The borewell should fully be developed and flushed free of cutting and sand.
Ÿ
Determine the maximum depth of well and the draw down level at max pump capacity. Pump setting depth should be
atleast one meter below the max draw down level.
Ÿ
Ensure a minimum velocity of 0.2 m/s part of the motor for proper cooling.
Ÿ
The motor should be filled with pure drinking water free of any silt or suspended particles. Replace the water filling drain
plugs without fail.
Ÿ
The electrical connections should be carried out by a qualified electrician.
Ÿ
Earthing should be provided with the motor body.
Ÿ
Ensure correct size of cable and suitable electrical protection devices like MCB, cut-off relay, contactors, etc. are provided.
Ÿ
Relay should be set for full load current mentioned and single phasing, dry run protection should be used to avoid coil
burning on account of dry running and single phasing.
Ÿ
Check for free rotation of pump and motor before coupling.
Ÿ
Check for vertical play before and after coupling.
Ÿ
Ensure that only recommended size of piping is used and the pump should be gripped by two flats of pipe wrench.
Ÿ
The threaded joints of pipe must be well cut and fit together tightly to ensure they do not work loosely.
Ÿ
Ensure the motor cable is not damaged when pump is lowered into the well.
Ÿ
Ensure the pump is completely submerged in the liquid before starting.
Ÿ
Ensure the pump is not stopped till the water becomes clearer, free of impurities, otherwise pump parts and check valve
gets clogged. Operate pumpset for atleast five minutes daily to avoid pump jamming.
Ÿ
Ensure no oversize backup fuse wires are used. This will damage the motor winding in case of short circuiting.
Ÿ
Ensure the valve is throttled to avoid dry running in case of low discharge. Do not test the pumpset outside bore in dry
conditions as this damages seals and bearings.
Ÿ
Do not use pump to handle water containing solid/fibrous substances.
INSTALLATION AND OPERATING INSTRUCTIONS