background image

en

18

User manual INNOVA

www.igloo.pl

Fig.5 Cleaning the condenser

Elements of device can corrode when improper used and maintenance. To avoid that please 

follow the rules:

• Do not allow contact of the surface of the device with substances  containing chlorine and / or baking 

soda in different varieties, which destroy the protective layer and components of the device (also 

includes various stainless steel)

Elements of device can corrode when improper used and maintenance. To avoid that please 

follow the rules:

• Do not allow contact of the surface of the device with substances  containing chlorine and / or baking 

soda in different varieties, which destroy the protective layer and components of the device (also 

includes various stainless steel)

During maintenance services it is necessary to pay attention not to damage the data place of the 

device Fig.13 (p.10), which contains significant information for servicing organs and waste removal 

companies.

The device uses a retractable front panel system with an electromagnetic lock blocking the slide. 

To slide the glass out, switch on the open/close lock button on the control panel at the back of 

the unit, and then press the release lock, while slightly pressing against the wooden casing for 

the lock to let go. To draw the front glass back in, lightly press near the lock for the lock button to 

switch on. To completely prevent from opening the front glass by unauthorized persons, turn off 

the power of the electromagnet on the operating panel.

While drawing the glass front back in, press against it slightly where the lock is, and not in the upper part!

It is recommended to make a break in the exploitation of the device 

once a month

 in order to clean its interior, 

naturally defrost the evaporator and clean the condenser.

It is essential to keep the 

condenser of the device

 clean. Dirt may hinder the heat exchange, causing mainly increase in electric 

energy consumption and may cause damage of aggregate compressor. 

In order to clean the condenser it is necessary to unscrew the sheet metal screws and pull the wind brace out of catch by lifting it 

up. Clean condenser lamellas with help of soft brush or paint brush. If the condenser is extremely dirty (blocking of lamellas) it is 

indicated to use vacuum cleaner or compressed nitrogen to suck / blow the dirt from between lamellas.

Summary of Contents for INNOVA series

Page 1: ...uipped in dynamic cooling automatic condensation evaporation and defrosting The display case is also equipped with an electronic thermostat which works optionally with the temperature registration mod...

Page 2: ...m 5 Internal surfaces with glass shelf 6 Suction DO NOT BLOCK the vents 7 Airflow DO NOT BLOCK the vents 8 Plinth block 9 Legs used to level the unit 10 Control panel thermostat switches Rys 2 Control...

Page 3: ...clean 15 Bumbon Silicone element protecting glass components from moving and allowing for better grip Do not dama ge during operation and maintenance 16 Aluminium profile glass shelf support with bac...

Page 4: ...with plug in socket with protecting pin according to PBUE Regulations concerning Electric Equipment Construction 3 2 Connection and actuation Unpack the device and remove the wooden platform from the...

Page 5: ...chapter 7 p 20 and 21 The basic aim of a thermostat is to control the cooling aggregate to obtain the set temperature within the device and maintain it within the determined temperature ranges The pro...

Page 6: ...out switch on the open close lock button on the control panel at the back of the unit and then press the release lock while slightly pressing against the wooden casing for the lock to let go To draw...

Page 7: ...ent temperature does not exceed 25 C Enough time has passed for products to be cooled Ventilation holes of the device are not blocked This concerns the IGLOO thermostat thermostat displays C0 or C1 or...

Page 8: ...ssary clean the condenser Condenser ventilator is working properly Ambient temperature does not exceed 25 C The device is working too loud Make sure that The device is standing stably and is properly...

Page 9: ...decrease the temperature to the desired value The preview shall finish automatically after about 3 seconds Manual defrosting switch No 2 enables to initiate the defrosting cycle at any moment when th...

Page 10: ...perature inside the device is displayed decimal places displayed after the comma SETTING THE DESIRED TEMPERATURE press for 1 second leading value shall be displayed on the screen increase or decrease...

Page 11: ...en 23 User manual INNOVA www igloo pl Correspondence Stary Wi nicz 289 32 720 Nowy Wi nicz Poland NIP 868 000 50 40 Tel 48 14 662 19 10 fax 48 14 662 19 12 e mail info igloo pl www igloo pl...

Reviews: