background image

en

16

User manual INNOVA

www.igloo.pl

• 

Place the plug of the connecting cable directly in plug-in socket (it is forbidden to connect the device by 

means of extension cords or dividers!)

• 

Turn on the main switch Fig.2/2 (p.14), which activates the thermostat, and then aggregate of the device

• 

Set the temperature on thermostat control panel Fig.2/1 (p.14) (thermostat service details on p.21 or 22)

• 

Turn on the lighting switch Fig.2/3 (p.14)

4. EXPLOITATION

Temperature of the cooled space and aggregate operating cycle may fluctuate. They depend on numerous factors, 

such as amount and temperature of products placed in the device and temperature of the surroundings.

The device should be placed in a dry and well-ventilated place, ensuring proper air exchange (distance between the 

wall and the device – min. 10 cm), out of sunlight, kept far from heat sources and devices enforcing air flow (ceiling 

and portable ventilators, blow-in heaters). The device functions properly in a room, where temperature falls within 

appropriate climatic class stated on the data plate. The operation of the device may worsen when it shall operate in 

temperature lower or higher than the stated temperature range.

      

 Remarks and indications

•  It is necessary to properly level the rack, which will prevent the device from noisy operation and will ensure 

proper outflow of the water (condensate) during defrosting.

•  After transporting the device, wait about 2 hours before its actuation.

•  In order to ensure proper conditions for the stored products, do not load the shelves completely. It is neces-

3. PREPARING THE DEVICE FOR EXPLOITATION

3.1. Requirements concerning the place of installation

• 

Verify whether the cross section of feeding conduits is proper for power consumption of the installed 

device.

• 

It is forbidden to connect the device by extension rods or dividers.

• 

The device should be connected to the separate, properly made electric circuit with plug-in socket with 

• 

   protecting pin (according to PBUE /Regulations concerning Electric Equipment Construction/)

3.2. Connection and actuation

• 

Unpack the device and remove the wooden platform from the basis Fig.3 (p.15)

• 

The device should be placed on an even and on a sufficiently hard base, and then level it with the help of 

levelling feet.

•  Remove the protection foil from the elements of the device (f. ex. from the inside of the device, display she-

lves, front fender beam)

•  If the user shall obtain a device partially disassembled to secure it during transportation, perform the following 

operations:

1.  Fix hooks in frame rails Fig.3 (p.15)

2.  Place shelves and/or baskets on hooks Fig.3 (p.15)

3.  (Concerns the devices with internal aggregate) Place the condensate container on the basis of the aggregate, 

under water outflow hose (does not concern devices with automatic condensate evaporation) Fig.5 (p.18) 

4.  (Concerns the devices to be mounted on central aggregate) Defrosting water outflow is located under the bot-

tom of the body (about 10mm from the back of the rack, in the middle part of the body), which needs toallow 

water outflow to the sewage grit

• 

The first cleaning of the device

 should be provide right after unpacking, and before turning it on. The unit 

should be cleaned with water at a temperature not exceeding 40°C with a neutral detergent. For washing 

and cleaning the equipment it is prohibited to use products containing chlorine and sodium varieties, which 

destroy the protective layer and components of the device! Any residue of adhesives or silicone on metal 

elements should be  removed only with extraction naphtha (not applicable to items made of plastic !). Do 

not use other organic solvents.

When cleaning the unit is prohibited to use water jet. The unit should be cleaned with a wet rag.

After installation of the device at the destination place it  should be left to rest for at least 2 hours before 

turning it on (for devices with built in compressor) to set the level of refrigerant in order to prevent problems 

with starting up the aggregate.

WARNING: Keep out the cooling circuit from damage!

Summary of Contents for INNOVA series

Page 1: ...uipped in dynamic cooling automatic condensation evaporation and defrosting The display case is also equipped with an electronic thermostat which works optionally with the temperature registration mod...

Page 2: ...m 5 Internal surfaces with glass shelf 6 Suction DO NOT BLOCK the vents 7 Airflow DO NOT BLOCK the vents 8 Plinth block 9 Legs used to level the unit 10 Control panel thermostat switches Rys 2 Control...

Page 3: ...clean 15 Bumbon Silicone element protecting glass components from moving and allowing for better grip Do not dama ge during operation and maintenance 16 Aluminium profile glass shelf support with bac...

Page 4: ...with plug in socket with protecting pin according to PBUE Regulations concerning Electric Equipment Construction 3 2 Connection and actuation Unpack the device and remove the wooden platform from the...

Page 5: ...chapter 7 p 20 and 21 The basic aim of a thermostat is to control the cooling aggregate to obtain the set temperature within the device and maintain it within the determined temperature ranges The pro...

Page 6: ...out switch on the open close lock button on the control panel at the back of the unit and then press the release lock while slightly pressing against the wooden casing for the lock to let go To draw...

Page 7: ...ent temperature does not exceed 25 C Enough time has passed for products to be cooled Ventilation holes of the device are not blocked This concerns the IGLOO thermostat thermostat displays C0 or C1 or...

Page 8: ...ssary clean the condenser Condenser ventilator is working properly Ambient temperature does not exceed 25 C The device is working too loud Make sure that The device is standing stably and is properly...

Page 9: ...decrease the temperature to the desired value The preview shall finish automatically after about 3 seconds Manual defrosting switch No 2 enables to initiate the defrosting cycle at any moment when th...

Page 10: ...perature inside the device is displayed decimal places displayed after the comma SETTING THE DESIRED TEMPERATURE press for 1 second leading value shall be displayed on the screen increase or decrease...

Page 11: ...en 23 User manual INNOVA www igloo pl Correspondence Stary Wi nicz 289 32 720 Nowy Wi nicz Poland NIP 868 000 50 40 Tel 48 14 662 19 10 fax 48 14 662 19 12 e mail info igloo pl www igloo pl...