Do not attempt to disassemble this monitor.

Battery replacement should only be performed by a qualified iHealth technician. To do otherwise will void your warranty

and possibly damage your unit.

Cuff replacement should only be performed by a qualified iHealth technician. To do otherwise

will possibly damage your unit.

WARRANTY INFORMATION

The iHealth View Wireless Blood Pressure Wrist Monitor is warranted to be free from defects in materials and workmanship

within one year from the date of purchase when used in accordance with the provided instructions. The warranty extends only to

the end user. We will, at our option, repair or replace without charge the iHealth View Wireless Blood Pressure Wrist Monitor

covered by the warranty. Repair or replacement is our only responsibility and your only remedy under the warranty.

EXPLANATION OF SYMBOLS

Symbol for "TYPE BF APPLIED PARTS" (cuff only)

Symbol for "THE OPERATION GUIDE MUST BE READ"

The sign background color: blue The sign graphical symbol: white

Symbol for "ENVIRONMENT PROTECTION – Waste electrical products should not be

disposed of with household waste. Please recycle where facilities exist. Check with your

local authority or retailer for recycling advice".

Symbol for "KEEP DRY"

Symbol for "WARNING"

Symbol for "MANUFACTURER"

Symbol for "SERIAL NUMBER"

Symbol for "EUROPEAN REPRESENTATIVE"

Symbol for "COMPILES WITH MDD93/42/EEC REQUIREMENTS"

iHealth is a trademark of iHealth Lab Inc.

"Made for iPod", "Made for iPhone", and "Made for iPad" mean that an electronic accessory has been designed to connect

specifically to iPod, iPhone, or iPad, respectively, and has been certified by the developer to meet Apple performance standards.

Apple is not responsible for the operation of this device or its compliance with safety and regulatory standards. Please note that

the use of this accessory with iPod, iPhone, or iPad may affect wireless performance. iPad, iPhone, and iPod touch are

trademarks of Apple Inc., registered in the U.S. and other countries.

CONTACT AND CUSTOMER SERVICE

Manufactured for iHealth Lab Inc.

719N . Shoreline Blvd.,Mountain View, CA 94043, USA

Tel:+1-855-816-7705

www.ihealthlabs.com

Summary of Contents for View

Page 1: ...T UP REQUIREMENTS 2 SET UP PROCEDURES 3 MEASUREMENT PROCEDURES 3 SPECIFICATIONS 4 GENERAL SAFETY AND PRECAUTIONS 5 BATTERY HANDLING AND USAGE 6 TROUBLESHOOTING 6 CARE AND MAINTENANCE 7 WARRANTY INFORM...

Page 2: ...gned to measure the systolic and diastolic blood pressures and pulse rate of an adult individual by using a technique in which an inflatable cuff is wrapped around the wrist The measurement range of t...

Page 3: ...sure measurements 1 Sit comfortably with your feet flat on the floor without crossing your legs Stay still during measurement Do not move your wrist body or the monitor 2 Place your hand palm side up...

Page 4: ...ar and then select it to pair This may take up to 30 seconds and your monitor s Bluetooth indicator will light up when a connection has been established Launch the iHealth MyVitals app to sync with yo...

Page 5: ...ethod within the limits prescribed by the American National Standard Electronic or Automated Sphygmomanometer This device is also clinically validated according to the 2010 Protocol of the European So...

Page 6: ...ery when the battery is less than 25 charged Overcharging the battery may reduce its lifetime When in charging mode the charging status will be displayed on the LED screen See the table below for deta...

Page 7: ...gnetic interference Press the START STOP button and hold for about 10 seconds to reset the device CARE AND MAINTENANCE 1 If this monitor is stored near freezing temperatures allow it to return to room...

Page 8: ...lue The sign graphical symbol white Symbol for ENVIRONMENT PROTECTION Waste electrical products should not be disposed of with household waste Please recycle where facilities exist Check with your loc...

Page 9: ...easures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receive...

Page 10: ...c discharge ESD IEC 61000 4 2 6 kV contact 8 kV air 6 kV contact 8 kV air Floors should be wood concrete or ceramic tile If floors are covered with synthetic material the relative humidity should be a...

Page 11: ...all situations Electromagnetic propagation is affected by absorption and reflection from structures objects and people a Field strengths from fixed transmitters such as base stations for radio cellul...

Page 12: ...rs m can be determined using the equation applicable to the frequency of the transmitter where P is the maximum output power rating of the transmitter in watts W according to the transmitter manufactu...

Reviews: