Instruction Manual

a. The fuses are blown

b. The circuit breaker has tripped

c. No electricity supply.

d. The motor protection has cut off the 
    electricity supply due to overload.

Cause

Remedy

Fault

e. The drop cable is defective.

f. Over-voltage has occurred.

1. The pump does not run.

2. The pump runs but gives
    no water.

a. The discharge valve is closed.

b. No water or too low water level in well.

c. Check valve is stuck in its closed position.

d. The suction strainer is closed.

e. The pump is defective.

a. The draw-down is larger than anticipated.

b. The valves in the discharge pipe are
    partly closed/blocked.

c. 

The discharge pipe is partly chocked by impurities.

3. The pump runs at 
    reduced capacity.

4. Frequent starts and stops.

e. The pump and the riser pipe are partly 
    chocked by impurities.

f. The pump is defective.

d. The non-return valve of the pump is blocked.

g. Hole in discharge pipe.

h. The riser pipe is defective.

i.Under-voltage has occurred. 

a. The differential of the pressure switch 
    between the start and the stop pressures
    is too small.

b. The water level electrodes or level 
    switches in the reservoir have not been
    installed correctly.

c. Non return valve is leaking, stuck half-open
    or damaged

d. The supply voltage is unstable.

e. The motor temperature is too high.

Replace the blown fuses.  If the new fuses 
too blow, check the electrical installation and 
the drop cable.

Reset the circuit breaker.

Contact the electricity provider.

Check for motor / pump blockage.

Repair/replace the pump’s cable.

Check the electricity supply.

Open the valve.

Allow water to get collected.

Pull the pump and clean or replace the valve.

Pull the pump and clean the strainer.

Repair or replace the pump.

Increase the installation depth of the pump.  
Throttle the pump or replace it with a smaller 
capacity model

Check and clean/replace the valves as necessary.

Clean/replace the discharge pipe.

Pull the pump and check/replace the valve.

Pull out the pump.  Check and clean or replace 
the pump, if necessary.  Clean the pipes.

Repair/replace the pump.

Check and repair the piping.

Replace the riser pipe

Check the electricity supply.

Increase the differential.  However, the stop 
pressure must not exceed the operating pressure 
of the pressure tank, and the start pressure 
should be high enough to ensure sufficient 
water supply.

Adjust the intervals of the electrodes/level 
switches to ensure suitable time between the 
cutting-in or cutting-out of the pump.  See 
installation and operating instructions for 
automatic devices used.  If the intervals between 
start/stop cannot be changed via the automatics, 
the pump capacity may be reduced by throttling 
the discharge valve.

Pull the pump and clean/replace the 
non-return valve.

Check the electrical supply.

Check the water temperature.