background image

Channel

Value

Function

118…125

Cold white, 7200 K

126…127

Colour change halted

128…191

Colour change effect, increasing speed

192…255

Colour transition effect, increasing speed

9

Rainbow effect

0…5

Effect off

6…21

Rainbow effect 1

22…37

Rainbow effect 2

38…53

Rainbow effect 3

54…69

Rainbow effect 4

70…85

Rainbow effect 5

86…101

Rainbow effect 6

102…117

Rainbow effect 7

Operating

 

60

Co6 V2 LED Flood IP65 270W RGBW

LED floodlight

Summary of Contents for 477575

Page 1: ...Co6 V2 LED Flood IP65 270W RGBW LED floodlight User manual...

Page 2: ...Musikhaus Thomann Thomann GmbH Hans Thomann Stra e 1 96138 Burgebrach Germany Telephone 49 0 9546 9223 0 E mail info thomann de Internet www thomann de 22 04 2020 ID 477575...

Page 3: ...7 2 Safety instructions 10 3 Features 16 4 Installation 18 5 Starting up 24 6 Connections and controls 27 7 Operating 31 7 1 Starting the device 31 7 2 Main menu 32 7 2 1 Operating mode DMX 45 7 2 2 O...

Page 4: ...mode 54 7 8 Functions in 6 channel DMX mode 54 7 9 Functions in 12 channel DMX mode 56 7 10 Functions in 14 channel DMX mode 57 7 11 Functions in 26 channel DMX mode 64 8 Technical specifications 72 9...

Page 5: ...o all persons using this device If you sell the device to another user be sure that they also receive this manual Our products and user manuals are subject to a process of continuous development We th...

Page 6: ...search function in the electronic version to find the topics of interest for you quickly Online guides Our online guides provide detailed information on technical basics and terms Personal consultatio...

Page 7: ...xamples VOLUME control Mono button Texts and values displayed on the device are marked by quotation marks and italics Examples 24ch OFF 1 3 Symbols and signal words In this section you will find an ov...

Page 8: ...indicates a pos sible dangerous situation that can result in death or serious injury if it is not avoided NOTICE This combination of symbol and signal word indicates a pos sible dangerous situation t...

Page 9: ...Warning signs Type of danger Warning suspended load Warning danger zone General information Co6 V2 LED Flood IP65 270W RGBW 9 LED floodlight...

Page 10: ...mage No liability will be assumed for damages resulting from improper use This device may be used only by persons with sufficient physical sensorial and intellectual abilities and having corresponding...

Page 11: ...oke Never let children unattended use electrical devices DANGER Hazardous voltage The wiring as well as all maintenance and repair work on the electrical installa tion of the device must only be perfo...

Page 12: ...nt Never remove any covers There are no user serviceable parts inside Do not use the device if covers protectors or optical components are missing or damaged WARNING Eye damage caused by high light in...

Page 13: ...installation complies with the standards and rules that apply in your country Always secure the device with a secondary safety attachment such as a safety cable or a safety chain Secure the barn door...

Page 14: ...age AC outlet matches the voltage rating of the device and that the AC outlet is protected by a residual current circuit breaker Failure to do so could result in damage to the device and possibly inju...

Page 15: ...react with the coating of your parquet linoleum laminate or PVC floor and after some time cause permanent dark stains In case of doubt do not put the rubber feet directly on the floor but use felt pad...

Page 16: ...olour gradients n Selectable dimmer curves n Selectable repetition frequency up to 25 kHz n Master Slave mode n Robust aluminium housing n Due to protection class IP65 operation is also possible outdo...

Page 17: ...ode digit That is why this equipment can also be used outdoors Event technology equipment is generally only designed for temporary use however event lighting and not for permanent use outdoors The spe...

Page 18: ...ng material suitable for transport or storage respectively DANGER Hazardous voltage The wiring as well as all maintenance and repair work on the electrical installa tion of the device must only be per...

Page 19: ...as a safety cable or a safety chain When using the diffusion filter the barndoor must be mounted above it At this all four locking pins of the barndoor must be fully engaged Secure the barn door with...

Page 20: ...tilation The ambient temperature must always be below 40 C 104 F NOTICE Use of stands When mounting the device onto a stand ensure that the stand is in a safe and stable position and that the weight o...

Page 21: ...error free operation make use of dedicated DMX cables and do not use ordi nary microphone cables Never connect the DMX input or output to audio devices such as mixers or ampli fiers Installation Co6 V...

Page 22: ...bottom case as shown in the following figure You can install the unit in hanging or standing position When in use the device must always be attached to a solid surface or an approved truss Always wor...

Page 23: ...1 Openings for safety cable 2 Quick lock openings for omega bracket Installation Co6 V2 LED Flood IP65 270W RGBW 23 LED floodlight...

Page 24: ...connections while the device is off Use the shortest possible high quality cables for all connections Take care when running the cables to prevent tripping hazards Starting up 24 Co6 V2 LED Flood IP65...

Page 25: ...nnect the output of the first DMX device to the input of the second one and so on to form a daisy chain Always ensure that the output of the last DMX device in the daisy chain is terminated with a res...

Page 26: ...h programming Connect the DMX output of the master unit to the DMX input of the first slave unit Then connect the DMX output of the first slave unit to the DMX input of the second slave unit and so on...

Page 27: ...6 Connections and controls Connections and controls Co6 V2 LED Flood IP65 270W RGBW 27 LED floodlight...

Page 28: ...MODE Activates the main menu and toggles between menu items Closes an opened submenu UP Navigates upwards in a menu list Increases the displayed value by one DOWN Navigates downwards in a menu list De...

Page 29: ...Rear panel Connections and controls Co6 V2 LED Flood IP65 270W RGBW 29 LED floodlight...

Page 30: ...7 POWER OUT Lockable chassis socket Power Twist TR1 IP65 for the power supply of another device 8 DMX OUT DMX output designed as 3 pin XLR panel socket IP65 9 DMX IN DMX input designed as 3 pin XLR p...

Page 31: ...s the display indicates that a reset is in progress The device is then ready for use The display shows the operating mode that was selected when the unit was last powered off If the DMX mode is set wi...

Page 32: ...r about 30 seconds the main menu will be reactivated automati cally All previously made settings are retained even when you disconnect the device from the power grid To restart with default values use...

Page 33: ...a DMX mode DMX 2Ch 2 channel DMX mode DMX 3Ch1 3 channel DMX mode 1 DMX 3Ch2 3 channel DMX mode 2 DMX 4Ch 4 channel DMX mode DMX 6Ch 6 channel DMX mode DMX 12Ch 12 channel DMX mode DMX 14Ch 14 channe...

Page 34: ...Jump effect Static Dimmer 0 255 Setting the overall brightness Strobe Strobe effect 0 5 Open strobe 6 10 Closed strobe 11 33 Random Pulse effect with increasing speed 34 56 Random Ramp up effect with...

Page 35: ...eed 103 127 Strobe break effect with decreasing duration of interruptions 128 250 Strobe effect with increasing speed 251 255 Open strobe Red 0 255 Intensity red 0 to 100 Green 0 255 Intensity green 0...

Page 36: ...Rainbow Effect Rainbow effect 0 5 Effect off 6 21 Rainbow effect 1 22 37 Rainbow effect 2 38 53 Rainbow effect 3 54 69 Rainbow effect 4 70 85 Rainbow effect 5 86 101 Rainbow effect 6 102 117 Rainbow...

Page 37: ...10 166 181 Rainbow effect 11 182 197 Rainbow effect 12 198 213 Rainbow effect 13 214 229 Rainbow effect 14 230 255 Rainbow effect 15 Auto Automatic show 0 5 No automatic show 6 30 Automatic show 1 31...

Page 38: ...atic show 6 156 180 Automatic show 7 181 205 Automatic show 8 206 230 Automatic show 9 231 255 Automatic show 10 Auto speed 0 255 Running speed auto matic show increasing Auto Fade 0 255 Fade speed fo...

Page 39: ...g Amber Amber Yellow Warm Yellowish amber coloured Yellow Yellow Green Green Turquoise Turquoise Cyan Cyan Blue Blue Lavender Lavender Mauve Mauve Magenta Magenta Pink Pink Warm White Warm white Opera...

Page 40: ...version ON On The display is rotated by 180 OFF Off Normal display Display Automatic display shutdown when not in use ON Disabled OFF Enabled DMX Fail Device behaviour on DMX signal failure Hold Retai...

Page 41: ...D Dimmer characteristic LED 3 s delay Halogen Dimmer characteristic Halogen 5 s delay LED Frequency 800 Hz Refresh rate of the LEDs 800 Hz 1200 Hz Refresh rate of the LEDs 1200 Hz 2000 Hz Refresh rate...

Page 42: ...ue proportion White 0 255 White proportion Fan Set Fan speed Regular If the temperature exceeds the threshold the fan speed will increase Silent If the temperature exceeds the threshold the light outp...

Page 43: ...ss DMX con nection is not getting reset Yes The wireless DMX con nection is getting reset Test Automatic self test OFF Turned off ON On Factory Reset Reset to factory defaults OFF Turned off ON Starti...

Page 44: ...stem Info Firmware Show firmware version of the device Temperature LED Temp Show device temperature Temp Unit Unit selection for device temperature Fahrenheit Celsius Time info Operating hours display...

Page 45: ...device is controlled via W DMX the LED W DMX LED flashes on its front panel The dis play shows the signal strength in the top row no signal weak signal medium signal strong signal 7 2 2 Operating mode...

Page 46: ...ng Mode AUTO Fading Automatic Fade effect n Operating Mode AUTO Jumping Automatic Jump effect n Operating Mode STATIC Freely mixable colour with optional rainbow and stroboscopic effect or automatic s...

Page 47: ...7 3 Menu overview Operating Co6 V2 LED Flood IP65 270W RGBW 47 LED floodlight...

Page 48: ...Operating 48 Co6 V2 LED Flood IP65 270W RGBW LED floodlight...

Page 49: ...Value Function 1 0 255 Dimmer 0 to 100 2 Colour macro 0 5 Blackout 6 13 Red 14 21 Amber 22 29 Yellowish amber coloured 30 37 Yellow 38 45 Green 46 53 Turquoise 54 61 Cyan 62 69 Blue Operating Co6 V2...

Page 50: ...101 Pink 102 109 Warm white 3200 K 110 117 White 5600 K 118 125 Cold white 7200 K 126 127 Colour change halted 128 191 Colour change effect increasing speed 192 255 Colour transition effect increasing...

Page 51: ...er 0 to 100 2 Stroboscope functions 0 5 Open strobe 6 10 Closed strobe 11 250 Strobe effect with increasing speed 251 255 Open strobe 3 Colour macro 0 5 Blackout 6 13 Red 14 21 Amber 22 29 Yellowish a...

Page 52: ...53 Turquoise 54 61 Cyan 62 69 Blue 70 77 Lavender 78 85 Mauve 86 93 Magenta 94 101 Pink 102 109 Warm white 3200 K 110 117 White 5600 K 118 125 Cold white 7200 K 126 127 Colour change halted Operating...

Page 53: ...192 255 Colour transition effect increasing speed 7 6 Functions in 3 channel DMX mode 2 Channel Value Function 1 0 255 Intensity red 0 to 100 2 0 255 Intensity green 0 to 100 3 0 255 Intensity blue 0...

Page 54: ...100 2 0 255 Intensity green 0 to 100 3 0 255 Intensity blue 0 to 100 4 0 255 Intensity white 0 to 100 7 8 Functions in 6 channel DMX mode Channel Value Function 1 0 255 Dimmer 0 to 100 2 Stroboscope...

Page 55: ...0 Strobe effect with increasing speed 251 255 Open strobe 3 0 255 Intensity red 0 to 100 4 0 255 Intensity green 0 to 100 5 0 255 Intensity blue 0 to 100 6 0 255 Intensity white 0 to 100 Operating Co6...

Page 56: ...100 LED row 1 4 0 255 Intensity white 0 to 100 LED row 1 5 0 255 Intensity red 0 to 100 LED row 2 6 0 255 Intensity green 0 to 100 LED row 2 7 0 255 Intensity blue 0 to 100 LED row 2 8 0 255 Intensit...

Page 57: ...row 3 7 10 Functions in 14 channel DMX mode Channel Value Function 1 0 255 Dimmer 0 to 100 2 0 255 Fine adjustment of the dimmer 0 100 3 Stroboscope functions 0 5 Open strobe 6 10 Closed strobe 11 33...

Page 58: ...g speed 103 127 Strobe break effect with decreasing duration of interruptions 128 250 Strobe effect with increasing speed 251 255 Open strobe 4 0 255 Intensity red 0 to 100 5 0 255 Intensity green 0 t...

Page 59: ...lowish amber coloured 30 37 Yellow 38 45 Green 46 53 Turquoise 54 61 Cyan 62 69 Blue 70 77 Lavender 78 85 Mauve 86 93 Magenta 94 101 Pink 102 109 Warm white 3200 K 110 117 White 5600 K Operating Co6 V...

Page 60: ...ing speed 192 255 Colour transition effect increasing speed 9 Rainbow effect 0 5 Effect off 6 21 Rainbow effect 1 22 37 Rainbow effect 2 38 53 Rainbow effect 3 54 69 Rainbow effect 4 70 85 Rainbow eff...

Page 61: ...166 181 Rainbow effect 11 182 197 Rainbow effect 12 198 213 Rainbow effect 13 214 229 Rainbow effect 14 230 255 Rainbow effect 15 10 Automatic show 0 5 No automatic show 6 30 Automatic show 1 31 55 A...

Page 62: ...180 Automatic show 7 181 205 Automatic show 8 206 230 Automatic show 9 231 255 Automatic show 10 11 0 255 Running speed automatic show increasing 12 0 255 Automatic Fade effect 13 Dimmer curve 0 5 No...

Page 63: ...corresponding DMX value is held for five seconds 0 5 No function 6 63 Dimmer characteristic LED 3 s delay 64 127 Dimmer characteristic Halogen 5 s delay 128 191 Fan speed setting Silent activated 3 s...

Page 64: ...strobe 11 33 Random Pulse effect with increasing speed 34 56 Random Ramp up effect with increasing speed 57 79 Random Ramp down effect with increasing speed 80 102 Random strobe effect with increasing...

Page 65: ...0 255 Intensity green 0 to 100 6 0 255 Intensity blue 0 to 100 7 0 255 Intensity white 0 to 100 8 Colour macro 0 5 Blackout 6 13 Red 14 21 Amber 22 29 Yellowish amber coloured 30 37 Yellow 38 45 Green...

Page 66: ...94 101 Pink 102 109 Warm white 3200 K 110 117 White 5600 K 118 125 Cold white 7200 K 126 127 Colour change halted 128 191 Colour change effect increasing speed 192 255 Colour transition effect increas...

Page 67: ...ow effect 3 54 69 Rainbow effect 4 70 85 Rainbow effect 5 86 101 Rainbow effect 6 102 117 Rainbow effect 7 118 133 Rainbow effect 8 134 149 Rainbow effect 9 150 165 Rainbow effect 10 166 181 Rainbow e...

Page 68: ...t 15 10 Automatic show 0 5 No automatic show 6 30 Automatic show 1 31 55 Automatic show 2 56 80 Automatic show 3 81 105 Automatic show 4 106 130 Automatic show 5 131 155 Automatic show 6 156 180 Autom...

Page 69: ...c Fade effect 13 Dimmer curve 0 5 No function 6 63 Linear 64 127 Exponential 128 191 Logarithmic 192 255 S shaped 14 Special functions Settings are enabled or retained if the corresponding DMX value i...

Page 70: ...ity green 0 to 100 LED row 1 17 0 255 Intensity blue 0 to 100 LED row 1 18 0 255 Intensity white 0 to 100 LED row 1 19 0 255 Intensity red 0 to 100 LED row 2 20 0 255 Intensity green 0 to 100 LED row...

Page 71: ...Channel Value Function 25 0 255 Intensity blue 0 to 100 LED row 3 26 0 255 Intensity white 0 to 100 LED row 3 Operating Co6 V2 LED Flood IP65 270W RGBW 71 LED floodlight...

Page 72: ...the unit Number of DMX channels 2 3 4 6 12 14 or 26 Input connections Voltage supply Power Twist IP65 DMX control XLR chassis socket 3 pin IP65 version Output connections Voltage supply Power Twist IP...

Page 73: ...ting options hanging standing Omega bracket Dimensions W H D 395 mm 265 mm 145 mm panel horizontal Weight 8 2 kg Ambient conditions Temperature range 20 C 40 C Relative humidity 50 non condensing Tech...

Page 74: ...ght Colour mixture RGBW LED type x in 1 Floor housing Yes Fanless No Remote control Not possible Wireless DMX Yes Housing colour black Further information Technical specifications 74 Co6 V2 LED Flood...

Page 75: ...sult of an incorrect connection may be a destroyed DMX controller a short circuit or just a not working light show The unit offers a 3 pin XLR socket for DMX output and a 3 pin XLR plug for DMX input...

Page 76: ...eshooting In the following we list a few common problems that may occur during operation We give you some suggestions for easy troubleshooting Troubleshooting 76 Co6 V2 LED Flood IP65 270W RGBW LED fl...

Page 77: ...ite Balance menu to 255 You can then fine tune the colour rendering No response to the DMX controller 1 Check the DMX connectors and cables for proper connection 2 Try using another DMX controller 3 C...

Page 78: ...ressing the Link button on the transmitter The device does not respond or only with a delay to the W DMX signal Check the transmission mode of the W DMX transmitter Test the connection with the G5 G4S...

Page 79: ...f cleaning depends on the operating environment wet smoky or particularly dirty surroundings can cause more accumulation of dirt on the optics of the device n Clean with a soft cloth using our lamp an...

Page 80: ...ings on the packaging This product is subject to the European Waste Electrical and Electronic Equipment Directive WEEE in its currently valid version Do not dispose with your normal household waste Di...

Page 81: ...Notes Co6 V2 LED Flood IP65 270W RGBW 81 LED floodlight...

Page 82: ...Notes 82 Co6 V2 LED Flood IP65 270W RGBW LED floodlight...

Page 83: ......

Page 84: ...Musikhaus Thomann Hans Thomann Stra e 1 96138 Burgebrach Germany www thomann de...

Reviews: