background image

Quick Start 
Guide

 

 

 

 
 
 

 

 

Hardware Specifications

 

 

 

Chassis

 

Size (L x W x H:) 

121 x 121  x 30.5 mm (4.76 x 4.76 x 1.2 inches) 

Weight 

196 g (0.43 lb) 

Temperature 

Operating: -20 °C to 65 °C  

Humidity 

Operating: 10% to 90% (non-condensing) 

 

 

Network Interfaces

 

Ports 

WAN/PoE 

RJ-45 Port: 1000BASE-T, passive PoE 

LAN1 

RJ-45 Port: 100BASE-TX 

LAN2 

RJ-45 Port: 100BASE-TX 

2.4 GHz Radio 

IEEE 802.11b/g/n 

5 GHz Radio 

IEEE 802.11a/n/ac 

Radio Frequencies 

2412 ~ 2462 MHz 

5180 ~ 5240 MHz 
5745 ~ 5825 MHz 

 

 

Power Supply

 

AC Power Adapter 

Input: 100-240 VAC, 50-60 Hz, auto-sensing 
Output: 12, 24 VDC, 1.5 A maximum @ 12 VDC 

Passive PoE Input Power 

24 VDC, 0.7 A maximum @ 24 VDC 

 

 

 

Regulatory Compliances

 

Radio 

EN 300 328 V1.8.1:2012 
EN 301 893 V1.7.1:2012 
EN 301 489-1 V1.9.2 (2011-09) 
EN 301 489-7 V1.3.1:2005 
FCC Part 15C 15.247/15.207  
FCC Part 15E 15.407  

Emissions 

EN 55022 2010+AC:2011 
EN 61000-3-2 2006+A1:2009+A2:2009 

FCC Class B Part 15 

Immunity 

EN 55024 : 2010 
EN 61000-4-2 : 2009 

 

 

 
 
 
 
 
 

 

–  8  –

 

Spark AC750 

E052015-CS  150200001184A 

R01 

 

 

 

 

Item 

Specification 

Summary of Contents for Spark IR-AC750

Page 1: ...r by the universal power supply included in the package through an Ethernet cable connection from a Power over Ethernet PoE injector or from a 802 3af compliant PoE switch The Cloud Enabled Enterprise...

Page 2: ...fessional contractor knowledgeable in local radio regulations prior to equipment installation 1 Unpack the AP Unpack the AP and check the package contents Cloud Enabled Enterprise Access Point Spark A...

Page 3: ...r the wall plugs and screws Drill four holes for the wall plugs and then insert the plugs and tap them flush with the wall surface Align the mounting plate with the four holes and then use the four sc...

Page 4: ...t sizes of suspended ceiling T bars The position illustrated below is for 15 mm bars Use the position at a 90 degrees angle for 24 5 mm bars Suspended Ceiling Mounting Press the retention clips of the...

Page 5: ...the AC DC power adapter provided in the package by a PoE power injector Spark AC750 Powering the AP with the AC DC Power Adapter Connect the cable from the power adapter to the DC power jack on the AP...

Page 6: ...on of all the unit s features If cloud managing the AP go directly to Manage the AP with the IgniteNet Cloud Controller on page 7 Toaccess the web interface connect a PC directly to the AP s LAN1 or L...

Page 7: ...t Cloud Controller Go to cloud ignitenet com to register your AP Log in and select Devices from the menu Click Add Device and enter the AP serial number and MAC address to register the AP with your cl...

Page 8: ...ac Radio Frequencies 2412 2462 MHz 5180 5240 MHz 5745 5825 MHz Power Supply AC Power Adapter Input 100 240 VAC 50 60 Hz auto sensing Output 12 24 VDC 1 5 A maximum 12 VDC Passive PoE Input Power 24 V...

Page 9: ...ns may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference...

Page 10: ...ted rule knowledge The general user shall not attempt to install or change the setting 2 Installation location The product shall be installed at a location where the radiating antenna can be kept 20cm...

Reviews: