127195-01C
3
IHP.us.com
Figure 4 - Removing/Replacing Main Burner Orifi ce
CONVERSION INSTRUCTIONS
Burner Orifi ce Conversion
1. Using a #10 short phillips screwdriver, remove top mounting screw
holding pilot burner shield in place
(see
Figure 4
)
.
2. With
orifi ce mount exposed, use a 7/8” open-end back-up wrench
on 3/8” fl are adaptor and remove 3/8” fl are fi tting at the end of 3/8”
fl are adaptor. This will prevent spinning and damage to the fl exible
tube
(see
Figure 4
)
.
3. Using the 7/8” wrench, remove the remaining orifi ce assembly from
the burner tube.
4. Separate the 3/8” male fl are adaptor from the existing natural gas
orifi ce fi tting and save for later reassembly.
5. Thread the propane/LP gas orifi ce into the propane/LP gas air-mixer
fi tting using a 3/8” deep socket driver.
NOTE
: LP gas airmixer fi tting
has six (6) holes. The natural gas fi tting has no holes.
6. Apply a light amount of propane/LP resistant sealant to both threaded
ends of LP air-mixer fi tting.
7. Thread large threaded end of propane/LP air-mixer fi tting into burner
tube and tighten with 7/8” wrench until fl ange is fully-seated into
bracket.
8. Replace 3/8” fl are adaptor onto exposed thread on propane/LP
gas air-mixer fi tting. Use 7/8” back-up wrench on fi tting to prevent
turning burner tube.
9. Retighten fl are fi tting on fl exible manifold tube with the 3/4” open-
end wrench and 7/8” back-up wrench.
10. Reattach pilot shield onto burner bracket with screw removed in
step 1.
3/8" Deep Socket
Propane/LP
Gas Orifice
Propane/LP
Gas Air-
Mixer Fitting
3/8" Flare Fitting
Natural Gas
Orifice Fitting
Burner
Bracket
Flange
Burner
Tube
7/8" Back-Up
Wrench
Pilot Burner
Shield
#10 Phillips
Screw
3/8" Flare
Adaptor
Gas Control Valve Conversion
Convert the gas control by swapping out the valve regulator portion of
the gas valve.
1. Using a Torx T20 or slotted screwdriver, remove and discard the
three mounting screws, pressure regulator tower, and diaphragm/
spring components
(see
Figure 5
).
2. Ensure that the rubber gasket is properly positioned on the new pres-
sure regulator assembly. Install LP pressure regulator assembly to
valve using the new mounting screws supplied with the kit. Tighten
screws securely (@ approximately 25 in-lbs.)
(see
Figure 6
).
3. Install
the
identifi cation label enclosed with the gas valve regulator
to the valve body, where it can easily be seen
(see
Figure 6
)
.
Figure 5 - Removing Mounting Screws, Pressure Regulator
Tower, and Diaphragm/Spring Components
Figure 6 - Installing Pressure Regulator Assembly
Mounting
Screws
Pressure
Regulator
Tower
Diaphragm/
Spring
Components
Mounting
Screws
Rubber Gasket
Identification Label
f i r e - p a r t s . c o m