![IGM 142-BR500 Operating Instructions Manual Download Page 10](http://html1.mh-extra.com/html/igm/142-br500/142-br500_operating-instructions-manual_622131010.webp)
Operating instructions EN
The tape is slipping on
the infeed roller
Dust or debris on the infeed roller Clean the infeed roller
The feed won‘t turn on
The glue isn‘t melted enough,
the operating temperature hasn‘t
been reached so far
The motor can be turned on after reaching 12 °C
to ensure proper temperature for work.
Overheating
Malfunctioning temperature
control
Let a qualified electrician replace the
tempereature detector
10. PROTECTION OF THE ENVIRONMENT
Protect the environment.
Your machine contains materials that can be recycled.
Please, let specialized institutions handle the machine.
11.ACCESSORIES (spare parts)
iGM Tape Holder for Edgebander DR500-BR300
142-BC25
IGM Battery Set for Edgebander DR500
142-LB24
IGM PD80 Edgeband Trimmer
142-PD80
IGM End Trimmer for Shaped and Straight Panels
M951
IGM Fachmann Edge Banding Hand Trimmer
M950-00001
IGM Worktable for Edgebander and Trimmer for
DR500-BR300
142-ST95A
IGM Straightline Edgebanding and Trimming Kit for
Worktable ST95A
142-ST97
Glue Technomelt KS224 for IGM Manual Edgebanders -
1kg pack
M967-1
Glue Technomelt KS224 for IGM Manual Edgebanders -
5kg pack
M967-5
Glue Technomelt KS224 for IGM Manual Edgebanders -
25kg pack
M967-25
IGM Vacuum Clamp One-sided, set
M964
IGM Lever Valve for Vacuum Clamp M964
M966-01
IGM Plastic T-splitter for Vacuum Clamp M964
M966-02
IGM nástroje a stroje s.r.o., Ke kopanině 560,
Tuchoměřice, 252 67, Czech Republic, E.U.
+420 220 950 910
,
www.igmtools.com
© 2022 IGM nástroje a stroje s.r.o.