3 – 25
ᵑ
MAINTENAN
C
E
1000HOURS
10.Fill the hydraulic oil tank with oil.
See Recommended Lubricant Table.
11.Loosen the air purge valve
j
on the pump
housing. When oil flow of air bubbles, tighten
the purge valve
j
.
12.Start and operate the engine at idling speed for
five minutes.
13.Operate the control levers to allow the hydraulic
oil to circulate through all hydraulic circuits.
14.Lower the bucket to the ground with the arm and
bucket cylinder fully retracted and stop the engine.
15.Maintain the oil level between
FULL
and
ADD
marks on the level gauge
k
.
16.Pressurize the hydraulic oil tank.
Raise the boom with the arm, boom and bucket
cylinder fully extended.
Remove the fill plug
c
and then install fill plug
again.
17.Lower the bucket on the ground and stop the
engine.
Hydraulic Oil Change Intervals for Breaker
Works.
Hydraulic oil should be changed in every 500
service hours.
CAUTION
Bucket position at the time of
checking the hydraulic oil level.
Bucket position at the time of
sealing off hydraulic tank.
Summary of Contents for 55N3
Page 1: ...SERIAL NUMBER WP003001 55N3 PUB 1 OPERATION MANUAL 0903 ENG ...
Page 2: ......
Page 42: ...1 36 ᵏ SAFETY This page left intentionally blank ...
Page 102: ...3 32 ᵑ MAINTENANCE This page left intentionally blank ...
Page 104: ...4 2 ᵒ TROUBLE SHOOTING This page left intentionally blank ...
Page 106: ...5 2 ᵓ HYDRAULIC SYSTEM DIAGRAM This page left intentionally blank ...