
bracket.

8.  Replace 3/8” fl are adaptor onto exposed thread on propane/LP 

gas air-mixer fi tting. Use 7/8” back-up wrench on fi tting to prevent 
turning burner tube.

9.  Retighten fl are fi tting on fl exible manifold tube with the 3/4” open-

end wrench and 7/8” back-up wrench.

10. Reattach pilot shield onto burner bracket with screw removed in 

step 1.

3/8" Deep Socket

Propane/LP
Gas Orifice 

Propane/LP 
Gas Air-
Mixer Fitting

3/8" Flare Fitting

Natural Gas
Orifice Fitting 

Burner 
Bracket

Flange

Burner 
Tube

7/8" Back-Up 

Wrench

Pilot Burner 
Shield

#10 Phillips 
Screw

3/8" Flare 
Adaptor

Gas Control Valve Conversion

Convert the gas control by swapping out the valve regulator portion of 
the gas valve.

1.  Using a Torx T20 or slotted screwdriver, remove and discard the 

three mounting screws, pressure regulator tower, and diaphragm/
spring components 

(see 

Figure 5

).

2.  Ensure that the rubber gasket is properly positioned on the new pres-

sure regulator assembly. Install LP pressure regulator assembly to 
valve using the new mounting screws supplied with the kit. Tighten 
screws securely (@ approximately 25 in-lbs.) 

(see 

Figure 6

).

3. Install 

the 

identifi cation label enclosed with the gas valve regulator 

to the valve body, where it can easily be seen 

(see 

Figure 6

)

.

Figure 5 - Removing Mounting Screws, Pressure Regulator 
Tower, and Diaphragm/Spring Components

Figure 6 - Installing Pressure Regulator Assembly

Mounting 
Screws

Pressure 
Regulator 
Tower

Diaphragm/
Spring 
Components

Mounting 
Screws

Rubber Gasket

Identification Label 

f i r e - p a r t s . c o m

Summary of Contents for PCBE-36

Page 1: ...ING This conversion kit shall be installed by a qualified service agency in accordance with the manufac turer s instructions and all applicable codes and requirements of the authority having jurisdiction If the information in these instructions is not followed exactly a fire explosion or production of carbon monoxide may result causing property damage personal injury or loss of life The qualified ...

Page 2: ...e installer and adhered to the appliance at the time of the conversion Contact your local gas supplier for deration requirements for your area CAUTION The gas supply shall be shut OFF prior to discon necting the electrical power before proceeding with the conversion ATTENTION Avant d effecteur la conversion coupez d abord l alimentationengaz ensuite coupezl alimentation electrique Figure 1 Removin...

Page 3: ...rench on fitting to prevent turning burner tube 9 Retighten flare fitting on flexible manifold tube with the 3 4 open end wrench and 7 8 back up wrench 10 Reattach pilot shield onto burner bracket with screw removed in step 1 3 8 Deep Socket Propane LP Gas Orifice Propane LP Gas Air Mixer Fitting 3 8 Flare Fitting Natural Gas Orifice Fitting Burner Bracket Flange Burner Tube 7 8 Back Up Wrench Pil...

Page 4: ...d Figure 9 Conversion Information Label CONVERSION INFORMATION LABEL This appliance was converted on ___ ___ ___ to ______________ gas with Kit No _______________________ by _____________________________ _____________________________ _____________________________ name and address of organization making this conversion which accepts the responsibility that this conversion has been properly made 106...

Page 5: ... appliance owner s manual WARNING Test all gas piping and connections for leaks after installation or servicing Correct leaks at once WARNING Never use an open flame to check for a leak Apply noncorrosive leak detection fluid to all joints Bubbles forming show a leak Correct all leaks at once Figure 11 Inspect for Proper Burner Flame Appearance No Blue Flame Center Soot at Flame Tip Dark Orange Fl...

Page 6: ...___________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ __________________________________________________...

Page 7: ...___________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ __________________________________________________...

Page 8: ...P reserves the right to make changes at any time without notice in design materials specifica tions prices and also to discontinue colors styles and products Consult your local distributor for fireplace code information 1508 Elm Hill Pike Suite 108 Nashville TN 37210 fire parts com ...

Reviews: