Manual i.Sense EC.P- V 1.1 

 

3.2  Technical data 

Mechanical specifications DIN rail module 

D x W x H in millimetres incl. connector and fastening elements 

17,5 x 99 x114,5 mm 

weight in grams 

approx. 120 g 

mounting/ installation 

TS35 support rail in earthed switch cabinet 

colour 

Light grey, like RAL 7035 

material 

Polyamid 

flamability 

UL 94 V0 

 

Mechanical specifications load cell 616 

D x W x H in millimetres incl. connector and fastening elements 

114,10 x 26 x 80 mm 

mounting/ installation 

Screw lugs at Obertrunn of e-chain® 

material 

Stainless steel 

Tightening torque 

T30 

M6 

10 Nm 

T45 

M8 

23 Nm 

T50 

M10 

35 Nm 

T55 

M12 

75 Nm 

 

 
Mechanical specifications load cell 620 

D x W x H in millimetres incl. connector and fastening elements 

88 x 32 x 90 mm 

mounting/ installation 

Screw lugs at Obertrunn of e-chain® 

material 

Stainless steel 

Tightening torque 

T30 

M6 

10 Nm 

T45 

M8 

23 Nm 

T50 

M10 

35 Nm 

T55 

M12 

75 Nm 

 

 
Electrical specifications

 

Risk of destruction 

An operating voltage that exceeds the voltage specified in the technical data will destroy the i.Sense EC.P. Select an 
operating voltage that is within the voltage range specified in the technical data.  
Note any interference and voltages induced by other consumers and/or motors and plan corresponding safety reserves 
and  countermeasures.  Ensure  that  your  power  supply  is  feedback  protected  if  load  and  logic  voltage  come  from  the 
same power supply or the same transformer 

C

A

U

TI

ON

!

 

 

Power supply 

24 V DC 

Nominal current 

Max. 0,16 A 

Potential free contact 

24 V DC 0,3A max. 

Storage  

SD-card (micro SDHC-card Class 10) min 8GB 

250 CSV files (1x CSV ca. 8h), circular buffer 

UART interface 

5V & 3,3V compatible, 19200 baud 

Accuracy 

± 

1% 

Connectable conductor cross-section 

0,14 … 2,5 mm

2

 

 

 

 

Summary of Contents for i.Sense EC.P

Page 1: ...1 14 Manual i Sense EC P V 1 1 igus smart plastics i Sense EC P Manual V1 1 Operation instruction Manual german version...

Page 2: ...lation 7 4 1 Mechanical installation 7 4 2 Electrical installation 7 4 2 1 Power supply selection 7 4 2 2 Connector assignment and sensor connection 8 5 Sensor installation 10 5 1 Configuration 10 5 1...

Page 3: ...dicate possible hazardous situations Disregarding the notice may lead to an accident or damage to property CAUTION Safety instructions marked with NOTE indicate a potential hazardous situation Disrega...

Page 4: ...alified personnel igus GmbH accepts no liability whatsoever for personal injury or damage to property resulting from incorrect use or from unauthorized technical modifications to the i Sense EC P The...

Page 5: ...ors RC modules Reduce mutual interference coupling Wiring Keep cables as short as possible Avoid capacitive and inductive interference coupling Do not lay sensor cables and signal cables together with...

Page 6: ...ting installation Screw lugs at Obertrunn of e chain material Stainless steel Tightening torque T30 M6 10 Nm T45 M8 23 Nm T50 M10 35 Nm T55 M12 75 Nm Electrical specifications Risk of destruction An o...

Page 7: ...itching off wait at least five minutes until the capacitors are discharged Check that there is no voltage before working in the system Occurrence of electric arcs in case of improperly installed elect...

Page 8: ...r assignment and sensor connection Wires with cross sections of 0 15 2 5 mm2 connectable with screws Recommended to use terminal blocks for connecting sensorics structured wiring is given easier Conne...

Page 9: ...load cell model 616 1t Clamp Name Colour 9 Excitation Sense Green blue 10 Excitation Sense black brown 11 Signal white 12 Signal red 16 Shield Shield Vishay load cell model 620 2t Clamp Name Colour 9...

Page 10: ...ishing the configuration the RESET button must be pushed for five seconds while the device turns on After that the limits have been set from values txt NOTE EC P 03 load cell capacity one force limit...

Page 11: ...of 250 files can be stored before the circular buffer begins again at file that file will be overwritten 6 1 String structure The sensor messages are given in that form IS EC P 03 IS EC P 07 If force...

Page 12: ...e with the responsible igus branch to avoid invalidating your guarantee Any other procedure voids the guarantee NOTE Date and time must be reset after changing the battery NOTE high Red Force Error Th...

Page 13: ...0 000 MAT01722742 Igus Vishay load cell 620 2t 5 20 000 MAT01722743 Igus Beam for mounting carrying run 1 customer Chainflex cable with assembled M12 connector 1 Customer s specification Igus screws s...

Page 14: ...ttps www igus de info zustandsueberwachung ec p Download of manuals FW updates and certificates Website smart Plastics https www igus de info vorausschauende wartung smart plastics Possibility to orde...

Page 15: ......

Page 16: ......

Page 17: ......

Page 18: ......

Page 19: ......

Page 20: ......

Page 21: ......

Page 22: ......

Page 23: ......

Page 24: ......

Page 25: ......

Page 26: ......

Page 27: ......

Page 28: ......

Page 29: ......

Page 30: ......

Page 31: ......

Page 32: ......

Page 33: ......

Page 34: ...fachen Integrationsm glichkeit werden diese S f rmigen W gezellen auch sehr h ufig in der physikalischen Einheit Newton N kalibriert und als Kraftaufnehmer eingesetzt Zu den typische Applikationen geh...

Page 35: ...Schwarz Wei Elektrischer Anschluss 6 Leiter Kabel abgeschirmt 3 m M12x1 75 26 18 62 10 80 52 30 flexibel Max Anzahl der Teilungswerte Mindestanwendungsbereich Mindestteilungswert v E Y min max Zusamm...

Page 36: ...en typische Applikationen geh ren dann Kraftmessungen in Material Pr pfmaschinen die berwachung von Seilzugspannungen an Fahrst hlen Lastkr nen Br cken Zelten sowie Drehmomentmessungen ber Hebelarme a...

Page 37: ...x 2 0 5 000 kg Messbereiche 500 1 000 2 000 kg Messbereich 5 000 kg Elektrischer Anschluss 6 Leiter Kabel abgeschirmt 5 m Max Anzahl der Teilungswerte Mindestanwendungsbereich Mindestteilungswert v E...