background image

IHP.us.com

127195-01C

4

Figure 7 - Applying English and French Conversion Labels 
Over Existing Certifi cation Labels on Lighting Instruction Plate

French This Side

English This Side

VE N

TE

D G

A S F

IRE

PLA

C E H

E AT

E R

Conv

ersion

 Kit Model

PCD

M-36R

T

Type

 of G

as

Propane

/LP

Minim

um

 Inlet S

upply P

ressur

e

11.0" 

w.c.

For

 Purp

ose

 of In

put

 Adjustm

en

t

Man

ifold

 Pressur

"

0

.

0

1

e

 w.c.

O utput R

atin

g

Max. 

13,000 Btu

/h

Input

 Ratin

g

Max.

 20,000

 Btu/h

(0-450

0 Ft)

Min. 

13,000 Btu/h

Th

is A

ppliance is Eq

uipped

with an S

.I.T. N

ova M

odel

0.820.651

 Valve

C om

plies

 with

AN

S  Z21.88

-2000

C SA 

2.33-200

0

Vented

 G as

 Fire

place

Heater

116

635-

01

Previous M

ode

l #

___

___

___

__

__

C

US

Conversion Labeling and Placement

1.  Apply the English and French conversion labels over existing certifi -

cation labels 

(see 

Figure 7

)

. Existing certifi cation labels are located 

on the lighting instruction plate inside the gas valve compartment 
area. With permanent ink, print the previous model number on the 
label in the space provided

 (see 

Figure 8

).

2.  After fi lling in the data required on the conversion information label 

(see 

Figure 9

)

, affi x it to the fl oor of the appliance where it is easily 

seen when the lower louver access panel is removed.

Figure 9 - Conversion Information Label

CONVERSION INFORMATION LABEL

This appliance was converted on

___  - ___ - ___  to ______________ gas

with Kit No. _______________________

by

_____________________________

_____________________________

_____________________________

(name and address of organization making
this conversion), which accepts the
responsibility that this conversion has been
properly made.

106080-01

56060

Day      Month     Year

Lighting 
Instruction 
Plate

Figure 8 - Print Previous Model Number on
Conversion Labels

Figure 10 - Converting Pilot Orifi ce

VENTED GAS FIREPLACE

Conversion Kit Model
Type of Gas

Previous Model #

C

US

PILOT ORIFICE CONVERSION

1.  Remove the pilot hood assembly from barrel using a 7/16” open 

end wrench 

(see 

Figure 10

).

2.  Remove the pilot orifi ce from inside the barrel with tweezers or a 

pair of needle nose pliers.

3.  Replace pilot orifi ce with propane/LP orifi ce supplied with this kit. 

The number 14 is stamped on the sleeve for identifi cation. Insert 
the open end of the new pilot orifi ce into the barrel and thread the 
pilot hood back onto the barrel.

4.  Tighten the hood using the 7/16” open end wrench until the hood 

is fully seated and in-line with the bracket.

 

IMPORTANT

: Be careful not to bend or kink the aluminum tubing 

during conversion. Make sure the pilot hood and orifi ce are properly 
mated and aligned after fi nishing this conversion.

Pilot Hood

Pilot Orifice

Barrel Clip

Pilot Bracket

7/16" Hex 
Wrench

f i r e - p a r t s . c o m

Summary of Contents for PCBE-36

Page 1: ...ING This conversion kit shall be installed by a qualified service agency in accordance with the manufac turer s instructions and all applicable codes and requirements of the authority having jurisdiction If the information in these instructions is not followed exactly a fire explosion or production of carbon monoxide may result causing property damage personal injury or loss of life The qualified ...

Page 2: ...e installer and adhered to the appliance at the time of the conversion Contact your local gas supplier for deration requirements for your area CAUTION The gas supply shall be shut OFF prior to discon necting the electrical power before proceeding with the conversion ATTENTION Avant d effecteur la conversion coupez d abord l alimentationengaz ensuite coupezl alimentation electrique Figure 1 Removin...

Page 3: ...rench on fitting to prevent turning burner tube 9 Retighten flare fitting on flexible manifold tube with the 3 4 open end wrench and 7 8 back up wrench 10 Reattach pilot shield onto burner bracket with screw removed in step 1 3 8 Deep Socket Propane LP Gas Orifice Propane LP Gas Air Mixer Fitting 3 8 Flare Fitting Natural Gas Orifice Fitting Burner Bracket Flange Burner Tube 7 8 Back Up Wrench Pil...

Page 4: ...d Figure 9 Conversion Information Label CONVERSION INFORMATION LABEL This appliance was converted on ___ ___ ___ to ______________ gas with Kit No _______________________ by _____________________________ _____________________________ _____________________________ name and address of organization making this conversion which accepts the responsibility that this conversion has been properly made 106...

Page 5: ... appliance owner s manual WARNING Test all gas piping and connections for leaks after installation or servicing Correct leaks at once WARNING Never use an open flame to check for a leak Apply noncorrosive leak detection fluid to all joints Bubbles forming show a leak Correct all leaks at once Figure 11 Inspect for Proper Burner Flame Appearance No Blue Flame Center Soot at Flame Tip Dark Orange Fl...

Page 6: ...___________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ __________________________________________________...

Page 7: ...___________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ __________________________________________________...

Page 8: ...P reserves the right to make changes at any time without notice in design materials specifica tions prices and also to discontinue colors styles and products Consult your local distributor for fireplace code information 1508 Elm Hill Pike Suite 108 Nashville TN 37210 fire parts com ...

Reviews: