background image

631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
www.lightolier.com © 2010 Philips Group •

Job Information 

Type:

Job Name: 
Cat. No.: 

Lamp(s): 
Notes:

Lighting Systems 

CTS3-13 

Page 1 of 2 

Central Trough System 1-Light T5 Per Section

G1107

Ordering Information

  Family 

Mounting 

Shielding 

Configuration 

Output 

Length (nom.) 

Housing 

Voltage 

Option

 

CT3

 

G

 

L

 

A

 

 

 

 

 

CT3

 

G

 = Grid Mount 

= Flush 

A

 = 1 Lamp

1

 

H

 = High  

2

 = 2-foot 

U

 = Indiv. Unit

2

 

1

 = 120V 

E

 = EM Pack

4

   

Lens 

  

Output 

4

 = 4-foot 

S

 = Starter 

2

 = 277V 

T

 = Tandem Switch

   

 

 

S

 = Standard 

8

 = 8-foot 

J

 = Joiner 

 

4

 = 4 Through Wires

   

 

  

 

 T

 = Telescoping

3

  

5

 = 5 Through Wires

   

 

  

 

    

D

 = Dimming

5

3

5

6

7

1

2

4

1

/

8

" (13.02cm)

3" (7.62cm)

3

/

4

"

(9.53cm)

Complete ordering instructions below.

Features

1. Housing: 

20 gauge pre-painted steel

2. Bulkhead: 

18 gauge galvanized steel

3. Reflector:

 semi-specular aluminum

4. Trim:

 none visible, fixture drops into grid system by others

5. Ballast: 

program start electronic

6. Lamp: 

T5 or T5 HO fluorescent

7. Lens:

 extruded frosted acrylic

  Optional Extended Continuous Length Lens shown on page 2.

Mounting

Housing is suspended by hanger wires by others. Compatible with standard and slot 
T grid systems. Optional factory provided Quick-Draw Installation System shown on 
page 2.

Electrical

Electronic Ballast:

 Programmed start, 3 conductor, 12 gauge wire.  

Color-coded quick connectors allow easy connection for modular fixtures.  T5HO 
lamps are dimmed with Advance Mark 10.  T5 standard output lamps are dimmed 
with ULT Super Dim.  Use compatible dimmers and feed wires.  Factory installed 
ballast disconnect allows the ballast to be disconnected from and reconnected to 
incoming power under load without turning the entire circuit off.

Emergency Battery Pack:

 450 Lumens @ 90 minimum.

Labels

UL, cUL and IBEW

Ordering Instructions

Individual Fixtures:

1.

  Order number of INDIVIDUAL UNITS required.

Continuous Rows:

1.

  Determine run length

2.

  Order one Starter fixture

3.

  Order one Telescoping fixture*

4.

  Order remainder of Joiner fixtures

* For best one-lamp effect, use Telescoping fixture at longest length possible.
Continuous runs only - Prior to installing CTS3 in a grid ceiling, the installing 
contractor must ensure that the fixture will set into two main runners, spaced 4" 
(10.16cm) on center.  No grid cross members are required except at the beginning 
and end of the run.

1

  Lamp is mounted diagonally and extends into adjacent fixture by 2-1/2" (6.35cm) in Starter, Joiner and Telescoping fixtures

2

  8-foot Individual Unit not available in Grid Mount

3

  Telescoping fixture ships 85-3/8" (216.85cm), adjustable down to 49-3/8" (125.41cm)

4

  EM pack not available in 2-foot or Telescoping fixtures

5

  Advance Mark X dimming not available in 2' fixtures