The seller shall not be held responsible for the any condenser damages in the case of 
non-observance of condenser cleaning instructions. 

 

Do not use mechanical agents to quicken the defrosting process!

 

 

6. SERVICE 

6.1. Faults identification and repair 

In case of any difficulties during actuation of the equipment or during its operation, please return to the chapters in 
this manual, which explain the performed operation. This aims to ensure the equipment is properly operated. If you 
still experience difficulties, the following might help you solve the problems. 
 

The equipment is not working... – Make sure that: 

•    The equipment is connected to the power supply. 
•    The Voltage and frequency in the network are compliant with those recommended by the manufacturer, 
115V/60Hz. 
•    The main switch is turned on. 
•    The Thermostat is turned on. 
 

The equipment is operating, but the light is off... – Make sure that: 

•    Light switch is turned on. 
•    Lamp or starting switch of the equipment is not burnt. 
 

Water leakage from under the device 

•    Check whether the unit is properly levelled. 
•    Empty the condensate container. 

 
The equipment does not reach the proper temperature, the light is on... – Make sure that: 

•    The main switch is on. 
•    Temperature setting on the thermostat is properly set. 
•    Thermostat works properly. 
•    The condenser is clean, if necessary – clean the condenser. 
•    Ambient temperature does not exceed 25ºC. 

Figure 7  Cleaning the condenser

 

Summary of Contents for JSCRP

Page 1: ...Pastry Display Cases Models JSCRP and J2SCRP JSCRP J2SCRP Instruction Manual Tel 416 663 3051 Fax 416 663 5793 Toll Free 1 888 408 8819 124 Norfinch Dr Toronto ON M3N 1X1 REFRIGERATION LTD...

Page 2: ...Temperature regulation 8 5 MAINTENANCE 9 5 1 Cleaning and maintenance 12 6 SERVICE 13 6 1 Faults identification and repair 13 6 2 Service 14 List of Figures Figure 1 JSCRP and J2SCRP 4 Figure 2 Level...

Page 3: ...n the environment and the location of the unit 2 2 Description of the unit JSCRP and J2SCRP display cases have static cooling The display case is equipped with automatic condensate evaporation and aut...

Page 4: ...louver 10 ABS sides 11 Control panel 12 Condenser cover DO NOT BLOCK air louver 13 Leveling legs 14 Serial plate 15 Straight front glass 2 3 Technical data Table 1 Technical data Model Voltage V Hz Ph...

Page 5: ...y be turned on after confirmation of the fire protection efficiency with results of measures performed according to binding regulations 3 2 Unit Location Remove cardboard angles and protective foil In...

Page 6: ...disassembled If the user received the unit partially disassembled perform the following operations 1 Place the Fixed shelf grip in perforated frame strip Figure 3 5 2 Mount cross bars Figure3 3 and Fi...

Page 7: ...d aggregate operating cycle may fluctuate This depends on numerous factors such as amount and temperature of products placed in the device and the temperature of the surroundings The equipment should...

Page 8: ...ranty Do not use electric devices inside the product storing chamber Avoid unnecessary opening of doors and leaving them open for a longer period of time 4 1 Temperature regulation The thermostat is t...

Page 9: ...1 sec displays sets the set point more than 3 sec accesses the parameter setting menu enter password 22 mutes the audible alarm buzzer Start Up hold the set mute button for 1 sec RESET current EY set...

Page 10: ...e category of parameters will be on Press SET to display the value associated with the parameter Increase or decrease the value using the UP or DOWN button respectively Press SET to temporarily save t...

Page 11: ...absolute relative temperature for low temperature alarm 0 0 C 50 99 AH absolute relative temperature for high temperature alarm 0 0 C 50 99 Ad temperature alarm delay 0 min 0 199 A4 3rd input configur...

Page 12: ...attention not to damage the temperature sensor It is recommended to make a break in the operation once a month in order to clean the interior naturally defrost the evaporator and clean the condenser I...

Page 13: ...equipment is not working Make sure that The equipment is connected to the power supply The Voltage and frequency in the network are compliant with those recommended by the manufacturer 115V 60Hz The m...

Page 14: ...Each compressor makes certain noises when operating These sounds are made by the aggregate engine and by cooling agent flowing through the circuit This phenomenon constitutes a technical feature of co...