Igloo JSCRP Instruction Manual Download Page 6

 

REFRIGERATION LTD 

 

www.igloorefrigeration.com

 | 

Pastry Cases

 

 

 

High ambient temperatures will cause the compressor to overwork. 

 

Humidity may cause rust, condensation around glass or stainless steel and decrease the efficiency of the 
unit. 

3.3. Connection and start-up 

 

Unpack the unit. 

 

Place the unit on an even and hard base. Then level the unit with the levelling legs. (Figure 2) 

 

 

 
 
 

 

Remove the protection foil from the elements of the unit (e.g. from the inside of the unit, display shelves, 
front bumper) 

 

To securely transport the equipment, the unit may be shipped partially disassembled. If the user received 
the unit partially disassembled, perform the following operations: 
1.

 

Place the Fixed shelf grip in perforated frame strip. (Figure 3/5) 

2.

 

Mount cross bars. (Figure3/3 and Figure 3/4) 

3.

 

Place shelves on fixed grips. 

4.

 

Mount front glass of the display case. 
 

 

 

 

The equipment should be cleaned right after unpacking and before turning the unit on. The unit should be 
cleaned with warm water not exceeding 40°C with a neutral detergent. For washing and cleaning the 
equipment, it is prohibited to use products containing chlorine and sodium varieties, which destroy the 

Figure 2  Leveling legs 

A –Screw the leg in nuts     

Figure 3  Mounting wire 
shelves 

1 –  Perforated frame stip 
2 –  Plastic wire shelf 
3 –  Cross bar with lamp 
4 –  Cross bar  
5 –  Fixed shef grip 

Summary of Contents for JSCRP

Page 1: ...Pastry Display Cases Models JSCRP and J2SCRP JSCRP J2SCRP Instruction Manual Tel 416 663 3051 Fax 416 663 5793 Toll Free 1 888 408 8819 124 Norfinch Dr Toronto ON M3N 1X1 REFRIGERATION LTD...

Page 2: ...Temperature regulation 8 5 MAINTENANCE 9 5 1 Cleaning and maintenance 12 6 SERVICE 13 6 1 Faults identification and repair 13 6 2 Service 14 List of Figures Figure 1 JSCRP and J2SCRP 4 Figure 2 Level...

Page 3: ...n the environment and the location of the unit 2 2 Description of the unit JSCRP and J2SCRP display cases have static cooling The display case is equipped with automatic condensate evaporation and aut...

Page 4: ...louver 10 ABS sides 11 Control panel 12 Condenser cover DO NOT BLOCK air louver 13 Leveling legs 14 Serial plate 15 Straight front glass 2 3 Technical data Table 1 Technical data Model Voltage V Hz Ph...

Page 5: ...y be turned on after confirmation of the fire protection efficiency with results of measures performed according to binding regulations 3 2 Unit Location Remove cardboard angles and protective foil In...

Page 6: ...disassembled If the user received the unit partially disassembled perform the following operations 1 Place the Fixed shelf grip in perforated frame strip Figure 3 5 2 Mount cross bars Figure3 3 and Fi...

Page 7: ...d aggregate operating cycle may fluctuate This depends on numerous factors such as amount and temperature of products placed in the device and the temperature of the surroundings The equipment should...

Page 8: ...ranty Do not use electric devices inside the product storing chamber Avoid unnecessary opening of doors and leaving them open for a longer period of time 4 1 Temperature regulation The thermostat is t...

Page 9: ...1 sec displays sets the set point more than 3 sec accesses the parameter setting menu enter password 22 mutes the audible alarm buzzer Start Up hold the set mute button for 1 sec RESET current EY set...

Page 10: ...e category of parameters will be on Press SET to display the value associated with the parameter Increase or decrease the value using the UP or DOWN button respectively Press SET to temporarily save t...

Page 11: ...absolute relative temperature for low temperature alarm 0 0 C 50 99 AH absolute relative temperature for high temperature alarm 0 0 C 50 99 Ad temperature alarm delay 0 min 0 199 A4 3rd input configur...

Page 12: ...attention not to damage the temperature sensor It is recommended to make a break in the operation once a month in order to clean the interior naturally defrost the evaporator and clean the condenser I...

Page 13: ...equipment is not working Make sure that The equipment is connected to the power supply The Voltage and frequency in the network are compliant with those recommended by the manufacturer 115V 60Hz The m...

Page 14: ...Each compressor makes certain noises when operating These sounds are made by the aggregate engine and by cooling agent flowing through the circuit This phenomenon constitutes a technical feature of co...

Reviews: